Mini-Com TX6A 10Gig UTP Coupler Module and Patch Panel SPECIFICA TION SHEET TX6A 10Gig UTP specifications Copper Cabling System Category 6A/Class E , 8-position, female to female, UTP Mini-Com TX6A UTP A coupler module shall provide easy plug and play pass Copper Modules through connectivity. Coupler module shall act as one Coupler Module: CC6X88 connecting hardware component in the channel. Coupler Mini-Com TX6A 10Gig UTP modules shall be available individually or installed in a Coupler Patch Panel 24-port flat patch panel. Couplers shall be compatible with 6 or 8-position RJ45 UTP patch cords with T568A 24-port, 1 RU: CP246X88BL and T568B wiring schemes. TX6A 10Gig UTP Patch Cords with MaTriX Technology technical information CM (foot lengths): UTP6A CM (meter lengths): UTP6A M Category 6A/Class E Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6A A channel performance: TX6A-SD 10Gig UTP Patch and ISO11801 Class E standards for supporting 10GBASE-T A Cords with MaTriX Technology transmission over twisted pair cabling systems in a 4-connector configuration up to 100 meters CM (ft lengths): UTP6ASD BU CM (m lengths): UTP6ASD MBU One coupler can be used per channel while maintaining Category LSZH (m lengths): UTP6ASDL M 6A/Class E performance A Mini-Com Angled Modular FCC and Meets ANSI/TIA-1096-A contacts plated with 50 microinches Patch Panels ANSI/TIA compliance: of gold for superior performance 24-port, 1 RU: CPPA24FMWBLY IEC compliance: Meets IEC 60603-7 48-port, 2 RU: CPPA48FMWBLY 72-port, 2 RU: CPPLA72WBLY PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications Mini-Com Flat Modular RoHS compliance: Compliant Patch Panels c(UL)US rated: UL 1863, CSA Standard C22.2 24-port, 1 RU: CPP24FMWBLY 48-port, 2 RU: CPP48HDWBLY 48-port, 1 RU: CPP48FMWBLY key features and benefits 72-port, 2 RU: CPP72FMWBLY 100% performance tested Confidence that each coupler will deliver the critical Tools and Accessories electrical performance requirements Jack module Modular Couplers snap in and out of all Mini-Com Faceplates, termination tool: TGJT or EGJT Modular Patch Panels and industrial bulkheads for easy Wire snipping tool: CWST moves, adds and changes Wire stripping tool: CJAST Clear dust cap: MDC-C RJ45 interface Industry standard interface provides a quick and easy Blockout device: PSL-DCJB- plug and play connection to RJ45 patch cords Phone icons: CIPIW-C++ backwards compatible Data icons: CIDIW-C++ Identification Can be clearly identified with optional labels and icons for For additional colors, add suffix: BL (Black), IW (Off White), BU (Blue), RD (Red), GR port identification (Green), OR (Orange), IG (International Gray), Populated patch panel version Factory installed 24-port patch panel mounts to standard or YL (Yellow). EIA 19 or 23 racks for greater system flexibility For lengths 3 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length Block out device (optional) Provides a simple and secure method to control access to designation in the part number to the desired length. For standard cable colors other than data ports while not in use Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), applications OR (Orange) or VL (Violet). For example, UTP6A15BU = blue, 15-foot patch cord. Mini-Com TX6A 10Gig UTP Coupler With certified performance to the For lengths 1, 1.5, 2 to 7 (one meter increments), 10, 15, 20 meters, change the Modules and Patch Panels are a component ANSI/TIA-568-C.2 Category 6A and ISO length designation in the part number to the of the TX6A 10Gig UTP Copper 11801 Class E standards, this system will A desired length. For standard cable colors Cabling System. This end-to-end system support the following applications: other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), is interoperable and backwards compatible, Ethernet 10BASE-T, 100BASE-T OR (Orange) or VL (Violet). LSZH patch cable providing design flexibility to protect network (FastEthernet), 1000BASE-T available in Off White or BU (Blue). For investments well into the future. Couplers (Gigabit Ethernet) example, UTP5ASD5MBU = blue, 5-meter patch cord. are designed to perform as a single connector 155 Mb/s ATM, 622 Mb/s ATM, To designate color other than Red, add in the channel. One coupler can be used per 1.2 Gb/s ATM suffix BL (Black), BU (Blue), YL (Yellow), channel while maintaining Category 6A/Class Token Ring 4/16 GR (Green), OR (Orange), IW (Off White) or E performance. Couplers are a reliable, Digital video and broadband/baseband IG (International Gray) at the end of the part A number. 10/package. modular solution, ideal when setting up analog video ++To designate color other than IW (Off White), networks in a testing environment or Voice over Internet Protocol (VoIP) replace IW with EI (Electric Ivory), during a planned system upgrade. IG (International Gray), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet) in the part number. www.panduit.com 100/package. Mini-Com TX6A 10Gig UTP Coupler Module and Patch Panel Test Results Mechanical Test Test Method Measurement Required Performance Normal Force Load (grams) > 100 Vibration IEC 512-6d Circuit Resistance Change (mOhms) < 40 Shock IEC 512-6c Contact Disturbance (microsecond) < 5 Durability IEC 512-9a Circuit Resistance Change (mOhms) < 40 Mating/Unmating IEC 512-13b Mating Force (N) < 20 Unmating Force (N) < 20 Termination Cycles IEC 352 Number of Cycles >20 Mechanical Test Test Method Measurement Required Performance Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20 Dielectric Withstand Voltage IEC 512-4a 1000VAC, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Mechanical Test Test Method Measurement Required Performance Temperature Life IEC 512-9b Circuit Resistance Change (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance Change (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance Change (mOhms) < 40 Climactic Sequence IEC 512-11a Circuit Resistance Change (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance Change (mOhms) < 40 Mini-Com TX6A 10Gig UTP Coupler Module Mini-Com 24-Port Category 6A Coupler Patch Panel 1.13 (28.6) Compatible with Industrial Bulkhead (IAEBH) Compatible with Mini-Com Faceplates and Modular Patch Panels 1.72 (46.7) 0.71 18.06 19.00 0.62 1.13 (482.6) 15.86 28.64 Dimensions are in inches Dimensions in brackets are metric WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2015 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com COSP251--WW-ENG 4/2015 or by phone: 800.777.3300 and reference COSP251