TV Rheinland
AQ-K
(Breakdown voltage 2,500V) (Breakdown voltage 4,000V)
Slim prole SSR
with heat sink mountable
AQ-K RELAYS
on DIN rail
FEATURES APPLICATIONS
1. Combined with heat sink for vertical 1. Molding machine (heater control)
prole 2. Temperature controlled bath (heater
Helps to save space on control panel control)
2. Dielectric voltage of 2,500V or 3. Printing machine (heater control)
4,000V 4. Machine tool (motor control)
3. Both screw-on installation or one-
touch DIN-rail installation available
4. Includes operation LED (red)
5. Built-in varistor
RoHS compliant
ORDERING INFORMATION
AQK
Load current
1: 15 A
2: 25 A
Load voltage
2: 75 to 250 V AC
Type
1: Zero-cross type (2,500 V)
3: Zero-crosst ype (4,000 V)
Input voltage
1: 4.5 to 30 V DC
TYPES
Type Load current Load voltage Input voltage Breakdown voltage Part No.
4.5 to 30 V DC 2,500 V AC AQK1211
15 A 75 to 250 V AC
4.5 to 30 V DC 4,000 V AC AQK1231
Zero-cross
4.5 to 30 V DC 2,500 V AC AQK2211
25 A 75 to 250 V AC
4.5 to 30 V DC 4,000 V AC AQK2231
Standard packing: Carton 10 pcs., Case: 60 pcs.
ASCTB85E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/eAQ-K
RATING
1. Ratings (Ambient temperature: 20C 68F, Input ripple: 1% or less)
1) 10 A type
Item Type AQK1211 AQK1231 AQK2211 AQK2231 Remarks
Input voltage 4.5 to 30 V DC
1
Input side Input current, max. 10 mA *
Drop-out voltage, min. 1 V
2 2
Max. load current 15 A* 25 A* Ta = Max. 40C 104F
Load voltage 75 to 250 V AC
Frequency 45 to 65 Hz
3 3
Load side Non-repetitive surge current 150 A* 250 A* In one cycle at 60 Hz
Max. OFF-state leakage current 9 mA at 60 Hz, 200 V AC
Max. ON-state voltage drop 1.6 V at max. carrying current
4
Min. load current 100 mA*
Notes: *1. Refer to REFERENCE DATA 3. Input current vs. input voltage.
*2. Refer to REFERENCE DATA 1. Load current vs. ambient temperature.
*3. Refer to REFERENCE DATA 2. Non-repetitive surge current vs. carrying time.
*4. When the load current is less than the rated minimum load current, please refer to Cautions for Use of SSR.
2. Characteristics (Ambient temperature: 20C 68F, Input ripple: 1% or less)
Part No.
AQK1211 AQK1231 AQK2211 AQK2231 Remarks
Item
Operate time, max. 1/2 cycle of voltage sine wave + 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Breakdown voltage 2,500 V AC 4,000 V AC 2,500 V AC 4,000 V AC
Insulation resistance, min., Initial 100 M between input, output and case at 500V DC
Vibration resistance 10 to 55 Hz at double amplitude of 0.75 mm 1 hour for X, Y, Z axes
2
Shock resistance Min. 294 m/s 10 minutes for X, Y, Z axes
Ambient temperature 30C to +80C 22F to +176F Non-condensing at low temperatures
Storage temperature 35C to +100C 31F to +212F
Operational method Zero-cross (Turn-ON and Turn-OFF)
REFERENCE DATA
1. Load current vs. ambient temperature 2. Non-repetitive surge current vs. carrying 3. Input current vs. input voltage characteristics
characteristics time characteristics
(15 A, 25 A type)
30 15
300
250
25
25A type
20 10
200
25A type
15A type
15A type
15 150
10 100 5
5 50
0
0 0
30 0 20 40 60 80 12 345 710 20 304050 70 100 015015202530
Ambient temperature, C No. of cycles at 60 Hz Input voltage, V
4-(1) Load current when contact mounted vs. 4-(2) Load current when contact mounted vs.
ambient temperature characteristics ambient temperature characteristics
Tested sample: AQK1211, AQK1231 Tested sample: AQK2211, AQK2231
25 25
1 pc.
1 pc.
20 20
3 pcs.
3 pcs. 18
16
15 15
12
8 pcs.
11
10 10
9A
8A
8 pcs.
6A
5 5
5.5A
0 0
-30 0 20 40 60 80 100 -30 0 20 40 60 80 100
Ambient temperature, C
Ambient temperature, C
ASCTB85E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
Load current, A Load current, A
Non-repetitive surge current, A
Load current, A
Input current, mA