Pan-Way Above Floor Raceway System SPECIFICATION SHEET specifications Above Floor Raceway* 6 Foot Base and Cover Above Floor Raceway non-metallic multi-channel surface raceway 6 Foot: AFR4BCBL6 shall be used to route, protect, and conceal data, voice, video, fiber optic and power cabling. The raceway shall be listed as suitable for Above Floor Raceway Fittings* use in applications up to 600 volts between conductors by Fittings Coupler Underwriters Laboratories, Inc. per standard 5A, and by Canadian Fitting: AFR4CCBL Standards Association, Inc. per 22.2 no. 62.1-03, when screw secured and installed per instructions. A full line of fittings is Transition to available as well as a junction box to install a variety of T70 Fitting: AFR4TRT70BL communication and electrical devices. Four channel design Right Angle separates cable types. Standard screw-on faceplates for data and Fitting: AFR4RABL power terminations shall be available. Above floor raceway will be manufactured from impact-resistant material with flammability rating End Cap Fitting: AFR4ECBL of V-0 and must be tamper resistant yet, also allow access for Junction Box: AFR4JB2SBL moves, adds and changes. Above Floor Raceway finish shall be pure color, resist scratches and dents, will not peel or corrode and Wall Transition be available in three standard colors. Above Floor Raceway shall be Fitting: AFR4WTRBL optimized for use with the Panduit Pan-Net and Net-Key Communication Systems. Table Leg Fitting: AFR4TBLGBL Faceplates and Accessories technical information Rectangular GFCI Material: Rigid PVC Outlet Faceplate*: CPGBL-2G Flammability: UL94V-0 GFCI Adapter: CFG4BL FT4 GFCI Netkey Voltage rating: UL-5A 600VAC Adapter: NK4RMFBL CSA C22.2 No. 62.1-03 600V 106 Style Outlet Approvals: UL Listed 95425 (raceway) Faceplate*: CP106BL-2G UL Listed E116129 (fittings) 106 Adapter: CF1064BLY NEC: Article 388 106 Netkey Load rating: 2,000 lbs. Adapter: NK4106MFBL T70 Parts* key features and benefits T-70 Base 6 foot ADA Compliant Meets 2010 American Disability Association standards by design length: T70BBL6 T-70 Cover 6 foot 1 bend radius control Cables in the raceway will satisfy the minimum 1 bend radius fittings requirement, Preventing the potential degradation of cable performance length: T70CBL6 meets TIA/EIA Standard and many warranty requirements T-70 End Cap Tamper resistant Difficult for untrained personnel to enter the raceway or remove Fitting: T70ECBL faceplates provides security for communication cabling and safety for * Product listed in Black (BL). power cabling For other colors, replace BL with IW Designer profile Aesthetically pleasing and matches a wide variety of decors with three (International White) or OS (Office Slate). standard color options available: IW (International White), BL (Black) or OS (Office Slate) Non-metallic Lightweight raceway reduces installer fatigue solid color throughout construction profile will not chip peel, rust, corrode, or scratch easy to cut reducing the need for special cutting devices easy to snap together base and cover high impact resistance durable applications Pan-Way Above Floor Surface Raceway is a multi-channel raceway which provides solutions for routing low voltage, fiber optic and/or power cabling over floors. Above Floor raceway can mount NEMA standard screw-on faceplates directly to the junction box and can transition to Panduit s T-70 raceway for cable routing along walls. www.panduit.com Pan-Way Above Floor Raceway Wire Fill Chart electrical cables Data Grade Cables Coax Cables Fiber Optic 14 12 10 24 AWG 24 AWG 24 AWG 24 AWG 24 AWG 24 AWG 24 AWG THN/THWN/T90 Cat 5eP Cat 5eR Cat 6 Cat 6A Cat 6A Cat 6A Cat 6A (SD) RG6 RG59/u 2-Strand 0.111 0.13 0.164 0.193 0.225 0.24 0.289 0.3 0.33 0.24 0.275 0.242 0.175 Fill Fill Fill Fill Fill Fill Fill Fill Fill Fill Fill Fill Max Max Max Spec Max Spec Max Spec Max Spec Max Spec Max Spec Max Spec Max Spec Max Spec Max Spec Max Raceway type and Area configuration (in 2) UL Temp Rise Test 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% AFR4 Outer Channel 0.3370 21 15 10 5 7 3 5 3 4 2 3 2 3 2 2 3 4 2 3 3 4 6 8 (with screws) See Fig. A AFR4 Inner Channel 0.3838 24 17 11 5 8 4 6 3 5 2 4 2 3 2 3 3 5 3 4 3 5 6 10 See Fig. B Fittings End Cap Coupler Wall Transition AFR4ECBL AFR4CCBL AFR4WTRBL Table Leg Right Angle T70 Transition Junction Box AFR4TBLGBL AFR4RABL AFR4TRT70BL AFR4JB2SBL Dimensions are in inches. Dimensions in brackets are metric. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty 2019 Panduit Corp. ALL RIGHTS RESERVED. Visit us at www.panduit.com SRSP33--WW-ENG Contact Customer Service by email: cs panduit.com replaces SRSP32--WW-ENG 8/2019 or by phone: 800.777.3300