18900 Panduit Drive TDS: GMY2-STE Tinley Park, IL 60487 Effective Date: 17Jul12 Customer Service: 800-777-3300 Revision: 2 Technical Data Sheet Tamper-Evident Silver Polyester Film This specification is intended to outline the physical properties of PANDUITs pressure sensitive tamper-evident silver polyester material and include the following part numbers and printable material identifiers: Part Number Prefixes Printable Material Suffixes PEL*Y1C AAL PRODUCT SPECIFICATIONS: Description: Material is RoHS compliant (European Union directive 2002/95/EC). Material is a top coated polyester film with a pressure sensitive adhesive. This material is halogen free. Print Methods: This material is recommended for laser printing. Adhesive: Acrylic based, pressure sensitive permanent adhesive. Standard Colors: Matte Silver Thickness: 3.5 +/- 0.4 mils (substrate and adhesive) Service Temperature Range: -40F to 302F (-40C to 150C). Tamper evident feature of this product becomes permanently non-functional after application over 104F (70C) temperature. Minimum Application Temperature: 50F (10C) Storage Conditions: Store at 70F (21C) and 50% Relative Humidity. PROPERTIES: PERFORMANCE: Peel Adhesion to Stainless Steel: Product shows tampering when removal is attempted by leaving a checkerboard pattern on the application surface. (PSTC-101, 72 hour dwell) Shear Adhesion: 2 hours minimum (PSTC-107, Procedure A) Tensile Strength: MD 48 +/- 4.8 lbs./inch width (PSTC-131) TD 74 +/- 7.4 lbs./inch width (PSTC-131) MD 80% +/- 15% (PSTC-131) Elongation: TD 75% +/- 15% (PSTC-131) UV Resistance: *3000 hours. Matte coating turns yellow. (ASTM G154) Elevated Temperature Exposure: After 8 hours at 275F (135C) there was no deterioration of the substrate. 2 Tack: 400 - 900 g/cm (ASTM D-2979-71) *3000 hours equates to 5 years of assimilated outdoor UV exposure. Page 1 of 2 2005 PANDUIT Corp TDS: GMY2-STE 18900 Panduit Drive TDS: GMY2-STE Tinley Park, IL 60487 Effective Date: 17Jul12 Customer Service: 800-777-3300 Revision: 2 Technical Data Sheet CHEMICAL/SOLVENT RESISTANCE: The testing was conducted at room temperature. Samples were printed on a laser printer. The printed samples were immersed in the specified reagents for 5 immersions using the following cycle: a 10 minute immersion time followed by a 30 minute recovery time. After the final immersion, samples were rubbed 10 times with a lint free gauze. The samples were visually observed for any loss in print legibility. Chemical/Solvent Visual Observation Distilled Water No effect Mineral Spirits No effect Toluene Loss in print legibility Isopropyl Alcohol No effect Methanol No effect Acetone Significant print smear Methyl Ethyl Ketone Loss in print legibility 1,1,1 Trichloroethane Loss in print legibility Freon TF No effect Super Agitene No effect Jet A Fuel No effect Arco Truslide 68 No effect SAE 30 Motor Oil No effect LIMITED WARRANTY All PANDUIT Identification Solution Products (except for Software programs) are warranted to be free from defects in material and workmanship at the time of sale but our obligation under this warranty is limited to replacement of the product proved to be defective within 6 months from the date of sale, or in the case of printers, within 90 days from the date of sale. This warranty is void if the products or printers are modified, altered or misused in any way. Use of PANDUIT printers with any product other than the specified PANDUIT products for which the printer was designed constitutes misuse. Before using, the user shall determine the suitability of the product for its intended use and user assumes all risk and liability whatsoever in connection therewith. The foregoing may not be altered except by an agreement signed by officers or seller and manufacturer. NEITHER PANDUIT NOR SELLER SHALL BE LIABLE FOR ANY OTHER INJURY, LOSS OR DAMAGE, WHETHER DIRECT OR CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR THE INABILITY TO USE THE PRODUCT OR THE PRINTER. THIS WARRANTY IS MADE IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF PARTICULAR USE ARE SPECIFICALLY EXCLUDED. The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a guide or use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. This publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc. Page 2 of 2 2005 PANDUIT Corp TDS: GMY2-STE