1 Form A 5A slim power relay PA-N RELAYS complies with IEC61010 reinforced insulation FEATURES TYPICAL APPLICATIONS 1. High density mounting 1. Output relays for programmable 5mm(W) 20mm(L) 12.5mm(H) controllers and temperature .197inch(W) .787inch(L) controllers .492inch(H) 2. Industrial equipment, ofce 2. Low operating power equipment Nominal operating power: 110mW 3. Measuring devices and test 3. Complies with IEC61010 reinforced equipment insulation standards 4. Long Insulation distance RoHS compliant Clearance: 5.29mm .208inch Creepage distance: 5.35mm .211inch (Between contact and coil) Protective construction: Sealed type 3,000 V breakdown voltage and (RTIII) 6,000V surge breakdown voltage 5. Complies with Standard for Hazardous Location (ANSI/ISA 12.12.01) ORDERING INFORMATION APAN 3 1 Contact arrangement 3: 1 Form A (Bifurcated) Terminals and Nominal operating power 1: PC board terminal (110 mW) Nominal coil voltage (DC) 03: 3V, 4H: 4.5V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V Note: Certified by UL/C-UL and TV TYPES Contact arrangement Nominal coil voltage Part No. 3 V DC APAN3103 4.5 V DC APAN314H 5 V DC APAN3105 6 V DC APAN3106 1 Form A 9 V DC APAN3109 12 V DC APAN3112 18 V DC APAN3118 24 V DC APAN3124 Standard packing: Tube: 25 pcs. Case: 1,000 pcs. * Terminal sockets available. ASCTB368E 201604-T 1 NewPA-N (APAN3) RATING 1. Coil data Nominal operating Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage current voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power (at 20C 68F) 10% (at 20C 68F) 3 V DC 36.7 mA 82 4.5 V DC 24.4 mA 184 5 V DC 22.0 mA 227 70%V or less of 5%V or more of 6 V DC 18.3 mA 327 120%V of nominal voltage* nominal voltage* 110mW nominal voltage 9 V DC 12.2 mA 736 (Initial) (Initial) 12 V DC 9.2 mA 1,309 18 V DC 6.1 mA 2,945 24 V DC 4.6 mA 5,236 Note: *Pulse drive (JIS C 5442) 2. Specications Characteristics Item Specications Arrangement 1 Form A (Bifurcated) Contact Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A) Contact material AgNi type + Au Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC Max. switching power (resistive load) 1,250 VA, 150 W Max. switching voltage 250 V (AC), 110 V (DC) (0.4 A) Rating Max. switching current 5 A (AC, DC) Nominal operating power 110 mW 1 Min. switching capacity (Reference value)* 1 mA 5 V DC Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.) Breakdown voltage (Initial) Between contact and coil 3,000 Vrms for 1min. (Detection current: 10mA.) Surge breakdown voltage (Initial) Electrical 6,000 V 2 (Between contacts and coil)* characteristics Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (Initial) Release time (at nominal voltage) (at 20C 68F) Max. 5 ms (excluding contact bounce time and without diode) (Initial) 2 Functional Min. 147 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive Min. 980 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 3.5 mm 7 Mechanical Min. 210 (at 180 times/min.) 5 Expected life Min. 10 (3 A 250 V AC, 30 V DC, resistive load) Electrical 4 4 Min. 510 (5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)* Ambient temperature: 40C to 90C 40F to 194F 3 Conditions for operation, transport and storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Conditions 4 Max. operating speed 20 times/min. (at nominal switching capacity)* Unit weight Approx. 3 g .15 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. Operating frequency of 5 A 250 V AC is 6 times/min. (ON : OFF = 1 s : 9 s) ASCTB368E 201604-T 2