RX (ARX)
3 GHz SMALL
RX RELAYS (ARX)
MICROWAVE RELAY
FEATURES
1. Excellent high frequency 2. Small size
characteristics (~2.5GHz, Impedance Size: 20.5(L) 12.4(W) 9.4(H) mm
50) .807(L) .488(W) .370(H) inch
Frequency to 2.5GHz 3. High sensitivity
V.S.W.R. (Max.) 1.2 Nominal operating power: 200 mW
Insertion loss (dB, Max.) 0.2
4. Infrequent switching type is also
Isolation (dB, Min.) 60
available. Please inquire.
0
TYPICAL APPLICATIONS
COM-NC
0.1
Cellular phone base station
Cellular phone-related measurement
0.2
devices (SP3T/SP4T switches, etc)
COM-NO
Wireless LAN
0.3
Wireless Local Loop
RoHS compliant
0.4
If you wish to use in applications with low
level loads or with high frequency
0.5
switching, please consult us.
300kHz 1.5GHz 2.5GHz3GHz
Frequency
ORDERING INFORMATION
ARX 1
RX relays
Contact arrangement
1: 1 Form C
Operating function
0: Single side stable
1: 1 coil latching
2: 2 coil latching
Coil voltage (DC)
03: 3V, 4H: 4.5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V
(H=0.5)
TYPES
Part No.
Nominal coil
voltage
Single side stable 1 coil latching 2 coil latching
3 V DC ARX1003 ARX1103 ARX1203
4.5V DC ARX104H ARX114H ARX124H
6 V DC ARX1006 ARX1106 ARX1206
9 V DC ARX1009 ARX1109 ARX1209
12 V DC ARX1012 ARX1112 ARX1212
24 V DC ARX1024 ARX1124 ARX1224
Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package
ASCTB74E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
Insertion loss, dBRX (ARX)
RATING
1. Coil data
1) Single side stable
Nominal operating
Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 60C 140F)
[10%] (at 20C 68F)
3 V DC 66.7mA 45
4.5V DC 44.4mA 101
75%V or less of 10%V or more of
6 V DC 33.3mA 180
110%V of nominal
nominal voltage nominal voltage 200mW
voltage
9 V DC 22.2mA 405
(Initial) (Initial)
12 V DC 16.7mA 720
24 V DC 8.3mA 2,880
2) 1 coil latching type
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 60C 140F)
[10%] (at 20C 68F)
3 V DC 66.7mA 45
4.5V DC 44.4mA 101
75%V or less of 75%V or less of
6 V DC 33.3mA 180
110%V of nominal
nominal voltage nominal voltage 200mW
voltage
9 V DC 22.2mA 405
(Initial) (Initial)
12 V DC 16.7mA 720
24 V DC 8.3mA 2,880
3) 2 coil latching type
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 60C 140F)
[10%] (at 20C 68F)
3 V DC 133.3mA 22.5
4.5V DC 88.9mA 50.6
75%V or less of 75%V or less of
6 V DC 66.7mA 90
110%V of nominal
nominal voltage nominal voltage
400mW
voltage
9 V DC 44.4mA 202.5
(Initial) (Initial)
12 V DC 33.3mA 360
24 V DC 16.7mA 1,440
2. Specications
Characteristics Item Specications
Arrangement 1 Form C
Contact Contact material Stationary: Gold plating, Movable: Gold clad
Initial contact resistance, max. Max. 100m (By v oltage drop 10V AC 10mA)
Contact rating 10W (2.5GHz, Impedance 50, V.S.W.R. 1.2) 10mA 24V DC (resistive load)
Contact carrying power Max. 20W (at 2.5GHz, Impedance 50, V.S.W.R. 1.2, Average)
Max. switching voltage 30V DC
Rating Max. switching current 0.5A DC
Single side stable 200mW
Nominal
operating 1 coil latching 200mW
power
2 coil latching 400mW
V.S.W.R. (Return loss) Max. 1.2 (Min. 20.8dB)
High frequency
Insertion loss Max. 0.2dB
characteristics
(Initial) (~2.5GHz,
Isolation Min. 60dB
Impedance 50)
Input power Max. 20W (at 40C, V.S.W.R. 1.2, Average)
Min. 100M (at 500V DC)
Insulation resistance (Initial)
Measurement at same location as Initial breakdown voltage section.
Between open contacts 500 Vrms for 1min. (Detection current: 10mA)
Breakdown
voltage Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA)
(Initial)
Between contact and earth terminal 500 Vrms for 1min. (Detection current: 10mA)
Electrical
Max. 60C (By resistive method, nominal voltage applied to the coil: Contact carrying
characteristics
Temperature rise (at 20C)
power: 20W, at 2.5GHz, Impedance 50, V .S.W.R. 1.2)
Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied
Operate time [Set time] (at 20C)
to the coil, excluding contact bounce time.)
Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied to
Release time [Reset time] (at 20C)
the coil, excluding contact bounce time.) (without diode)
2
Functional Min. 200 m/s {20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10s.)
Shock
2
resistance
Destructive Min. 1,000m/s {100 G} (Half-wave pulse of sine wave: 6ms.)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 3mm (Detection time: 10s.)
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 5mm
6
Mechanical Min. 510 (at 180 cpm)
5
Expected life
Min. 10 (10W 2.5 GHz, Impedance 50, V .S.W.R. 1.2)
Electrical
5
Min. 310 (10mA 24V DC resistive load)
Ambient temperature: 40C to +70C 40F to +158F
Conditions Conditions for operation, transport and storage*
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz
Note: * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
ASCTB74E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e