VDE SAFETY INTERLOCK AGX (GX) SWITCH SMALL SIZE & LIGHT FORCE SWITCHES FEATURES Constructed with dual restoration springs and double cut-off for safety Contact gap of greater than 4mm (Conforming to IEC 950) As for 3 Form A type, combination of power contact and signal contact is available UL/CSA/SEMKO/TV/VDE approved 1a TYPICAL APPLICATIONS Door interlock of copiers, printers, facsimiles Door interlock of other compact appliances 3a 2a ORDERING INFORMATION Ex. AGX F Capacity and Product Name Contact arrangement Terminals Contact mounting method GX 1: 1 Form A Power switching contact 0: Standard type 10.1 A 5: .250 Quick-connect terminal F: Cadmium free 2: 2 Form A Power switching contact (Snap-in mounting) (O.T. 2 mm) 3: 3 Form A Power switching contact 6: .250 Quick-connect terminal 6: 1 Form A Power switching contact and (O.T. 4 mm) 2 Form A Signal switching contact 7: 2 Form A Power switching contact and 1 Form A Signal switching contact PRODUCT TYPES Switching timing Overtravel (O.T.) Rating Contact arrangement Part number Min. mm 1st ON 2nd ON 1 Form A Power switching contact AGX105F 2 2 Form A Power switching contact AGX205F 1 Form A Power switching contact AGX106F 2 Form A Power switching contact AGX206F 3 Form A 3a power AGX306F Power switching contact Standard type 1 Form A 10.1A 250V AC Power switching contact 4 1a power 2a signal AGX606F 2 Form A 3 Form A Signal switching contact 2 Form A Power switching contact 2a power 1a signal AGX706F 1 Form A Signal switching contact All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.AGX SPECIFICATIONS 1. Contact rating Resistive load Motor load* (EN61058-1) Number of contact (cos 1) (cos 0.6) 10.1A 125V AC Standard type 10.1A 250V AC 3A 125V AC power switching contact 6A 30V DC 3A 250V AC 3A 48V DC (3 Form A type only) 0.1A 48V DC Signal switching contact Contact Low-level circuit: (3 Form A only) 1mA 5V DC Remark: Motor load designates an inrush current switching capability of 6 times the indicated rating 2. Characteristics Type Standard type Mechanical 6 10 min. (at 60 cpm) Expected 5 life Electrical 10 (at 20 cpm, operating speed: 10mm/sec.) (at 10.1A 250V AC) Insulation resistance 100M at 500V DC Between terminals 2,000Vrms for 1 minute Dielectric Between terminals and other exposed 2,500Vrms for 1 minute strength metal parts Between terminals and ground 2,000Vrms for 1 minute Initial contact resistance 100m Max. (by voltage drop at 1A, 6 to 8V DC) Temperature rise (terminal portion) Initial 45 deg. Max., After test 55 deg. Max. Vibration resistance 10 to 55Hz at single amplitude of 0.75mm 2 Shock resistance Min. 294m/s 49N for 1 minute Actuator strength (For operating direction) Min. 147N Tensile terminal strength (Pulling for operating direction) Allowable operating speed Min. 10 to 300mm/second Allowable operating cycle rate 60 cpm Temperature resistance 40C to 45C: 48 hours, +80C to +90C: 48 hours Ambient temperature 25C to +85C (Not freezing nor condensing) Flame retardancy Min. UL 94V-1 Tracking resistance (CTI) Min. 175 Contact material AgCuO alloy *Remark: Test condition and judgement are complying with JIS C4505, EN61058 and UL1054. 3. Operating characteristics Total operating force Operating Free position Operating Total travel Over travel Contact (T.F) Part number force (O.F.) (F.P.) Max. position (O.P.) position (O.T.) Min. arrangement Max. Push button Max. mm mm (T.T.P.) mm mm position: 2.4mm 1 Form A AGX105 3.92 N 4.90 N 8 4.80.4 2.4 2.0 2 Form A AGX205 3.92 N 4.90 N 8 4.80.4 2.4 2.0 Standard type 1 Form A AGX106 3.92 N 6.86 N 10 7.00.4 2.4 4.0 10.1A 250V AC 2 Form A AGX206 3.92 N 6.86 N 10 7.00.4 2.4 4.0 3 Form A AGX306 2.94 N 5.88 N 10 7.00.4 2.4 4.0 Remark: With the 3 Form A type sequence operation type, the specications for the contact where the operation position turns ON rst are as per the above table. However, the specications for the contact where the operation position turns ON later are delayed by approximatery 0.8 mm compared with the above table. All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.