VDE JQ High electrical & mechanical JQ RELAYS noise immunity relay 10 20 About Cd-free contacts FEATURES .394 .787 We have introduced cadmium-free type High electrical noise immunity products to reduce environmentally High switching capacity in a compact 15.6 hazardous substances. Please replace .614 package parts that contain cadmium with Cd-free High sensitivity: 200 mW (1a), products. Evaluate them with your actual 400 mW (1c) application before use because the life of High surge voltage: 8,000 V between a relay depends on the contact material contacts and coil and load. UL, CSA, VDE, TV, SEMKO mm inch approved Class B coil insulation type available SPECIFICATIONS Contact Standard type High capacity type Arrangement 1 Form A, 1 Form C Initial contact resistance, max. 100 m (By voltage drop 6 V DC 1 A) Contact material AgSnO2 type 1a 5 A 125 V AC, 2 A 250 V AC, 5 A 30 V DC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC Nominal switching N.O. 5 A 125 V AC, 2 A 250 V AC, 3 A 30 V AC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC capacity 1c N.C. 2 A 125 V AC, 1 A 250 V AC, 1 A 30 V DC 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC 1a 625 VA, 150 W 1,250 VA, 150 W Rating Max. switching power N.O. 625 VA, 90 W 1,250 V AC, 150 W (resistive) 1c N.C. 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A 1 Min. switching capacity 100 mA, 5 V DC 7 Expected mechanical life (at 180 cpm)(min. operations) 10 Expected electrical life (min. operations) Type Switching capacity No. of operations 4 5 A 125 V AC 5 10 5 3 A 125 V AC 2 10 1a 5 2 A 250 V AC 2 10 5 5 A 30 V DC 10 4 5 A 125 V AC 5 10 Standard type 5 N.O. 2 A 250 V AC 2 10 5 3 A 30 V DC 10 1c 5 2 A 125 V AC 2 10 5 N.C. 1 A 250 V AC 2 10 5 1 A 30 V DC 10 4 10 A 125 V AC 5 10 4 1a 5 A 250 V AC 5 10 5 5 A 30 V DC 10 4 10 A 125 V AC 5 10 4 High capacity type N.O. 5 A 250 V AC 5 10 5 5 A 30 V DC 10 1c 5 3 A 125 V AC 2 10 5 N.C. 2 A 250 V AC 2 10 5 1 A 30 V DC 10 Coil (at 20C 68 F) Nominal operating power 1a: 200 mW 1c: 400 mW 1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. ds 61B03 en jq: 100811D 1JQ Characteristics Max. operating speed 20 cpm 1 Initial insulation resistance* Min. 1,000 M at 500 V DC 1a: 1,000 Vrms for 1 min. Between open contacts 2 1c: 750 Vrms for 1 min. Initial breakdown voltage* Between contacts and coil 4,000 Vrms for 1 min. 3 Surge voltage between contact and coil* 8,000 V 4 Operate time* (at nominal voltage) Max. 20 ms 4 Release time* (at nominal voltage)(without diode) Max. 10 ms 5 Temperature rise* Max. 45 C 6 2 Functional* Min. 294 m/s 30 G Shock resistance 7 2 Destructive* Min. 980 m/s 100 G 8 2 Functional* 98 m/s 10 G , 10 to 55 Hz at double amplitude of 1.6 mm Vibration resistance 2 Destructive 117.6 m/s 12 G , 10 to 55 Hz at double amplitude of 2.0 mm 10 9 Ambient temp.* 40C to +85C 40 F to +185F Conditions for operation, transport and storage* (Not freezing and condensing at low temperature) Humidity 5 to 85% R.H. Unit weight Approx. 7 g .25 oz Remarks * Specifications will vary with foreign standards certification ratings. 1 * Measurement at same location as Initial breakdown voltage section 2 * Detection current: 10 mA 3 * Wave is standard shock voltage of 1.2 50s according to JEC-212-1981 4 * Excluding contact bounce time 5 * Measured conditions Standard type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70 C 158F High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70 C 158F 6 * Half-wave pulse of sine wave: 11ms detection time: 10s 7 * Half-wave pulse of sine wave: 6ms 8 * Detection time: 10 s 9 * Refer to 6. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information. 10 * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range. TYPICAL APPLICATIONS Air conditioners Refrigerators Microwave ovens Heaters ORDERING INFORMATION Ex. JQ 1a P B 12 V F Contact Contact capacity Coil insulation class Coil voltage (DC) Contact material arrangement 1a: 1 Form A Nil: Standard Nil: Class E coil insulation 5, 6, 9, 12, 18, 24, 48* V F: AgSnO2 type 1: 1 Form C P: High capacity B: Class B coil insulation UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type 2 ds 61B03 en jq: 100811D