Easy Selection Guide for Pan-Term Terminals RING TERMINALS FORK TERMINALS LOCKING FORK TERMINALS WIRE STUD NON- VINYL NYLON NON- VINYL NYLON NON- VINYL NYLON u u RANGE SIZE INSULATED INSULATED INSULATED INSULATED INSULATED INSULATED INSULATED INSULATED INSULATED 4 P18-4R PV18-4R PN18-4R 6 P18-6R PV18-6R PN18-6R P18-6F PV18-6F PN18-6F P18-6LF PV18-6LF PN18-6LF 8 P18-8R PV18-8R PN18-8R P18-8F PV18-8F PN18-8F P18-8LF PV18-8LF PN18-8LF 10 P18-10R PV18-10R PN18-10R P18-10F PV18-10F PN18-10F P18-10LF PV18-10LF PN18-10LF 22-18 1/4 P18-14R PV18-14R PN18-14R P18-14F PN18-14F 1/2 P18-12R PV18-12R PN18-12R 5/16 P18-56R PV18-56R PN18-56R 3/8 P18-38R PV18-38R PN18-38R 4 P14-4R PV14-4R PN14-4R 6 P14-6R PV14-6R PN14-6R P14-6F PV14-6F PN14-6F P14-6LF PV14-6LF PN14-6LF 8 P14-8R PV14-8R PN14-8R P14-8F PV14-8F PN14-8F P14-8LF PV14-8LF PN14-8LF 10 P14-10R PV14-10R PN14-10R P14-10F PV14-10F PN14-10F P14-10LF PV14-10LF PN14-10LF 16-14 1/4 P14-14R PV14-14R PN14-14R P14-14F PN14-14F 1/2 P14-12R PV14-12R PN14-12R 5/16 P14-56R PV14-56R PN14-56R 3/8 P14-38R PV14-38R PN14-38R 6 P10-6R PV10-6R PN10-6R P10-6F PV10-6F PN10-6F P10-6LF PV10-6LF PN10-6LF 8 P10-8R PV10-8R PN10-8R P10-8F PV10-8F PN10-8F P10-8LF PV10-8LF PN10-8LF 10 P10-10R PV10-10R PN10-10R P10-10F PV10-10F PN10-10F P10-10LF PV10-10LF PN10-10LF 1/4 P10-14R PV10-14R PN10-14R P10-14F PV10-14F PN10-14F P10-14LF PV10-14LF PN10-14LF 12-10 1/2 P10-12R PV10-12R PN10-12R 5/16 P10-56R PV10-56R PN10-56R 3/8 P10-38R PV10-38R PN10-38R u Expanded wire range for non-insulated ring terminals type P18 = 22-16, type P14 = 18-14, and type P10 = 14-10. FEMALE DISCONNECTS NYLON INSULATED WIRE JOINTS VINYL NYLON WIRE RANGE CMA RANGE PART WIRE TAB NON- VINYL BARREL BARREL NYLON MIN. MAX. MIN. MAX. NUMBER RANGE SIZE INSULATED BARREL INSULATED INSULATED FULLY INSULATED (Ins. Grip) (Ins. Grip) INSULATED* 2 24 2 16 808 5160 JN224-318 .110 x .032 DNF18-110 DNF18-110FIB 2 22 2 16 1284 5160 JN218-216 .110 x .020 DNF18-111 DNF18-111FIB 4 18 2 12 6480 14750 JN418-212 .187 x .032 D18-187 DV18-187B DVF18-187 DNF18-187 DNF18-187FIB 22-18 .187 x .020 D18-188 DV18-188B DVF18-188 DNF18-188 DNF18-188FIB 3 14 4 12 10320 26120 JN314-412 .205 x .032 DV18-205B DVF18-205 DNF18-205 DNF18-205FIB .205 x .020 DV18-206B DVF18-206 DNF18-206 DNF18-206FIB .250 x .032 D18-250 DV18-250B DVF18-250 DNF18-250 DNF18-250FIB BUTT .110 x .032 DNF14-110 SPLICES .110 x .020 DNF14-111 .187 x .032 D14-187 DV14-187B DVF14-187 DNF14-187 DNF14-187FIB WIRE NON- VINYL NYLON 16-14 .187 x .020 D14-188 DV14-188B DVF14-188 DNF14-188 DNF14-188FIB RANGE INSULATED INSULATED INSULATED .205 x .032 DV14-205B DVF14-205 DNF14-205 DNF14-205FIB .205 x .020 DV14-206B DVF14-206 DNF14-206 DNF14-206FIB 26-22 BS22* BSN22* .250 x .032 D14-250 DV14-250B DVF14-250 DNF14-250 DNF14-250FIB 22-18 BS18 BSV18X BSN18 12-10 .250 x .032 D10-250 DV10-250 DNF10-250FI 16-14 BS14 BSV14X BSN14 *For premium nylon replace DNF with DPF. 12-10 BS10 BSV10X BSN10 Stud Size Chart with Panduit Bolt Hole Sizes *Not UL Listed or CSA Certified. Standard FERRULE Stud END SLEEVES Size 5 6 8 10 1/4 5/16 3/8 7/16 1/2 PART WIRE RANGE STYLE NUMBER Stud Size 14 DIN FSD80-12 .127 .138 .164 .190 .250 .312 .375 .438 .500 Decimal 8 DIN FSD83-12 Equiv. 