VDE HE TV-15, 30 AMP (1 Form A) HE RELAYS Power Relay 50 FEATURES 1.969 33 1.299 High contact capacity with superior inrush current characteristics 1 Form A 2 Form A 35.8 Rating 30 A 277 V AC 25 A 277 V AC 1.409 TV rating TV-15 TV-10 Excellent high heat-resistance High dielectric strength: 10,000 V surge Conforming to VDE0806 mm inch (Insulation gap: 8 mm .315 inch) VDE, TV also approved SPECIFICATIONS Contacts Characteristics Type DC coil type AC coil type DC coil type AC coil type Arrangement 1a 2a 1a 2a Maximum operating speed 20 cpm Contact material Silver alloy 1 Initial insulation resistance* Min. 1,000 M at 500 V DC Initial contact resistance, max. Between open contacts 2,000 Vrms for 1 min. 100 m (By voltage drop 6 V DC 1A) Initial Between contacts and 30 A 25 A 30 A 25 A 5,000 Vrms for 1 min. Nominal breakdown coil 277 V 277 V 277 V 277 V 2 switching capacity voltage* Between contact sets AC AC AC AC 4,000 Vrms for 1 min. (2a) Max. switching 8,310 6,925 8,310 6,925 Rating power VA VA VA VA Surge voltage between coil (resistive) Min. 10,000 V 3 and contact* Max. switching voltage 277 V AC, 30 V DC 4 Operate time* Max. switching current 30 A 25 A 30 A 25 A Max. 30 ms (at nominal voltage) 1 Min. switching capacity 100 mA, 5 V DC 4 Release time* Mechanical Max. 10 ms Max. 30 ms 7 6 10 5 10 Expected (at nominal voltage) (at 180 cpm) life (min. 5 Temperature rise, max. Electrical 10 (1a: 30 A 277 V AC, 2a: 25 A 277 V AC) 60 C65 C operations) 5 (resistive load)(at 55C) (at 20 cpm) 210 (1a: 30 A 250 V AC, 2a: 20 A 250 V AC) 5 2 Functional* 98 m/s 10 G Coil (at 20 C 68F) Shock resistance 6 2 Destructive* 980 m/s 100 G DC coil type AC coil type 10 to 55 Hz 7 Nominal operating power 1.92 W See Coil data (next page) Functional* at double amplitude of 1 mm Vibration resistance 1 This value can change due to the switching frequency, environmental conditions, 10 to 55 Hz and desired reliability level, therefore it is recommended to check this with the Destructive at double amplitude of 1.5 mm actual load. Remarks Conditions for opera- Ambient 50 C to +55 C * Specifications will vary with foreign standards certification ratings. tion, transport and stor- temp. 58 F to +131 F 1 8 * Measurement at same location as initial breakdown voltage section age* (Not freezing and Humidity 5 to 85% R.H. 2 * Detection current: 10 mA condensing at low tem- 3 * Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981 Air pressure 86 to 106 kPa perature) 4 * Excluding contact bounce time 5 Approx. 