(AQY410S, 414S) (AQY412S)
Normally closed
SOP4-pin type
GU SOP 1 Form B
of 60V/350V/400V
load voltage (AQY41S)
FEATURES
4.3 4.4
1. Small SOP4-pin package 3. Controls low-level analog signals
.169
.173
2.1 The device comes in a super-miniature PhotoMOS feature extremely low closed-
.083
SO package 4-pin type measuring circuit offset voltage to enable control of
mm inch
(W) 4.3(L) 4.4(H) 2.1 mm (W) .169(L) low-level analog signals without
.173(H) .083 inch distortion.
1 4 2. Low on-resistance 4. Low-level off-state leakage current
The AQ4 series (normally closed type) of max. 1 A
has a low on-resistance.
This has been achieved thanks to the
2 3
built-in MOSFET processed by our
TYPICAL APPLICATIONS
proprietary method, DSD (Double-
diffused and Selective Doping) method. Power supply
Measuring instruments
Cross section of the normally-closed type of
RoHS compliant
Security equipment
power MOS
Telephone equipment
Passivation membrane
Intermediate
Source electrode Gate electrode
Sensing equipment
insulating
membrane
Gate
oxidation
N+ N+ N+ N+
P+ P+
membrane
N
Drain
electrode
N+
TYPES
Output rating* Part No. Packing quantity
Tape and reel packing style
Package
Load Load
Tube packing style Tube Tape and reel
Picked from the Picked from the
voltage current
1/2-pin side 3/4-pin side
60V 500mA AQY412S AQY412SX AQY412SZ 1 tube contains:
AC/DC 100 pcs.
350V 120mA SOP4-pin AQY410S AQY410SX AQY410SZ 1,000 pcs.
dual use 1 batch contains:
400V 100mA AQY414S AQY414SX AQY414SZ
2,000 pcs.
* Indicate the peak AC and DC values.
Note: For space reasons, the three initial letters of the part number AQY, the surface mount terminal shape indicator S and the packing style indicator X or Z are not
marked on the device. (Ex. the label for product number AQY412SX is 412)
RATING
1. Absolute maximum ratings (Ambient temperature: 25C 77F)
Item Symbol AQY412S AQY410S AQY414S Remarks
LED forward current IF 50 mA
LED reverse voltage VR 5 V
Input
Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1%
Power dissipation Pin 75 mW
Load voltage (peak AC) VL 60 V 350 V 400 V
Continuous load current IL 0.5 A 0.12 A 0.1 A Peak AC, DC
Output
Peak load current Ipeak 1.5 A 0.3 A 0.24 A 100ms (1 shot), VL = DC
Power dissipation Pout 300 mW
Total power dissipation PT 350 mW
I/O isolation voltage Viso 1,500 Vrms
Operating Topr 40 to +85C 40 to +185F (Non-icing at low temperatures)
Ambient
temperature
Storage Tstg 40 to +100C 40 to +212F
ASCTB140E 201703-T
1GU SOP 1 Form B (AQY41S)
2. Electrical characteristics (Ambient temperature: 25C 77F)
Item Symbol AQY412S AQY410S AQY414S Condition
Typical 0.9 mA
LED operate (OFF) current IFoff IL = Max.
Maximum 3 mA
Minimum 0.4 mA
Input LED reverse (ON) current IFon IL = Max.
Typical 0.85 mA
Typical 1.25 V (1.14 V at IF = 5 mA)
LED dropout voltage VF IF = 50 mA
Maximum 1.5 V
IF = 0 mA
Typical 1 18 26
On resistance Ron IL = Max.
Maximum 2.5 25 35
Within 1 s
Output
IF = 5 mA
Off state leakage current Maximum ILeak 1 A
VL = Max.
Typical 0.9 ms 0.52 ms 0.47 ms
IF = 0 mA 5 mA
Operate (OFF) time* Toff
IL = Max.
Maximum 3 ms 1 ms
Typical 0.21 ms 0.23 ms 0.28 ms
IF = 5 mA 0 mA
Reverse (ON) time* Ton
Transfer
IL = Max.
Maximum 1 ms
characteristics
Typical 0.8 pF
f = 1 MHz
I/O capacitance Ciso
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso 1,000 M 500 V DC
*Operate/Reverse time
Input
Output
10%
90%
Toff Ton
3. Recommended operating conditions (Ambient temperature: 25C 77F)
Please use under recommended operating conditions to obtain expected characteristics.
Item Symbol Min. Max. Unit
LED current IF 530 mA
Load voltage (Peak AC) VL 48 V
AQY412S
Continuous load current IL 0.5 A
Load voltage (Peak AC) VL 280 V
AQY410S
Continuous load current IL 0.12 A
Load voltage (Peak AC) VL 320 V
AQY414S
Continuous load current IL 0.1 A
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
REFERENCE DATA
1. Load current vs. ambient temperature 2. On resistance vs. ambient temperature 3. Operate (OFF) time vs. ambient temperature
characteristics characteristics characteristics
Allowable ambient temperature: Measured portion: between terminals 3 and 4; LED current: 5 mA; Load voltage: Max.(DC);
40 to +85C LED current: 0 mA; Continuous load current: Max.(DC)
40 to +185F Continuous load current: Max.(DC)
30
700 2
600
25
AQY414S
AQY412S
1.5
500
20
AQY412S
AQY410S
400
1
15
AQY414S
300
AQY410S
10
200
0.5
AQY410S
5
100
AQY414S
AQY412S
0 0
0
-40 -20 0 20 40 60 80 85 100100 -40 -20 020 40 60 8085 100 -40 -20 0 20 40 60 80 85100
Ambient temperature, C Ambient temperature, C
Ambient temperature, C
ASCTB140E 201703-T
2
Load current, mA
On resistance,
Operate (OFF) time, ms