HE 1 Form A (AQV25) TESTING
(Standard type) (Reinforced type, excluding AQV256H)
Both low on-resistance and
good cost-performance
HE 1 Form A
achieved.
(AQV25)
6.4
FEATURES TYPICAL APPLICATIONS
8.8
.252
.346
1. Wide variation of 40V, 60V, 100V, Measuring instruments
3.9
.154
200V, 250V, 400V, 600V, 1,000V and Data communication equipment
1,500V load voltage Telephone equipment
6.4
8.8
.252
2. Low on-resistance of typ. 0.6 Automatic meter reading device
.346
3.6
(AQV251)
.142
Height includes
3. Reinforced insulation type of 5,000V
standoff
I/O isolation available
mm inch
1 6
2 5
3 4
RoHS compliant
TYPES
Part No.
Output rating* Packing quantity
Through hole
Surface-mount terminal
terminal
I/O isolation Package
Tape and reel packing style
Load Load
Tube packing style Tube Tape and reel
Picked from the Picked from the
voltage current
1/2/3-pin side 4/5/6-pin side
40 V 500 mA AQV251 AQV251A AQV251AX AQV251AZ
60 V 400 mA AQV252 AQV252A AQV252AX AQV252AZ
100 V 350 mA AQV255 AQV255A AQV255AX AQV255AZ
200 V 250 mA AQV257 AQV257A AQV257AX AQV257AZ
1,500V
1 tube contains:
250 V 200 mA AQV253 AQV253A AQV253AX AQV253AZ
AC/DC 50 pcs.
400 V 150 mA DIP6-pin AQV254 AQV254A AQV254AX AQV254AZ 1,000 pcs.
dual use 1 batch contains:
1,000 V 30 mA AQV259 AQV259A AQV259AX AQV259AZ
500 pcs.
1,500 V 20 mA AQV258 AQV258A AQV258AX AQV258AZ
250 V 200 mA AQV253H AQV253HA AQV253HAX AQV253HAZ
Reinforced
400 V 150 mA AQV254H AQV254HA AQV254HAX AQV254HAZ
5,000V
600 V 130 mA AQV256H AQV256HA AQV256HAX AQV256HAZ
*Indicate the peak AC and DC values.
Note: The surface mount terminal indicator A and the packing style indicator X or Z are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25C 77F)
Type of
Sym-
Item connec- AQV251(A) AQV252(A) AQV255(A) AQV257(A) AQV253(A) AQV254(A) AQV259(A) AQV258(A) AQV253H(A) AQV254H(A) AQV256H(A) Remarks
bol
tion
LED forward current IF 50 mA
LED reverse voltage VR 5 V
f = 100 Hz,
Peak forward current IFP 1 A
Duty factor +0.1%
Power dissipation Pin 75 mW
Load voltage
VL 40V 60V 100V 200V 250V 400V 1,000V 1,500V 250V 400V 600V
(peak AC)
A 0.5A 0.4A 0.35A 0.25A 0.2A 0.15A 0.03A 0.02A 0.2A 0.15A 0.13A
A connection:
Continuous load
IL B 0.7A 0.6A 0.45A 0.35A 0.3A 0.18A 0.04A 0.025A 0.3A 0.18A 0.14A Peak AC, DC
current
B, C connection: DC
C 1.0A 0.8A 0.70A 0.5A 0.4A 0.25A 0.05A 0.04A 0.4A 0.25A 0.16A
A connection: 100 ms
Peak load current Ipeak 1.8A 1.5A 1.0A 0.75A 0.6A 0.5A 0.09A 0.06A 0.6A 0.5A 0.4A
(1 shot) VL = DC
Power dissipation Pout 360 mW
Total power dissipation PT 410 mW
I/O isolation voltage Viso 1,500 V AC 5,000 V AC
Non-condensing at
Operating Topr 40C to +85C 40F to +185F
Temperature
low temperatures
limits
Storage Tstg 40C to +100C 40F to +212F
ASCTB143E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
New
Output InputHE 1 Form A (AQV25)
2. Electrical characteristics (Ambient temperature: 25C 77F)
Type of
Sym-
Item con- AQV251(A) AQV252(A) AQV255(A) AQV257(A) AQV253(A) AQV254(A) AQV259(A) AQV258(A) AQV253H(A) AQV254H(A) AQV256H(A) Condition
bol
nection
Typical 0.9 mA 1.4 mA
LED operate current IFon IL = Max.
Maximum 3 mA
Minimum 0.4 mA
LED turn off current IFoff IL = Max.
Typical 0.8 mA 1.3 mA
Typical 1.25 V (1.14 V at IF = 5 mA)
LED dropout voltage VF IF = 50 mA
Maximum 1.5 V
IF = 5 mA
Typical 0.6 0.74 1.8 2.6 5.5 12.4 85 345 5.5 12.4 20
IL = Max.
Ron A
Within 1 s
Maximum 1 1.4 2.5 4 8 16 200 500 8 16 30
on time
IF = 5 mA
Typical 0.3 0.37 0.9 1.4 2.7 6.2 60 345 2.7 6.2 15
IL = Max.
On resistance Ron B
Within 1 s
Maximum 0.5 0.7 1.25 2 4 8 100 500 4 8 20
on time
IF = 5 mA
Typical 0.15 0.18 0.45 0.7 1.4 3.1 30 160 1.4 3.1 7.5
IL = Max.
Ron C
Within 1 s
Maximum 0.25 0.35 0.63 1 2 4 50 250 2 4 10
on time
Off state leakage IF = 0 mA
Maximum ILeak1 A 10 A1 A
current VL = Max.
Typical 1.7 ms 1.4 ms 0.9 ms 1.5 ms 0.8 ms 0.6 ms 0.35 ms 2.4 ms 1.8 ms 1.2 ms
IF = 5 mA
Turn on time* Ton
IL = Max.
Maximum 3 ms 2 ms 3 ms 2 ms 1 ms 4 ms 3ms
Typical 0.07 ms 0.09 ms 0.1 ms 0.06 ms 0.05 ms 0.04 ms 0.06 ms 0.05 ms 0.06 ms
IF = 5 mA
Turn off time* Toff
IL = Max.
Maximum 0.2 ms
Typical 1.3 pF
f = 1 MHz
I/O capacitance Ciso
VB = 0 V
Maximum 3 pF
Initial I/O isolation
Minimum Riso 1,000 M 500 V DC
resistance
*Turn on/Turn off time
Input
90%
Output 10%
Ton Toff
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
Item Symbol Recommended value Unit
Standard type: 5
Input LED current IF mA
Reinforced insulation type: 5 to 10
For Dimensions.
For Schematic and Wiring Diagrams.
For Cautions for Use.
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
For more information.
Continual DC bias (for AQV258, AQV259)
In cases in which a continual DC bias is applied between the input and output, the output-side MOS-FET may deteriorate
due to the voltage. Therefore, please verify operation of the actual design before using. An example of a circuit that might
undergo MOS-FET deterioration due to voltage is given below.
ASCTB143E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
Transfer characteristics Output Input