PM4H-A/S/M
PM4H-A
DIN48 SIZE
MULTI-RANGE
PM4H-S
ANALOG TIMER
PM4H-M
UL File No.: E122222
CSA File No.: LR39291
Features
100-240V AC free-voltage input, 48-125V DC type available
48
1.890
Short body 62.5mm 2.461 inch (screw terminal type)
Front panel of IP65 type is protected against water-splash and dust
Built-in Screw terminals
62.5
Screw terminal type is used for easy wiring and reducing additional cost for
2.461
48
1.890
accessories.
mm inch
0 setting instantaneous output operation
Multiple time ranges 1 s to 500 h (Max.)
Screw
8 different operation modes: (PM4H-A)
Pin type terminal type
Compliant with UL/CSA, CE and LLOYD
Product types
Contact Protective Rated
Type Operation mode Time range Terminal type Part number
arrangement construction operating voltage
11 pins PM4HA-H-AC240VW
100 to 240V AC
Screw terminal PM4HA-H-AC240VSW
11 pins PM4HA-H-DC125VW
48 to 125V DC
Screw terminal PM4HA-H-DC125VSW
IP65
11 pins PM4HA-H-24VW
24V AC/DC
8 operation modes
Screw terminal PM4HA-H-24VSW
Pulse ON-delay
11 pins PM4HA-H-DC12VW
Pulse Flicker
12V DC
Relay
Screw terminal PM4HA-H-DC12VSW
Pulse ON-flicker
PM4H-A Timed-out
Differential ON/OFF-delay (1) (2)
11 pins PM4HA-H-AC240V
2 Form C
100 to 240V AC
Signal OFF-delay
Screw terminal PM4HA-H-AC240VS
Pulse One-shot
PM4HA-H-DC125V
11 pins
Pulse One-cycle
48 to 125V DC
PM4HA-H-DC125VS
Screw terminal
IP50
11 pins PM4HA-H-24V
24V AC/DC
Screw terminal PM4HA-H-24VS
11 pins PM4HA-H-DC12V
12V DC
Screw terminal PM4HA-H-DC12VS
8 pins PM4HS-H-AC240VW
100 to 240V AC
Screw terminal PM4HS-H-AC240VSW
8 pins PM4HS-H-DC125VW
48 to 125V DC
Screw terminal PM4HS-H-DC125VSW
IP65
8 pins PM4HS-H-24VW
24V AC/DC
Screw terminal PM4HS-H-24VSW
8 pins PM4HS-H-DC12VW
12V DC
Relay 16 selectable
PM4HS-H-DC12VSW
Screw terminal
PM4H-S Power ON-delay Timed-out ranges
PM4HS-H-AC240V
8 pins
2 Form C
1s to 500h
100 to 240V AC
Screw terminal PM4HS-H-AC240VS
8 pins PM4HS-H-DC125V
48 to 125V DC
Screw terminal PM4HS-H-DC125VS
IP50
8 pins PM4HS-H-24V
24V AC/DC
Screw terminal PM4HS-H-24VS
8 pins PM4HS-H-DC12V
12V DC
Screw terminal PM4HS-H-DC12VS
8 pins PM4HM-H-AC240VW
100 to 240V AC
Screw terminal PM4HM-H-AC240VSW
8 pins PM4HM-H-DC125VW
48 to 125V DC
Screw terminal PM4HM-H-DC125VSW
IP65
PM4HM-H-24VW
8 pins
24V AC/DC
PM4HM-H-24VSW
Screw terminal
5 operation modes
(With instantaneous contact) Relay 8 pins PM4HM-H-DC12VW
12V DC
Power ON-delay Timed-out
Screw terminal PM4HM-H-DC12VSW
PM4H-M Power Flicker 1 Form C
8 pins PM4HM-H-AC240V
Power ON-flicker Instantaneous
100 to 240V AC
Screw terminal PM4HM-H-AC240VS
1 Form C
Power One-shot
Power One-cycle 8 pins PM4HM-H-DC125V
48 to 125V DC
Screw terminal PM4HM-H-DC125VS
IP50
8 pins PM4HM-H-24V
24V AC/DC
Screw terminal PM4HM-H-24VS
8 pins PM4HM-H-DC12V
12V DC
Screw terminal PM4HM-H-DC12VS
If you use this timer under harsh environment, please order above sealed type (IP65 type). IP65 type Protection dust and water jet splay on the front face.
