HE-V Max. 1,000 V DC, 20 A cut-off possible HE-V RELAYS High capacity power relays FEATURES TYPICAL APPLICATIONS Compact size Photovoltaic power generation (L: 41.0 W: 50.0 H: 39.4 mm systems L: 1.614 W: 1.969 H: 1.551 inch) Battery charge and discharge Maximum 1,000 V DC, 20 A cut-off has systems been achieved (at each 1 Form A contact Inverter control, DC load control, etc. connected in series) Contact connection method RoHS compliant Contact arrangement: 2 Form A 400 DC, 20 A per 1 Form A Contributes to energy saving in devices thanks to reduced coil hold voltage Coil hold voltage can be reduced down to 33% of the nominal coil voltage. This equals to operating power of approximately 210 mW. *Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. Protective construction: Flux-Resistant type ORDERING INFORMATION HEV 2a N P DC Contact arrangement 2a: 2 Form A (Single side stable type) Pick-up voltage N: 70% of nominal voltage Terminals P: PC board terminal type Coil voltage (DC) 6V, 9V, 12V, 15V, 24V TYPES Nominal coil voltage Part No. 6V DC HEV2aN-P-DC6V 9V DC HEV2aN-P-DC9V 12V DC HEV2aN-P-DC12V 15V DC HEV2aN-P-DC15V 24V DC HEV2aN-P-DC24V Standard packing: Carton: 10 pcs. Case: 50 pcs. ASCTB326E 201212-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/HE-V RATING 1. Coil data Pick-up voltage Drop-out voltage Nominal operating Nominal coil Coil resistance Nominal operating Max. applied voltage (at 20C 68F) (at 20C 68F) current voltage 10% (at 20C 68F) power (at 55C 131F) (Initial) (Initial) 10% (at 20C 68F) 6V DC 320mA 18.8 9V DC 213mA 42.2 70%V or less of 5%V or more of 110%V of 12V DC 160mA 75.0 1,920mW nominal voltage nominal voltage nominal voltage 15V DC 128mA 117.0 24V DC 80mA 300.0 2. Specications Characteristics Item Specications Arrangement 2 Form A Contact material AgNi type Contact Max. 100 m (By voltage drop 6 V DC 1 A), Contact resistance (Initial) Max. 3 m (By voltage drop 6 V DC 20 A, Reference value) 20 A 800 VDC (at each 1 Form A contact connected in series), Contact rating (Resistive load) 20 A 400 VDC (at 1 Form A contact only) Max. switching voltage 1,000 V DC Rating Max. switching current 20 A 1 Min. switching capacity (Reference value)* 100 mA 5 V DC Insulation resistance (Initial) Min. 1,000M (at 1,000V DC) Measurement at same location as Breakdown voltage section. Short current (Initial) Max. 300 A 1 ms (Reference value) Between open contacts 2,000 Vrms for 1 min. (Detection current: 10 mA) Breakdown Between contact sets 4,000 Vrms for 1 min. (Detection current: 10 mA) voltage (Initial) Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA) 2 Surge breakdown voltage* Min. 10,000 V (Between contact and coil) (Initial) Electrical characteristics Max. 75C 135F (By resistive method, contact carrying current: 20A, 100%V of nominal coil voltage at 55C 131F.) Coil temperature rise value Max. 45C 113F (By resistive method, contact carrying current: 20A, 60%V of nominal coil voltage at 85C 185F.) 33 to 110%V (Contact carrying current: 20A, at 55C 131F), 3 Coil holding voltage* 33 to 60%V (Contact carrying current: 20A, at 85C 185F) Operate time (at 20C 68F) Max. 30 ms (nominal coil voltage, without bounce) Release time (at 20C 68F) Max. 10 ms (nominal coil voltage) (without diode) 2 Functional Min. 98 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10 s) Shock resistance 2 Destructive Min. 980 m/s (Half-wave pulse of sine wave: 6 ms) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 s) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 1.5 mm 6 Expected life Mechanical life Min. 10 (at 180 cpm) Ambient temperature: Conditions for operation, transport and 40 to +55C 40 to +131F (When coil holding voltage is 33% to 110% of nominal coil voltage) 4 storage* 40 to +85C 40 to +185F (When applied coil hold voltage is 33% to 60% of nominal coil voltage) Conditions Humidity: 5 to 85% R.H. (Not freezing and condensing) Max. operating speed 6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s) Unit weight Approx. 120 g 4.23 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. Coil holding voltage is the coil voltage after 100 ms following application of the nominal coil voltage. *4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. ASCTB326E 201212-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/