TESTING VDE GU SOP Form A & B (AQW61S) AQW610S (AQW612S) Both NO and NC contacts incorporated in a small GU SOP Form A & B SOP8-pin package (AQW61S) FEATURES TYPICAL APPLICATIONS 4.4 1. Normally open and normally closed Power supply 9.37 .173 .369 2.1 contacts in a SOP package Measuring equipment .083 The device comes in a miniature SOP Security equipment measuring (W) 4.4 (L) 9.37 (H) 2.1 Telephone equipment mm (W) .173 (L) .369 (H) .083 inch Computer input machines mm inch approx. 38% of the volume and 66% of Industrial robots the footprint size of DIP type. High-speed inspection machines 1 8 N.C. 2. 60V type couples high capacity 2 7 (0.45A) with low on-resistance (typ. 3 6 1 ) (AQW612S). 3. Applicable for 1 Form A 1 Form B 4 5 N.O. use as well as two independent 1 Form A and 1 Form B use 4. Controls low-level analog signals PhotoMOS feature extremely low closed- RoHS compliant circuit offset voltage to enable control of low-level analog signals without distortion 5. Low-level off-state leakage current of max. 1 A TYPES Output rating* Part No. Packing quantity Tape and reel packing style Package Load Load Tube packing style Tube Tape and reel Picked from the Picked from the voltage current 1/2/3/4-pin side 5/6/7/8-pin side 1 tube contains: 60V 450mA AQW612S AQW612SX AQW612SZ AC/DC 50 pcs. SOP8-pin 1,000 pcs. dual use 1 batch contains: 350V 100mA AQW610S AQW610SX AQW610SZ 1,000 pcs. * Indicate the peak AC and DC values. Note: The packing style indicator X or Z are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Item Symbol AQW612S AQW610S Remarks LED forward current IF 50 mA LED reverse voltage VR 5 V Input Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1% Power dissipation Pin 75 mW Load voltage (peak AC) VL 60 V 350 V Peak AC, DC Continuous load current IL 0.45 A (0.55 A) 0.1 A (0.13 A) ( ): in case of using only 1a or 1b, 1 channel Output Peak load current Ipeak 1.5 A 0.3 A 100 ms (1 shot), VL = DC Power dissipation Pout 600 mW Total power dissipation PT 650 mW I/O isolation voltage Viso 1,500 V AC Operating Topr 40C to +85C 40F to +185F Non-condensing at low temperatures Temperature limits Storage Tstg 40C to +100C 40F to +212F ASCTB137E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/eGU SOP Form A & B (AQW61S) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol AQW612S AQW610S Condition Typical 0.9 mA LED operate current IFon IL = Max. Maximum 3 mA Minimum 0.4 mA Input LED reverse current IFoff IL = Max. Typical 0.8 mA Typical 1.25 V (1.14 V at IF = 5 mA) LED dropout voltage VF IF = 50 mA Maximum 1.5 V IF = 5 mA (N.O.) Typical 1 18 IF= 0 mA (N.C.) On resistance Ron IL = Max. Maximum 2.5 25 Within 1 s on time Output IF = 0 mA (N.O.) Off state leakage current Maximum ILeak 1 A IF= 5 mA (N.C.) VL = Max. Typical 0.65 ms (N.O.), 0.9 ms (N.C.) 0.28 ms (N.O.), 0.52 ms (N.C.) Ton (N.O.) IF = 0 mA 5 mA Operate time* Toff (N.C.) IL = Max. Maximum 3.0 ms 1.0 ms Typical 0.08 ms (N.O.), 0.2 ms (N.C.) 0.04 ms (N.O.), 0.23 ms (N.C.) Toff (N.O.) IF = 5 mA 0 mA Reverse time* Transfer Ton (N.C.) IL = Max. Maximum 1.0 ms 1.0 ms characteristics Typical 0.8 pF f = 1 MHz I/O capacitance Ciso VB = 0 V Maximum 1.5 pF Initial I/O isolation resistance Minimum Riso 1,000 M 500 V DC *Operate/Reverse time 1) N.O. 2) N.C. Input Input 90% Output Output 10% 10% 90% Ton Toff Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Symbol Recommended value Unit Input LED current IF 5mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature 2. On resistance vs. ambient temperature 3. Operate time vs. ambient temperature characteristics characteristics characteristics Allowable ambient temperature: 40C to +85C Measured portion: between terminals 5 and 6, LED current: 5 mA 40F to +185F 7 and 8 LED current: 5 mA Load voltage: Max. (DC) Load voltage: Max. (DC) Continuous load current: Max. (DC) Continuous load current: Max. (DC) 50 2.0 600 AQW612S (Using only 1 channel) Between terminals 5 and 6(N.O.) Between terminals 5 and 6(N.O.) Between terminals 7 and 8(N.C.) Between terminals 7 and 8(N.C.) AQW612S 500 40 1.6 (Using 2 channels) 400 30 1.2 AQW612S 300 AQW610S 20 0.8 200 AQW610S (Using only 1 channel) 10 AQW610S 0.4 100 (Using 2 channels) AQW612S AQW610S 0 0 0 -40 -20 020 40 60 80 85 -40 -20 020 40 60 80 85 100 -40 -20 020 40 60 80 85 Ambient temperature, C Ambient temperature, C Ambient temperature, C ASCTB137E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e Load current, mA On resistance, Operate time, ms