Mini-Com TX5e UTP 28/30 AWG Jack Modules SPECIFICATION SHEET specifications TX5500 UTP Copper Cabling System Category 5e/Class D, 8-position, UTP jack module shall terminate 4-pair, 28 AWG solid/stranded and 30 AWG solid, 100 ohm unshielded Mini-Com TX5e UTP Jack Modules twisted pair cable and shall not require use of a punchdown tool. Jack module: CJT5E88TGIW* UTP jack modules shall use a forward motion termination method to TX5e UTP 28 AWG Patch Cords optimize performance by maintaining cable pair geometry while eliminating conductor untwist. The termination cap shall be Feet: UTP28CH** color-coded yellow to designate Category 5e performance and shall Meters: UTP28CH***M include a universal label coded for T568A and T568B wiring schemes. Mini-Com Angled Modular Patch Panels technical information 24-port, 1 RU: CPPLA24WBLY 48-port, 2 RU: CPPLA48WBLY Category 5e/Class D Exceeds channel requirements of ANSI/TIA-568-C.2 Category 5e and Mini-Com Flat Modular channel and ISO 11801 Class D standards at swept frequencies 1 to 100 MHz Patch Panels component performance: Exceeds component requirements of ANSI/TIA-568-C.2 Category 5e and 24-port, 1 RU: CPPL24WBLY ISO 11801 Class D standards at swept frequencies 1 to 100 MHz 48-port, 2 RU: CPPL48WBLY For additional modular patch panels and FCC and ANSI Meets ANSI/TIA-1096-A contacts plated with 50 microinches punchdown patch panels, visit www.panduit.com compliance: of gold for superior performance Tools and Accessories IEC compliance: Meets IEC 60603-7 Jack module RoHS compliance: Compliant termination tool: EGJT or TGJT PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications Wire snipping tool: CWST Wire stripping tool: CJAST c(UL)US listed: UL 1863, CSA standard C22.2 Clear dust cap: MDC-C Conductor termination Wire cap compatible with 28 AWG solid/stranded and 30 AWG solid cable with Blockout device: PSL-DCJB- range: conductor insulation diameters of 0.025 in. max. and overall cable O.D. 0.120 in. Phone icons: CIPIW-C+ to 0.185 in. Data icons: CIDIW-C+ *To designate color other than IW (Off White), replace IW suffix with EI (Electric Ivory), IG (International Gray), key features and benefits AW (Arctic White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange), or VL (Violet). 100% performance tested Confidence that each jack module will deliver the critical electrical **For lengths 1 to 20 feet (increments of one foot), performance requirements change the length designation in the part number to the desired length. For standard cable colors other Utilizes enhanced Optimizes performance by eliminating conductor untwist and that Off White, add suffix BL (Black), BU (Blue), GR (Green), RD (Red), YL (Yellow), OR (Orange), or VL Giga-TX Technology reduces installation time and expense (Violet). For example, the part number for a blue Improved termination cap Conductor retention slots simplify jack module termination 15-foot patch cord is UTP28CH15BU. ***For lengths 0.5 to 6 meters (increments of half Modular UTP jack modules snap in and out of all Mini-Com Faceplates, Modular meter). For standard cable colors other than Off White, Patch Panels and Surface Mount Boxes for easy moves, adds, and changes add suffix BL (Black), BU (Blue), GR (Green), RD (Red), YL (Yellow), OR (Orange), or VL (Violet). For True strain relief Controls cable bend radius for long-term installed performance example, the part number for a blue 5-meter patch cord is UTP28CH5MBU. Individually serialized Marked with quality control number for future traceability To designate color other than Red, add suffix Black (BL), Blue (BU), Yellow (YL), Green (GR), RJ45 interface Industry standard interface provides a quick and easy plug and play Orange (OR), Off White (IW) or International Gray connection to RJ45 patch cords backwards compatible (IG) at the end of the part number. 10/package. +To designate color other than IW (Off White), replace Identification Can be clearly identified with optional labels and icons for port Identification IW with EI (Electric Ivory), IG (International Gray), BL (Black), BU (Blue), RD (Red), YL (Yellow), Termination tools (optional) EGJT termination tool ensures conductors are fully terminated by utilizing a GR (Green), OR (Orange), or VL (Violet) in the part smooth forward motion without impact on critical internal components for number. 100/package. maximum reliability TGJT termination tool ideal for high volume installations Contact customer service for bulk packaged jack modules and patch cords. Block out device (optional) Provides a simple and secure method to control access to data ports while not in use applications Mini-Com TX5e UTP Jack Modules are a component of the TX5500 UTP Copper Cabling System. This end-to-end system provides Gigabit Ethernet performance with usable bandwidth beyond 100 MHz. With certified performance to the ANSI/TIA-568-C.2 Category 5e and ISO 11801 Class D Edition 2.1 standards, this system will support the following applications: Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet) 155 Mb/s ATM, 622 Mb/s ATM Token ring 4/16 Voice/data systems Voice over Internet Protocol (VoIP) www.panduit.com Mini-Com TX5e UTP 28/30 AWG Jack Modules test results Mechanical Test Test Method Measurement Typical Test Results Normal Force Load (grams) >100 Vibration IEC 512-6d Circuit Resistance (mOhms) <40 Shock IEC 512-6c Contact Disturbance (microseconds) <5 IEC 512-9a Circuit Resistance (mOhms) <40 Durability IEC 512-13b Mating Force (N) <20 Mating/Unmating Un-mating Force (N) <20 Termination Cycles IEC 352 Number of Cycles >20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) <20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) >500 Environmental Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) <40 Humidity IEC 512-11c Circuit Resistance (mOhms) <40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) <40 Climactic Sequence IEC 512-11a Circuit Resistance (mOhms) <40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) <40 Strain Relief Clip Wire Cap Module Housing Jack Module 0.71 (18.06) 0.62 1.49 (15.87) (37.90) Dimensions are in inches (Dimensions in parenthesis are metric) WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2012 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com COSP223--WW-ENG or by phone: 800-777-3300 and reference COSP223--WW-ENG 8/2012