AGX (GX) Compact Size Fail-safe Door Interlock Switches SWITCHES FEATURES 14 mm in depth Contact gap is greater than 4mm (Conforming to 14 mm IEC60950-1) in depth Ensure more than 4 mm insulation distance between open contacts 1 Form A Constructed with dual restoration springs and double cut- 27 off for safety 14.6 Combination of power contact and signal contact is available (for 3 Form A type) TYPICAL APPLICATIONS Ofce equipment: Copiers, Printers 3 Form A 2 Form A Power supply devices (Unit: mm) RoHS compliant ORDERING INFORMATION AGX 0 F Capacity and mounting method Terminals Contact arrangement F: Cadmium free 0: 10.1 A Snap-in mounting 5: .250 Quick-connect terminal 1: 1 Form A Power switching contact (OT 2 mm) 2: 2 Form A Power switching contact 6: .250 Quick-connect terminal 3: 3 Form A Power switching contact (OT 4 mm) 6: 1 Form A Power switching contact and 2 Form A Signal switching contact 7: 2 Form A Power switching contact and 1 Form A Signal switching contact PRODUCT TYPES Sequence operation Type Overtravel (OT) Contact form Terminal Part number 1st ON 2nd ON 1 Form A AGX105F Min. 2 mm 2 Form A AGX205F 1 Form A AGX106F 2 Form A AGX206F Standard type .250 Quick-connect 3 Form A Power 3 Forma A power AGX306F 10.1A 250V AC terminal Min. 4 mm 1 Form A Power 1 Form A power 2 Form A signal AGX606F 3 Form A 2 Form A Signal 2 Form A Power 2 Form A power 1 Form A signal AGX706F 1 Form A Signal AECTB19E 201408-T 1AGX (GX) Interlock Switches CONSTRUCTION (Dual safety construction) Dual restoration spring Double cut-off type 2mm min. 4mm or more contact gap (2mm or more on one side) 2 .250 Quick-connect terminal SPECIFICATIONS Contact rating Contact type Resistive load (cos 1) Motor load* (EN61058-1) (cos 0.6) 10.1A 125V AC 10.1A 250V AC 3A 125V AC Standard type power switching contact 6A 30V DC 3A 250V AC 3A 48V DC (3 Form A type only) 0.1A 48V DC Signal switching contact (3 Form A only) Contact Low-level circuit: 1mA 5V DC Note: Motor load of EN61058-1 designates an inrush current switching capability of 6 times the indicated rating Characteristics Item Specications 6 Mechanical 10 min. (at 60 cpm) Expected life 5 Electrical 10 (at 10.1A 250V AC) (at 20 cpm, operating speed: 10mm/sec.) Insulation resistance 100M (at 500V DC) Between non-continuous terminals 2,000Vrms for 1 minute Between each terminal and other Dielectric strength 2,500Vrms for 1 minute exposed metal parts Between each terminal and ground 2,000Vrms for 1 minute Contact resistance Initial Max. 100m (by voltage drop at 1A, 6 to 8V DC) Temperature rise (terminal portion) Initial Max. 45C, After test Max. 55C Vibration resistance 10 to 55Hz at single amplitude of 0.75mm (Contact opening: 1 msec. max.), double amplitude of 1.5mm 2 Shock resistance Min. 294m/s (Contact opening: 1 msec. max.) Actuator strength 49N for 1 minute (For operating direction) Tensile terminal strength Min. 147N (Pulling for operating direction) Allowable operating speed 10 to 300mm/sec. Allowable operating cycle rate 60 cpm Heat and cold resistance resistance 40C to 45C: 48 hours, +80C to +90C: 48 hours Ambient temperature 25C to +85C no freezing and condensing Flame retardancy UL94V-0 Tracking resistance (CTI) Min. 175 Contact specications Contact material AgCuO alloy Unit weight Approx. 15 g Protection grade IP40 Note: Test condition and judgement are complying with NECA C4505, EN61058-1 and UL1054. Operating characteristics Standard type Total operating Force Part number Operating Force (OF) (TF) Max. Free Position (FP) Operating Position Total Travel Position Over Travel (OT) (Contact arrangement) Max. Push button position: Max. (OP) (TTP) Min. 2.4mm AGX105F (1 Form A) 3.92 N 4.90 N 8 mm 4.80.4 mm 2.4 mm 2.0 mm AGX205F (2 Form A) 3.92 N 4.90 N 8 mm 4.80.4 mm 2.4 mm 2.0 mm AGX106F (1 Form A) 3.92 N 6.86 N 10 mm 7.00.4 mm 2.4 mm 4.0 mm AGX206F (2 Form A) 3.92 N 6.86 N 10 mm 7.00.4 mm 2.4 mm 4.0 mm AGX306F (3 Form A) 2.94 N 5.88 N 10 mm 7.00.4 mm 2.4 mm 4.0 mm Note: With the 3 Form A sequence operation type, the specications for the contact where the operation position turns ON rst are as per the above table. However, the specications for the contact where the operation position turns ON later are delayed by approximatery 0.8 mm compared with the above table. AECTB19E 201408-T 2