HE Form A & B (AQW654)
Both 1 Form A and 1 Form B
contacts incorporated
HE Form A & B
in a compact DIP8-pin
with low on-resistance (AQW654)
FEATURES TYPICAL APPLICATIONS
6.4
1. Applicable for 1 Form A 1 Form B High-speed inspection machines
9.78
.252
.385
use as well as two independent Data communication equipment
3.9
.154
1 Form A and 1 Form B use Telephone equipment
2. Controls low-level analog signals Sensing equipment
6.4
9.78
.252
.385
PhotoMOS feature extremely low closed-
3.6
.142
circuit offset voltage to enable control of
Height includes
low-level analog signals without
standoff
distortion.
mm inch
3. High sensitivity and low on-
resistance
Can control max. 0.16 A load current with
1 8
N.C.
5 mA input current. Low on-resistance of
2 7
max. 11 .
3 6
4. Low-level off state leakage current
4 5 of max. 1 A
N.O.
RoHS compliant
TYPES
Part No.
Output rating* Packing quantity
Through hole
Surface-mount terminal
terminal
Package
Tape and reel packing style
Load Load
Tube packing style Tube Tape and reel
Picked from the Picked from the
voltage current
1/2/3/4-pin side 5/6/7/8-pin side
1 tube contains:
AC/DC 50 pcs.
400 V 120 mA DIP8-pin AQW654 AQW654A AQW654AX AQW654AZ 1,000 pcs
dual use 1 batch contains:
500 pcs.
*Indicate the peak AC and DC values.
Note: The surface mount terminal indicator A and the packing style indicator X or Z are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25C 77F)
Item Symbol AQW654(A) Remarks
LED forward current IF 50 mA
LED reverse voltage VR 5 V
Input
Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1%
Power dissipation Pin 75 mW
Load voltage (peak AC) VL 400 V
Peak AC, DC
Continuous load current IL 0.12A (0.16 A)
( ): in case of using only 1 channel)
Output
Peak load current Ipeak 0.36 A A connection: 100 ms (1 shot), VL = DC
Power dissipation Pout 800 mW
Total power dissipation PT 850 mW
I/O isolation voltage Viso 1,500 V AC Between input and output/between contact sets
Operating Topr 40C to +85C 40F to +185F Non-condensing at low temperatures
Temperature limits
Storage Tstg 40C to +100C 40F to +212F
ASCTB60E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/eHE Form A & B (AQW654)
2. Electrical characteristics (Ambient temperature: 25C 77F)
Item Symbol AQW654(A) Remarks
Typical 0.9 mA
IFon (N.O.)
LED operate current IL = Max.
IFoff (N.C.)
Maximum 3 mA
Minimum 0.4 mA
IFoff (N.O.)
Input LED reverse current IL = Max.
IFon (N.C.)
Typical 0.8 mA
Typical 1.25 V (1.14 V at IF = 5 mA)
LED dropout voltage VF IF = 50 mA
Maximum 1.5 V
IF = 5 mA (N.O.) IF = 0 mA (N.C.)
Typical 11
On resistance Ron IL = Max.
Maximum 16
Within 1 s on time
Output
IF = 0 mA (N.O.)
Off state leakage current Maximum ILeak 1 A IF = 5 mA (N.C.)
VL = Max.
Typical 0.8 ms (N.O.) 1.2 ms (N.C.)
Ton (N.O.) IF = 0 mA 5 mA
Operate time*
Toff (N.C.) IL = Max.
Maximum 2 ms
Typical 0.04 ms (N.O.) 0.36 ms (N.C.)
Toff (N.O.) IF = 5 mA 0 mA
Reverse time*
Transfer
Ton (N.C.) IL = Max.
Maximum 1 ms
characteristics
Typical 0.8 pF
f = 1 MHz
I/O capacitance Ciso
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso 1,000 M 500 V DC
*Operate/Reverse time
1) N.O. 2) N.C.
Input
Input
90%
Output
Output 10%
10%
90%
Ton Toff
Toff Ton
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
Item Symbol Recommended value Unit
Input LED current IF 5mA
For Dimensions.
For Schematic and Wiring Diagrams.
For Cautions for Use.
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
For more information.
REFERENCE DATA
1. Load current vs. ambient temperature 2. On resistance vs. ambient temperature 3. Operate time vs. ambient temperature
characteristics characteristics characteristics
Allowable ambient temperature: 40C to +85C Measured portion: between terminals 5 and 6, LED current: 5 mA; Load voltage: 400 V (DC);
40F to +185F 7 and 8; LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC)
When using 2 channels Continuous load current: 120 mA (DC)
250 4
20
Across terminals 5 and 6 (N.O.)
Across terminals 7 and 8 (N.C.)
18
200
16
3
14
150 12
10 2
100 8
6
1
50 4
Across terminals 5 and 6 (N.O.)
2
Across terminals 7 and 8 (N.C.)
0
0 0
40 20 020 40 60 8085 100 40 20 0 20 40 60 8085 40 20 0 20 40 60 8085
Ambient temperature, C
Ambient temperature, C Ambient temperature, C
ASCTB60E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
Load current, mA
On resistance,
Operate (OFF) time, ms