LK-Q TV-5/TV-8 rated. 1a 5A/8A silent type LK-Q RELAYS power relays FEATURES 1. High sensitivity 5. Conforms to the various safety A nominal operating power of 250mW standards and high sensitivity make it ideal for UL/C-UL, TV, and SEMKO approved energy saving (LK relay is 530mW). 2. Silent TYPICAL APPLICATIONS Approx. 10 dB less sound pressure than previous LK series relay Flat-panel TVs 3. High inrush current capability Audio visual equipment Switching capability TV-5 type: inrush 100A, steady: 5A TV-8 type: inrush 118A, steady: 8A 4. High insulation resistance 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC60065) 2) Surge withstand voltage between contact and coil: 10,000 V ORDERING INFORMATION LKQ 1a F LK-Q relay Contact arrangement 1a: 1 Form A Protective construction F: Flux-resistant type Nominal coil voltage (DC) 5V, 9V, 12V, 24V TV standard TV5: TV-5 TV8: TV-8 Note: Certified by UL/C-UL, TV and SEMKO TYPES Part No. Contact arrangement Nominal coil voltage TV-5 type TV-8 type 5V DC LKQ1aF-5V-TV5 LKQ1aF-5V-TV8 9V DC LKQ1aF-9V-TV5 LKQ1aF-9V-TV8 1 Form A 12V DC LKQ1aF-12V-TV5 LKQ1aF-12V-TV8 24V DC LKQ1aF-24V-TV5 LKQ1aF-24V-TV8 Standard packing Carton: 100 pcs. Case: 500 pcs. RATING 1. Coil data Nominal operating Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage current voltage (at 20 C 68F) (at 20 C 68F) 10% (at 20C 68F) power (at 20 C 68F) 10% (at 20C 68 F) 5V DC 50mA 100 6.5V DC 80%V or less of 10%V or more of 9V DC 27.8mA 324 11.7V DC nominal voltage nominal voltage 250mW 12V DC 20.8mA 576 15.6V DC (Initial) (Initial) 24V DC 10.4mA 2,304 31.2V DC ds 61B13 en lkq: 290212J 1LK-Q 2. Specifications Specifications Characteristics Item TV-5 type TV-8 type Arrangement 1 Form A Contact Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A) Contact material AgSnO2 type Nominal switching capacity (resistive load) 5A 277V AC 8A 277V AC Max. switching power (resistive load) 1,385VA 2,216VA Rating Max. switching voltage 277V AC Max. switching current 5A (AC) 8A (AC) 1 Min. switching capacity (reference value)* 100mA, 5V DC Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA) Breakdown voltage (Initial) Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 35 C 95F (with nominal coil voltage and Max. 35 C 95F (with nominal coil voltage and Temperature rise (coil) at 5A contact carrying current, at 70 C 158 F) at 8A contact carrying current, at 70C 158 F) Electrical 2 Surge breakdown voltage* characteristics 10,000 V (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20 C 68F) Max. 15 ms (excluding contact bounce time.) (Initial) Release time (at nominal voltage) (at 20C 68 F) Max. 5 ms (excluding contact bounce time) (Without diode) (Initial) 2 Functional 200 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive 1,000 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 1.5 mm 6 Mechanical (at 180 times/min.) Min. 10 Expected life 5 4 Min. 10 (ON: 1.5s, OFF: 1.5s, at nominal Min. 510 (ON: 1.5s, OFF: 1.5s, at nominal Electrical switching capacity) switching capacity) Ambient temperature: 40 C to +70C 40 F to +158F, 3 Conditions for operation, transport and storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature), Conditions Air pressure: 86 to 106kPa Max. operating speed 20 times/min. (at nominal switching capacity) Unit weight Approx. 12 g .42 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information. REFERENCE DATA 1. Max. switching power (AC resistive load) 2-(1). Coil temperature rise (TV-5 type) 2-(2). Coil temperature rise (TV-8 type) Sample: LKQ1aF-12V-TV5, 6 pcs. Sample: LKQ1aF-12V-TV8, 6 pcs. Point measured: coil inside Point measured: coil inside Contact current: 0A, 5A Contact current: 0A, 8A 30 30 100 20C 8A 20C 5A 20C 0A 20C 0A 25 25 70C 8A 70C 5A TV-8 type 70C 0A 70C 0A 20 10 20 8 5 15 15 TV-5 type 10 1 10 5 5 0 0 0 80 100 120 0 10 100 0 80 100 120 Coil applied voltage, %V Coil applied voltage, %V Contact voltage, V 2 ds 61B13 en lkq: 290212J Contact current, A Temperature rise, C Temperature rise, C