VDE PQ 1a 5A small size power PQ RELAYS relay for interface FEATURES TYPICAL APPLICATIONS 1. Compact and slim 1. Programmable controllers 20 mm (L) 10 mm (W) 16 mm (H) 2. Interface relays for Factory .787 inch (L) .394 inch (W) .630 inch Automation and Communication (H) slim type equipment 2. Twin contact structure 3. Output relays for measuring Gold-clad twin (bifurcated) contacts equipment, timers, counters and provide high reliability. temperature controllers 3. High capacity and small size This small package can provide high 5 A capacity. RoHS compliant 4. High sensitivity with 200 mW nominal operating power 5. 8,000 V surge breakdown voltage Despite the compact size, between contact and coil surge resistance of 8,000 V has been achieved. The relay has low susceptibility to noise. 6. Outstanding shock resistance. 2 Functional shock resistance: 294 m/s 7. Most suitable for PLC output and internal device output relays. 8. Sealed type 9. Sockets are available. ORDERING INFORMATION PQ 1a Contact arrangement 1a: 1 Form A (Bifurcated) Nominal coil voltage (DC) 3, 5, 6, 9, 12, 18, 24 V Notes: 1. Certified by UL, CSA, VDE and SEMKO 2. TV approved type is available. TYPES Contact arrangement Nominal coil voltage Part No. 3V DC PQ1a-3V 5V DC PQ1a-5V 6V DC PQ1a-6V 1 Form A 9V DC PQ1a-9V (Bifurcated) 12V DC PQ1a-12V 18V DC PQ1a-18V 24V DC PQ1a-24V Standard packing: Carton: 100 pcs. Case: 500 pcs. * For sockets, see page 88. ASCTB206E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/PQ RATING 1. Coil data Nominal operating Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating current Max. applied voltage voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power 10% (at 20C 68F) 3V DC 66.7mA 45 180%V of 5V DC 40mA 125 nominal voltage 6V DC 33.3mA 180 75%V or less of 5%V or more of (at 20C 68F) 9V DC nominal voltage nominal voltage 22.2mA 405 200mW (Initial) (Initial) 130%V of 12V DC 16.7mA 720 nominal voltage 18V DC 11.1mA 1,620 (at 70C 158F) 24V DC 8.3mA 2,880 2. Specications Characteristics Item Specications Arrangement 1 Form A (Bifurcated) Contact Contact resistance (Initial) Max. 50 m (By voltage drop 6 V DC 1A) Contact material Au-clad AgNi type Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC Max. switching power (resistive load) 1,250 VA, 150 W Max. switching voltage 250 V AC, 110 V DC (0.3 A) Rating Max. switching current 5 A Nominal operating power 200 mW 1 Min. switching capacity (Reference value)* 100A 100mV DC Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.) Breakdown voltage (Initial) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.) Surge breakdown Between contacts and coil 8,000 V 2 Electrical voltage (Initial)* characteristics Max. 45C (By resistive method, nominal coil voltage applied to the coil, contact carrying Temperature rise (coil) current: 5 A, at 70C) Operate time (at 20C 68F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.) Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time.) Release time (at 20C 68F) (Initial) (without diode) 2 Functional 294 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive 980 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 2.0 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 3.5 mm 7 Mechanical Min. 210 (at 180 times/min.) Expected life 5 5 5 Electrical (at 20 times/min.) Min. 210 (5 A 125 V AC), Min. 10 (5 A 250 V AC), Min. 10 (5 A 30 V DC) Ambient temperature: 40C to 70C 40F to 158F 3 Conditions for operation, transport and storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Conditions Max. operating speed (at rated load) 20 times/min. Unit weight Approx. 7 g .25 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1. Max. switching capacity 2. Operate & release time 3. Coil temperature rise Tested sample: PQ1a-24V, 25 pcs. Measured portion: Inside the coil Contact carrying current: 5 A 100 70 60 8 50 AC resistive load 10 50C 6 40 5 Operate time 30 4 Max. 1 Min. 20 DC resistive load Max. Min. 70C 2 0.3 10 Release time 0 0 100 110 120 130 140 150 160 10 30 100 250 1,000 80 100 120 150 Coil applied voltage, %V Coil applied voltage,%V Contact voltage, V ASCTB206E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ Contact current,A Operate & release time, ms Temperature rise,C