Conductive Polymer Tantalum Solid Capacitors Surface Mount Type Series : TPU Features Small size, Low pro le (L2.0 W 1.25 H 0.9 mm) Face down terminal type RoHS compliance, Halogen free Specifi cations Size code S09 B09 Category temperature range 55 C to +85 C Rated voltage range 2.5 V.DC to 10 V.DC 6.3 V.DC Category voltage range 2.5 V.DC to 10 V.DC 6.3 V.DC Rated capacitance range 4.7 F to 100 F 150 F Capacitance tolerance 20 % (120 Hz / + 20 C) Leakage current Please see the attached characteristics list Dissipation factor (tan d) Please see the attached characteristics list Surge voltage (V.DC) Rated voltage 1.15 +85 C, 1000 h, rated voltage applied Capacitance change Within 20 % of the initial value Endurance tan d < 1.5 times of the initial limit DC leakage current Within the initial limit +60 C, 90 % to 95 %, 500 h, No-applied voltage Capacitance change Within +40 %, 20 % of the initial value Damp heat (Steady State) tan d < 1.5 times of the initial limit DC leakage current < 3 times of the initial limit Marking Dimensions (not to scale) L S09 Size B09 Size Polarity marking(+) R.Cap. code Polarity R.Cap. code marking(+) R. Voltage code Lot. No. R. Voltage code Lot. No. R. Voltage (V.DC) 2.5 4.0 6.3 10.0 W1 S S Code eg j A S09 Size R. Cap. (F) 4.7 10 22 47 68 100 Unit : mm Code sAJ S W A 1 1 1 Size code L0.1 W0.1 H0.1 S0.1 W10.1 B09 Size S09 2.0 1.25 0.9 0.5 0.9 R. Cap. (F) 150 B09 3.5 2.8 0.9 0.8 2.2 Code E8 1 0.2 : B09 Externals of gure are the reference. Characteristics list Case size (mm) Specifications Standard Floor life Rated Rated Category Category Rated 1 Size Ripple Min. Re ow Re ow 2 4 Series voltage temp. voltage temp. capacitance ESR LC 3 code LW H current tan d Part number Packaging Q ty Temp Temp (V.DC) (C) (V.DC) (C) (F) (m max.) (A) (mAr.m.s.) (pcs) < 260C < 250C 85 2.5 85 47 2.0 1.25 0.9 510 150 0.10 23.5 2R5TPU47MSI 3000 2.5 85 2.5 85 100 2.0 1.25 0.9 510 150 0.10 50.0 ETPU100MSI 3000 4 85 4.0 85 68 2.0 1.25 0.9 510 150 0.10 54.4 4TPU68MSI 3000 S09 85 6.3 85 10 2.0 1.25 0.9 400 250 0.10 6.3 6TPU10MSI 3000 TPU 3 85 6.3 85 22 2.0 1.25 0.9 510 150 0.10 27.7 6TPU22MSI 3000 6.3 85 6.3 85 47 2.0 1.25 0.9 510 150 0.10 59.2 6TPU47MSI 3000 85 6.3 85 150 3.5 2.8 0.9 B09 670 100 0.10 94.5 6TPU150MBI 3000 3 10 85 10.0 85 4.7 2.0 1.25 0.9 S09 360 300 0.10 4.7 10TPU4R7MSI 3000 1 Ripple current (100 kHz/ +45 C ), 2 ESR (100 kHz/+20 C) 3 tan d (120 Hz/+20 C) 4 After 5 minutes Please refer to each page in this catarog for Reflow conditions and Taping specifications. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Jun. 2018 H WGuidelines and precautions regarding the technical information and use of our products described in this online catalog. If you want to use our products described in this online catalog for applications requiring special qualities or reliability, or for applications where the failure or malfunction of the products may directly jeopardize human life or potentially cause personal injury (e.g. aircraft and aerospace equipment, traffic and transportation equipment, combustion equipment, medical equipment, accident prevention, anti-crime equipment, and/or safety equipment), it is necessary to verify whether the specifications of our products fit to such applications. Please ensure that you will ask and check with our inquiry desk as to whether the specifications of our products fit to such applications use before you use our products. The quality and performance of our products as described in this online catalog only apply to our products when used in isolation. Therefore, please ensure you evaluate and verify our products under the specific circumstances in which our products are assembled in your own products and in which our products will actually be used. If you use our products in equipment that requires a high degree of reliability, regardless of the application, it is recommended that you set up protection circuits and redundancy circuits in order to ensure safety of your equipment. The products and product specifications described in this online catalog are subject to change for improvement without prior notice. Therefore, please be sure to request and confirm the latest product specifications which explain the specifications of our products in detail, before you finalize the design of your applications, purchase, or use our products. The technical information in this online catalog provides examples of our products typical operations and application circuits. We do not guarantee the non-infringement of third party s intellectual property rights and we do not grant any license, right, or interest in our intellectual property. If any of our products, product specifications and/or technical information in this online catalog is to be exported or provided to non-residents, the laws and regulations of the exporting country, especially with regard to security and export control, shall be observed. <Regarding the Certificate of Compliance with the EU RoHS Directive/REACH Regulations> The switchover date for compliance with the RoHS Directive/REACH Regulations varies depending on the part number or series of our products. When you use the inventory of our products for which it is unclear whether those products are compliant with the RoHS Directive/REACH Regulation, please selectSales Inquir in the website inquiry form and contact us. We do not take any responsibility for the use of our products outside the scope of the specifications, descriptions, guidelines and precautions described in this online catalog. 01-Oct-19