DIN 48 SIZE LC4H-W LCD ELECTRONIC COUNTER Counters UL File No.: E122222 C-UL File No.: E122222 Features 1. Two-stage presetting (upper and 5. Conforms to IP66s Weather lower limits) Resistant Standards SET2 The water-proof panel keeps out water and dirt for reliable operation even in SET1 48 poor environments. 1.890 6. Screw terminal and Pin Type are Both Standard Options Output 1 The two terminal types are standard Output 2 64.5 options to support either front panel 48 2.539 1.890 2. Bright and Easy-to-Read Display installation or embedded installation. A brand new bright 2-color backlight LCD 7. Changeable Panel Cover mm inch display. The easy-to-read screen in any Also offers a black panel cover to meet location makes checking and setting pro- your design considerations. cedures a cinch. 8. Compliant with UL, c-UL and CE. 3. Simple Operation 9. Low Price Seesaw buttons make operating the unit All this at an affordable price to provide even easier than before. you with unmatched cost performance. 11-pin type Screw terminal type 4. Short Body of only 64.5 mm 2.539 inch (screw type) or 70.1 mm 2.760 inch (pin type) RoHS Directive compatibility information With a short body, it easily installs in LC4H-W Specifications Ralay output type Transistor output type Item AC type DC type AC type DC type 100 to 240 V AC 100 to 240 V AC Rated operating voltage 12 to 24 V DC 12 to 24 V DC 24 V AC 24 V AC Rated frequency 50/60 Hz common 50/60 Hz common Rated power consumption Max. 10 V A Max. 3 W Max. 10 V A Max. 3 W Rated control capacity 3 A, 250 V AC (resistive load) 100 mA, 30 V DC Input mode Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) (5 modes selectable by DIP switch) Counting speed 30 Hz(cps)/5 KHz(cps) (selectable by DIP switch) Counting input (Input 1, 2) Min. input signal width: 16.7 ms at 30 Hz(cps)/0.1 ms at 5 KHz(cps) ON time: OFF time = 1:1 Reset input Min. input signal width: 1 ms, 20 ms (selected by DIP switch) Rating Contact or Open collector input/Input impedance: 1 k or less, Input residual voltage: 2 V or less, Input signal Open impedance: 100 k or more, Max. energized voltage: 40 V DC Output 1. HOLD-B, C, D SHOT-A (4 modes) Output mode Output 2. HOLD-A, B, C SHOT-A, B, C, D (8 modes) (selectable by DIP switch) One shot output time Approx. 1 s Indication 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) Digit 99999 to 999999 (5 digits to 6 digits) (0 to 999999 for setting) 5 Memory EEP-ROM (Overwriting times: 10 ope. or more) Contact arrangement 1 Form A + 1 Form A 1 Form A + 1 Form A (Open collector) Contact Contact resistance (Intial value) 100 m (at 1 A 6 V DC) Contact material Ag alloy/Au flush 7 Mechanical (contact) Min. 2 10 ope. Life 5 7 Electrical (contact) Min. 10 ope. (At rated control voltage) Min. 10 ope. (At rated control voltage) Allowable operating 85 to 110 % of rated operating voltage voltage range Between live and dead metal parts: 2,000 Vrms for 1 min (pin type) Break down voltage Between live and dead metal parts: 2,000 Vrms for 1 min Between input and output: 2,000 Vrms for 1 min (Initial value) Between input and output: 2,000 V AC for 1 min Between open contacts: 1,000 Vrms for 1 min Electrical Insulation resistance Between live and dead metal parts: Min. 100 M (pin type) Between live and dead metal parts: Min. 100 M (pin type) (At 500 V DC) (Initial Between input and output: Min. 100 M Between input and output: Min. 100 M value) Between open contact: Min. 100 M Max. 65C Temperature rise (under the flow of nominal operating current at nominal voltage) Functional 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm (10 min on 3 axes) Vibration resistance Destructive 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm (1 h on 3 axes) Mechanical 2 Functional Min. 98 m/s (4 times on 3 axes) Shock resistance 2 Destructive Min. 294 m/s (5 times on 3 axes) Ambient temperature 10C to 55C +14F to +131F Ambient humidity Max. 85 % RH (non-condensing) Operating conditions Air pressure 860 to 1,060 h Pa Ripple rate 20 % or less 20 % or less Connection 11-pin/screw terminal Protective construction IP66 (front panel with a rubber gasket) Applicable standard Safety standard EN61812-1 Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength EN55011 Group1 ClassA Noise terminal voltage EN55011 Group1 ClassA (EMS)EN61000-6-2 Static discharge immunity EN61000-4-2 4 kV contact 8 kV air RF electromagnetic field immunity EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EMC EFT/B immunity EN61000-4-4 2 kV (power supply line) 1 kV (signal line) Surge immunity EN61000-4-5 1 kV (power line) Conductivity noise immunity EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) Power frequency magnetic field immunity EN61000-4-8 30 A/m (50 Hz) Voltage dip/Instantaneous stop/Voltage fluctuation immunity EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95% (rated voltage) All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.