90 g 3.17 oz * Half-wave pulse of sine wave: 11ms detection time: 10s Unit weight 6 * Half-wave pulse of sine wave: 6ms (Plug-in type) 7 * Detection time: 10 s 8 * Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (see catalog). TYPICAL APPLICATIONS ORDERING INFORMATION 1. Home appliances HE 1a N S DC12 V Air conditioners Microwave ovens Contact arrangement Pick-up voltage Terminals Coil voltage TV sets 1a: 1 Form A N: 70% of nominal Nil: Plug-in terminal type DC: 6, 12, 24, 48, Heaters 2a: 2 Form A voltage S: Screw terminal type 110 V Stereo SW: Screw terminal type AC: 12, 24, 48, 2. Office equipment (wide pitch) 120, 240 V Copiers Q: NEMA terminal type Vending machines P: PC board terminal type* Standard packing: Carton: 20 pcs. Case: 100 pcs. * PC board terminal are available only for 1 Form A type of DC coil voltage. UL/CSA, TV approved type is standard. en ds 61120 0000: 310105J 1HE TYPES Contact arrangement Contact arrangement Terminal shape Terminal shape 1 Form A 2 Form A 1 Form A 2 Form A HE1aN-DC6V HE2aN-DC6V HE1aN-AC12V HE2aN-AC12V HE1aN-DC12V HE2aN-DC12V HE1aN-AC24V HE2aN-AC24V Plug-in terminal HE1aN-DC24V HE2aN-DC24V Plug-in terminal HE1aN-AC48V HE2aN-AC48V HE1aN-DC48V HE2aN-DC48V HE1aN-AC120V HE2aN-AC120V HE1aN-DC110V HE2aN-DC110V HE1aN-AC240V HE2aN-AC240V HE1aN-S-DC6V HE2aN-S-DC6V HE1aN-S-AC12V HE2aN-S-AC12V HE1aN-S-DC12V HE2aN-S-DC12V HE1aN-S-AC24V HE2aN-S-AC24V Screw terminal HE1aN-S-DC24V HE2aN-S-DC24V Screw terminal HE1aN-S-AC48V HE2aN-S-AC48V HE1aN-S-DC48V HE2aN-S-DC48V HE1aN-S-AC120V HE2aN-S-AC120V HE1aN-S-DC110V HE2aN-S-DC110V HE1aN-S-AC240V HE2aN-S-AC240V AC type HE1aN-SW-DC6V HE2aN-SW-DC6V HE1aN-SW-AC12V HE2aN-SW-AC12V HE1aN-SW-DC12V HE2aN-SW-DC12V HE1aN-SW-AC24V HE2aN-SW-AC24V DC Screw terminal Screw terminal HE1aN-SW-DC24V HE2aN-SW-DC24V HE1aN-SW-AC48V HE2aN-SW-AC48V type (wide pitch) (wide pitch) HE1aN-SW-DC48V HE2aN-SW-DC48V HE1aN-SW-AC120V HE2aN-SW-AC120V HE1aN-SW-DC110V HE2aN-SW-DC110V HE1aN-SW-AC240V HE2aN-SW-AC240V HE1aN-Q-DC6V HE2aN-Q-DC6V HE1aN-Q-AC12V HE2aN-Q-AC12V HE1aN-Q-DC12V HE2aN-Q-DC12V HE1aN-Q-AC24V HE2aN-Q-AC24V NEMA terminal HE1aN-Q-DC24V HE2aN-Q-DC24V NEMA terminal HE1aN-Q-AC48V HE2aN-Q-AC48V HE1aN-Q-DC48V HE2aN-Q-DC48V HE1aN-Q-AC120V HE2aN-Q-AC120V HE1aN-Q-DC110V HE2aN-Q-DC110V HE1aN-Q-AC240V HE2aN-Q-AC240V HE1aN-P-DC6V HE1aN-P-DC12V PC board HE1aN-P-DC24V terminal HE1aN-P-DC48V HE1aN-P-DC110V COIL DATA at 20C 68 F Max. allowable Drop-out Nominal coil Nominal Pick-up voltage, Coil resistance, voltage Nominal voltage voltage, current, operating power, V DC (max.) (10%) (at 50 C 122 F), V DC (min.) mA (10%) W V DC 6 V DC 4.2 0.6 320.9 18.8 1.92 6.6 12 V DC 8.4 1.2 160 75 1.92 13.2 DC coil type 24 V DC 16.8 2.4 80 300 1.92 26.4 48 V DC 33.6 4.8 40 1200 1.92 52.8 110 V DC 77.0 11.0 17.5 6300 1.92 121.0 Max. allowable Drop-out Nominal coil Nominal Pick-up voltage, Coil resistance, voltage Nominal voltage voltage, current, operating power, V AC (max.) (10%) (at 50 C 122 F), V AC (min.) mA (10%) VA V AC 12 V AC 8.4 1.8 138* 75 1.7 13.2 24 V AC 16.8 3.6 74* 300 1.8 26.4 AC coil type 48 V AC 33.6 7.2 39* 1200 1.9 52.8 120 V AC 70.0 18.0 22.1* 5200 2.7 132.0 240 V AC 140.0 36.0 10.8* 20800 2.6 264.0 *Value at 60 Hz 2 en ds 61120 0000: 310105J