AQ-GVDE 1A and 2A space saving PC AQ-G RELAYS board terminal type AQ-G 4.5 max. FEATURES .177 max. 24.5 max965 max. 1. Space saving, Vertical size with a 5. Snubber circuit integrated 13.5 max. maximum thickness of 4.5 mm. The snubber circuit is integrated to .531 max. Mounting space has been reduced to prevent malfunction caused by the rapid 30% (compared to conventional SSRs) rise of voltage on the output side, such as while meeting high density PC board inductive load and current. mounting requirements. 2. 1A and 2A load types available 4.5 max177 max. 24.5 max. 3. Zero-cross type and Non zero-cross .965 max. type available 4. High dielectric strength of 20.5 max. 3,000V AC .807 max. (between input and output) mm inch TYPES TYPICAL APPLICATIONS Load Manufacturing equipment Type Load voltage Input voltage Part No. current NC machines 5 V DC AQG12105 Injection molders 1A 75 to 264 V AC 12 V DC AQG12112 Robots 24 V DC AQG12124 Air conditioners Zero-cross 5 V DC AQG22105 Computers 2A 75 to 264 V AC 12 V DC AQG22112 24 V DC AQG22124 5 V DC AQG12205 1A 75 to 264 V AC 12 V DC AQG12212 24 V DC AQG12224 Non zero- cross 5 V DC AQG22205 2A 75 to 264 V AC 12 V DC AQG22212 24 V DC AQG22224 ORDERING INFORMATION Ex. AQG12105 Load current Load voltage Type Input voltage 1: 1 A 2: 75 to 264 V AC 1: Zero-cross (3,000 V) 05: 5 V DC 2: 2 A 2: Non zero-cross (3,000 V) 12: 12 V DC 24: 24 V DC (Note) Standard packing: Carton 20 pcs., Case 500 pcs. ds 61611 en aqg: 010611D 1AQ-G SPECIFICATIONS 1. Ratings (at 20 C 68 F, Input voltage ripple: 1% or less) 1) Zero-cross type Part No. Item Type Remarks AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124 Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC Input impedance Approx. 0.3k Approx. 0.8k Approx. 1.6k Approx. 0.3k Approx. 0.8k Approx. 1.6k Input Drop-out side 1 V voltage, min. Reverse voltage 3 V Max. load current 1 A AC 2 A AC Load voltage 75 to 264 V AC Frequency 45 to 65 Hz Non-repetitive In one cycle 8 A 30 A Load surge current at 60 Hz side Max. OFF-state 1.5 mA (applied 200 V) leakage current Max. ON-state at Max. carrying 1.6 V voltage drop current Min. load current 20 mA 2) Non zero-cross type Part No. Item Type Remarks AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224 Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC Input impedance Approx. 0.3k Approx. 0.8k Approx. 1.6k Approx. 0.3k Approx. 0.8k Approx. 1.6k Input Drop-out side 1 V voltage, min. Reverse voltage 3 V Max. load current 1 A AC 2 A AC Load voltage 75 to 264 V AC Frequency 45 to 65 Hz Non-repetitive In one cycle 8 A 30 A Load surge current at 60 Hz side Max. OFF-state 1.5 mA (applied 200 V) leakage current Max. ON-state at Max. carrying 1.6 V voltage drop current Min. load current 20 mA 2. Characteristics (at 20C 68 F, Input voltage ripple: 1% or less) Item Zero-cross type Non zero-cross type Remarks Operate time max. (1/2 cycle of voltage sine wave) + 1 ms 1 ms Release time, max. (1/2 cycle of voltage sine wave) + 1 ms 9 Insulation resistance, min. 10 between input and output Using 500 V DC megger Breakdown voltage 3,000 Vrms between input and output Initial for 1 min. Vibration resistance 10 to 55 Hz double amplitude of 0.75 mm X, Y, Z axes 2 Shock resistance 1,000 m/s X, Y, Z axes Non-condensing at low Ambient temperature 30 C to +80C 22F to +176F temperatures Storage temperature 30 C to +100 C 22F to +212 F Non zero-cross turn ON, Operational method Zero-cross (Turn-ON and Turn-OFF) Zero-cross turn OFF 2 ds 61611 en aqg: 010611D