Mini-Com TX6A 10Gig Shielded Jack Modules SPECIFICA TION SHEET TX6A 10Gig Shielded specifications Copper Cabling System Category 6A/Class E , 8-position, shielded jack module shall terminate 4-pair, 22 26 AWG, A Mini-Com TX6A 10Gig 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool. Shielded Shielded Jack Modules jack modules shall use a forward motion termination method to optimize performance by Jack module: CJS6X88TG*Y maintaining cable pair geometry while eliminating conductor untwist. The termination cap shall Shuttered jack be color-coded blue to designate Category 6A performance and shall include a universal label module: CJSH6X88TG*Y coded for T568A and T568B wiring schemes. The Mini-Com TX6A 10Gig Shielded Jack Marine jack module: CJSM6X88TGY Module must be installed as part of the TX6A 10Gig Shielded Copper Cabling System to achieve IEEE 10GBASE-T certified performance. Tools and Accessories Jack module technical information termination tool: EGJT-1 or TGJT Wire snipping tool: CWST Category 6A/Class E Exceeds ANSI/TIA-568.2-D Category 6A and ISO 11801 Class E channel requirements for A A Wire stripping tool: CJAST performance: supporting 10GBASE-T transmission over twisted pair cabling systems in a 4-connector Clear dust cap: MDC-C configuration up to 100 meters at swept frequencies 1 to 500 MHz Block out device: PSL-DCJB- ++ Meets ANSI/TIA-568.2-D and ISO 11801 Category 6A component requirements at swept fre- Phone icons: CIPIW-C ++ quencies up to 500 MHz Data icons: CIDIW-C FCC compliance: Complies with ANSI/TIA-1096-A (formerly FCC Part 68) contacts plated with *To designate color, add BU (Blue), RD (Red), WH (White), YL (Yellow), GR (Green) or VL (Violet). 50 microinches of gold For part number CJS6X88TGY (no designation), IEC compliance: Meets IEC 60603-7 and IEC 60512-99-001 the color is black. To designate color other than Red, add suffix Operating temperature: -10 C to 65 C (14 F to 149 F) BL (Black), BU (Blue), YL (Yellow), GR (Green), OR (Orange), IW (Off White), or IG (International PoE compliance: Rated for 2500 cycles with IEEE 802.3af / 802.3at and 802.3bt type 3 and type 4 for up to Gray) at the end of the part number. 10/package. ++ 100W To designate color other than IW (Off White), replace IW with EI (Electric Ivory), IG (International Gray), UL Listed: UL 1863 (Use as communications circuit accessory) BL (Black), BU (Blue), RD (Red), YL (Yellow), UL 2043 (Suitable for use in air-handling spaces) GR (Green), OR (Orange), or VL (Violet) in the part number. 100/package. RoHS compliance: Compliant Contact customer service for bulk packaged and/or keyed jack modules. Panduit recommends installing Conductor Standard wire cap compatible with 22 26 AWG solid or stranded cable with conductor shielded jack modules in Mini-Com All Metal termination range: insulation diameters of 0.060 in. max and overall cable O.D. 0.200 in. to 0.330 in. Modular Patch Panels. Marine jack module wire cap compatible with 22 AWG solid or stranded cable with 0.071 in (1.80mm) maximum insulated conductor outside diameter cable key features and benefits 100% performance tested Confidence that each jack module will deliver the critical electrical performance requirements Utilizes enhanced Optimizes performance by eliminating conductor untwist and reduces installation time Giga-TX Technology and expense Integral shield Provides a 360 conductive path to ground shielded jack module with no additional assembly required Snap in grounding Shield provides seamless bonding of the jack module with Mini-Com All Metal Modular Patch Panels Modular Shielded jack modules snap in and out of all Mini-Com Faceplates, Metal Modular Patch Panels and Surface Mount Boxes for easy moves, adds, and changes Individually serialized Marked with quality control number for future traceability Identification Can be clearly identified with optional labels and icons for port identification High density Able to support 48 ports in 1RU density Shuttered version Integrated spring shuttered door keeps out dust and debris of un-mated RJ45 jack (optional): modules automatically Marine compatible Terminates to TX7000 Shielded MUD-Resistant Marine Copper Cable (S/FTP), which version available includes a durable flame-, oil-, UV- and MUD-resistant cable jacket ideal for use in harsh environments encountered in marine applications including ship and offshore/onshore units Termination EGJT-1 termination tool ensures conductors are fully terminated by utilizing a smooth for- tools (optional) ward motion without impact on critical internal components for maximum reliability TGJT termination tool ideal for high volume installations Block out device (optional) Provides a simple and secure method to control access to data ports while not in use Grounding availability Able to ground anywhere. For grounding shielded jack modules not installed in a Mini-Com All Metal Modular Patch Panel, use the shielded jack module grounding kit, part number CJSGK-XY applications Mini-Com TX6A 10Gig Shielded Jack Modules are a ISO 11801 Class E , IEEE 802.3an-2006 and ANSI/TIA- A component of the TX6A 10Gig Shielded Copper Cabling 568.2-D Category 6A standards, this system will support System. This end-to-end system provides a cost effective high bandwidth applications with data centers and medium for ensuring that network bandwidth needs are connections to high end workstations such as stacking easily met today and tomorrow. This shielded system switches and switch-to-switch links, storage area networks, provides high performance, excellent EMI suppression aggregation of Gigabit Ethernet channels, real-time intensive and aids in secure data transmission. The Panduit solution financial transactions, streaming video, animation, scientific helps ensure organizations efficiently and reliably meet their modeling and medical imaging. data transmission needs. With certified performance to the www.panduit.com Mini-Com TX6A 10Gig Shielded Jack Modules Test Results Mechanical Test Test Method Measurement Test Results Normal Force Load (grams) > 100 Vibration IEC 512-6d Circuit Resistance (mOhms) < 40 Shock IEC 512-6c Contact Disturbance (microseconds) < 5 Durability IEC 512-9a Circuit Resistance (mOhms) < 40 Mating/Un-mating IEC 512-3b Mating Force (N) < 20 Un-mating Force (N) < 20 Termination Cycles IEC 352 Number of Cycles > 20 Mating Cycles IEC 60603-7 Number of Plug Insertions > 2500 Electrical Test Test Method Measurement Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20 Dielectric Withstand Voltage IEC 512-4a 1000 VAC, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Electrical Test Test Method Measurement Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 Shielded Jack Module and Standard Shuttered Shielded Jack Module and Wire Cap Standard Wire Cap 0.73 0.74 (18.64) (18.77) 0.62 0.62 1.42 (15.87) 1.50 (15.87) (36.18) (38.13) Dimensions are in inches (Dimensions in parenthesis are metric) WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2019 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com COSP230--WW-ENG or by phone: 800.777.3300 4/2019