09/2009
38
Analog
TimersPM4H-A/S/M
Time range
PM4H-A/PM4H-S/PM4H-M
Time unit
sec min hrs 10h
All types of PM4H timer have multi-time
Scale
range.
1 0.1s to 1s 0.1 min to 1 min 0.1h to 1h 1.0h to 10h
16 time ranges are selectable.
5 0.5s to 5s 0.5 min to 5 min 0.5h to 5h 5h to 50h
Control
1s to 500h (Max. range) is controlled.
time range
10 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h
50 5s to 50s 5 min to 50 min 5h to 50h 50h to 500h
Note: 0 setting is for instantaneous output operation.
Specifications
Type
PM4H-A PM4H-S PM4H-M
Item
Rated operating voltage 100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DC
Rated frequency 50/60Hz common (AC operating type)
Approx. 10VA (100 to 240V AC)
Rated power consumption Approx. 2.5VA (24V AC)
Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC)
Rated control capacity 5A 250V AC (resistive load)
Pulse ON-delay
Rating
Power ON-delay
Pulse Flicker
Power Flicker
Pulse ON-Flicker
Power ON-flicker
Operating mode Differential ON/OFF-delay (1) (2) Power ON-delay
Power One-shot
Signal OFF-delay
Power One-cycle
Pulse One-shot
(with instantaneous contact)
Pulse One-cycle
Time range 1s to 500h (Max.) 16 time ranges switchable
Operating time fluctuation 0.3% (power off time change at the range of 0.1s to 1h)
Time
Setting error 5% (Full-scale value)
accuracy
Voltage error 0.5% (at the operating voltage changes between 85 to 110%)
Note:1)
Temperature error 2% (at 20
C ambient temp. at the range of 10 to +50
C +14 to +122
F)
Timed-out 1 Form C
Contact arrangement Timed-out 2 Form C
Instantaneous 1 Form C
Contact
Contact resistance (Initial value) Max. 100m (at 1A 6V DC)
Contact material Silver alloy Au flash on Silver alloy
7
Mechanical (contact) 2 10
Life
5
Electrical (contact) 10 (at rated control capacity)
Allowable operating voltage range 85 to 110% of rated operating voltage (at 20
C coil temp.)
Between live and dead metal parts
Between input and output
Insulation resistance (Initial value) Min. 100M (At 500V DC)
Between contacts of different poles
Between contacts of same pole
Electrical
2,000Vrms for 1 min Between live and dead metal parts
function
2,000Vrms for 1 min Between input and output
Breakdown voltage (Initial value)
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole
Min. power off time 100ms
Max. temperature rise 55
C 131
F 65
C 149
F
Functional 10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
Vibration resistance
Destructive 10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
Mechanical
2
function Functional Min. 98m/s (4 times on 3 axes)
Shock resistance
2
Destructive Min. 980m/s (5 times on 3 axes)
Ambient temperature 10 to +50
C +14 to +122
F
Ambient humidity 30 to 85%RH (at 20
C 68
F, non-condensing)
Operating
condition Atmospheric pressure 860 to 1,060hPa
Ripple factor (DC type) 20%
Protective construction IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>
Others 100g 3.527 oz (Pin type)
Weight
110g 3.880 oz (Screw terminal type)
Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple
factor for DC), 20C 68F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes 10ms.
09/2009
39
Analog
Timers