GU SOP 1 Form A High Capacity (AQY212GS, AQY212G2S)
Miniature SOP4-pin type
GU SOP 1 Form A High Capacity
with high capacity
up to 1.25A
(AQY212GS, AQY212G2S)
AQY212GS,
AQY212G2S
4.3 4.4
FEATURES TYPICAL APPLICATIONS
.169 .173
2.1
1. Greatly increased load current in Measuring instruments
.083
miniature SOP4-pin package (1.25A Security and disaster-preventing
high capacity type added). system: use in I/O for alarm and security
CAD Data
2. Greatly improved specifications devices, etc.
mm inch
allow you to use this in place of
mercury and mechanical relays.
1 4
2 3
TYPES
Output rating* Part No. Packing quantity
Tape and reel packing style
Package
Load Load
Tube packing style Tube Tape and reel
Picked from the Picked from the
voltage current
1/2-pin side 3/4-pin side
1 tube contains:
1.0A AQY212GS AQY212GSX AQY212GSZ
AC/DC 100 pcs.
60V SOP4-pin 1,000 pcs.
dual use 1 batch contains:
1.25A AQY212G2S AQY212G2SX AQY212G2SZ
2,000 pcs.
* Indicate the peak AC and DC values.
Note: 1. For space reasons, the three initial letters of the part number AQY, the surface mount terminal shape indicator S and the packing style
indicator X or Z are not marked on the relay. (Ex. the label for product number AQY212G2SX is 212G2.)
2. Types with a built-in resistor.
RATING
1. Absolute maximum ratings (Ambient temperature: 25C 77 F)
Item Symbol AQY212GS AQY212G2S Remarks
LED forward current IF 50 mA
LED reverse voltage VR 5 V
Input
Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1%
Power dissipation Pin 75 mW
Load voltage (peak AC) VL 60 V
Continuous load current IL 1.0 A 1.25 A Peak AC, DC
Output
Peak load current Ipeak 3 A 100ms (1 shot), VL = DC
Power dissipation Pout 300 mW
Total power dissipation PT 350 mW
I/O isolation voltage Viso 1,500 V AC
Operating Topr 40 C to +85 C 40F to +185F Non-condensing at low temperatures
Temperature limits
Storage Tstg 40C to +100 C 40 F to +212F
ds_x615_en_aqy212gs: 010611D 1GU SOP 1 Form A High Capacity (AQY212GS, AQY212G2S)
2. Electrical characteristics (Ambient temperature: 25 C 77 F)
Item Symbol AQY212GS AQY212G2S Condition
Typical 1.1 mA
LED operate current IFon IL = 100mA
Maximum 3 mA
Minimum 0.3 mA
Input LED turn off current IFoff IL = 100mA
Typical 1.0 mA
Typical 1.32 V (1.14 V at IF = 5 mA)
LED dropout voltage VF IF = 50 mA
Maximum 1.5 V
IF = 5 mA
Typical 0.34 0.2
On resistance Ron IL = Max.
Maximum 0.7 0.5
Within 1 s on time
Output
IF = 0 mA
Off state leakage current Maximum ILeak 1 A
VL = Max.
Typical 1.3 ms IF = 5 mA
Turn on time* Ton IL = 100 mA
Maximum 5.0 ms
VL = 10 V
Typical 0.1 ms IF = 5 mA
Turn off time* Toff IL = 100 mA
Maximum 0.5 ms
VL = 10 V
Transfer
Typical 0.8 pF
characteristics f = 1 MHz
I/O capacitance Ciso
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso 1,000 M 500 V DC
IF = 5 mA
Max. switching frequency Maximum 5 times/s duty = 50%
VL IL = 75 VA
*Turn on/Turn off time
Input
90%
Output 10%
Ton Toff
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper relay operation and resetting.
Item Symbol Recommended value Unit
Input LED current IF 5 to 10 mA
Dimensions
Schematic and Wiring Diagrams
Cautions for Use
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Electric
Works technical representative.
Please refer to our information on PhotoMOS Relays for Automotive Applications.
2 ds_x615_en_aqy212gs: 010611D