10 DIN FTD82-14 Terminal 1 NON-INS F87-18 .130 .147 .173 .204 .270 .343 .392 .456 .531 Hole Dia. Note: All warranties, including merchantability and fitness for a particular purpose, are excluded. User is responsible to determine suitability of product for intended use. FERRULE KITS Panduit Dry-Shrink Heat Shrink Tubing PART Recommended Tubing Size for Common Wire Types WIRE RANGE STYLE NUMBER Recommended tubing size WIRE RECOMMENDED 24-18 DIN KP-FSD1 STYLE RANGE TUBING SIZE for use with Panduit 22-14 DIN KP-FSD2 Pan-Term Terminals P22-RING P22-FORK BS22-BUTT 26-22 HSTT12-48-Q 12-6 DIN KP-FSD3 Recommended part number P18-RING P18-FORK BS18-BUTT 22-18 HSTT19-48-Q will cover both terminal P14-RING P14-FORK BS14-BUTT 16-14 HSTT19-48-Q 22-14 NON-INS KP-F1 and wire insulation P10-RING P10-FORK BS10-BUTT 12-10 HSTT25-48-Q 12-6 NON-INS KP-F2 www.panduit.com COLOR CODE COLOR CODE COLORRecommended Crimping Tool Selection Chart See product package or customer service for UL/CSA approved tooling/product combination Wire Wire Wire Strip Plier Tools Controlled Cycle Wire Strip Plier Tools Controlled Cycle Range Length Hand Tools Range Length Hand Tools Panduit Panduit Terminal Standard Terminal Standard Pan-Term Pan-Term Terminal Description Wire (+1/32-0) Terminal Description Wire (+1/32-0) Range (In.) Range (In.) Series Series (AWG) (AWG) BS Non-Insulated 26-22 1/4 X X JN Nylon JN224-318 24-16 7/16 X X X X X Butt Splices 22-18 9/32 X X X X X X Insulated JN218-216 22-16 7/16 X X X X 16-14 9/32 X X X X X X Wire JN418-212 18-12 1/2 X X X X 12-10 9/32 X X X X X X Joints JN314-412 14-12 5/8 X BSN Nylon Insulated 26-22 1/4 X X P-R Non-Insulated 26-22 3/16 X X X Butt Splices 22-18 9/32 X X X X X P-F Rings, Forks, 22-18 7/32 X X X X X X 16-14 9/32 X X X X X X X P-LF Locking Forks, 16-14 7/32 X X X X X X 12-10 9/32 X X X X X X P-SLF Short Locking Forks, 12-10 9/32 X X X X X X P-FF Flanged Forks BSV Vinyl Insulated 22-18 5/16 X X X X X X X Butt Splices 16-14 5/16 X X X X X X X X P-RHT6 High Temperature 22-18 9/32 X X X X X X 12-10 5/16 X X X X X X X Rings 16-14 9/32 X X X X X X 12-10 9/32 X X X X X X D Non-Insulated Sleeved 22-18 9/32 X X X X X X DR Barrel Disconnects 16-14 9/32 X X X X X X P-HDR Non-Insulated 16-12 9/32 X X X X X (Includes Right Angle Disc.) 12-10 9/32 X X X X X X Heavy Duty Non-Insulated Right Angle 22-18 9/32 X X X X P-P Non-Insulated, 22-18 9/32 X X X X X X D-MB Female Disc. and 16-14 9/32 X X X X Pin Terminals 16-14 9/32 X X X X X X Non-Insulated Male Butted 12-10 9/32 X X X X X X Seam Disconnect P-R Non-Insulated 8 3/8 D-M Non-Insulated Male 22-18 9/32 X X X X X X Large Ring Terminal 6 7/16 Use CT-1701 Crimping Tool Blade Adapters 16-14 9/32 X X X X X X 4 1/2 CT-2600 with CD-2600-P2 thru P8 dies 2 1/2 D-M Non-Insulated Male Disc. 12-10 9/32 X X X X X DNF Nylon Funnel Entry Barrel 22-18 9/32 X X X X PN-R Nylon and Nylon 26-22 3/16 X X X Insulated Disconnects 16-14 9/32 X X X X X X PN-F Funnel Entry, Forks, 22-18 7/32 X X X X (not .110/.111) PN-LF Locking Forks, 16-14 7/32 X X X X X PN-FF Flanged Forks 12-10 9/32 X X X X DNF-110 Nylon, Funnel Entry 22-18 7/32 X X X PNF-R (Includes Expanded DNF-111 Barrel Insulated Disc. 16-14 9/32 X X X PNF-F Insulation) .110/.111 Tab Size PNF-LF DNF-FI Nylon, Fully Insulated Disc. 12-10 3/8 X X X X X X PK-R KYNAR** Rings 22-18 7/32 X X X X X X DPF-FI Premium Nylon, Fully 12-10 3/8 X X X X X X 16-14 7/32 X X X X X X Ins. Disc. 12-10 9/32 X X X X DNF-FIB Nylon and Premium Grade 22-18 9/32 X X X PN-HDR Nylon Insulated Heavy 16-12 9/32 X X X PN-HDRX Duty & Nylon DNF-FIM Nylon, Fully Insulated, 16-14 9/32 X X X DNF-FIMB Funnel Entry, Male/Female 12-10 3/8 X X Expanded Insulated Heavy Duty Rings DPF-FIB Couplers DPF-FIM (not .110/.111) PN-RX Nylon Insulated 16-14 7/32 X X X X X DPF-FIMB Rings (Expanded 12-10 9/32 X X X X Insulation) DNF-FIB Nylon and Premium Grade 22-18 7/32 X X X DPF-FIB Nylon, Fully Insulated, PN-SLF Nylon Insulated 22-18 7/32 X X X Funnel Entry, Disconnect PNF-SLF Short Locking Forks 16-14 7/32 X X X X 12-10 9/32 X X X .110/.111 Tab Size PS Non-Insulated 22-18 5/16 X X X DNF-FIBX Nylon, Expanded Wire 22-18 9/32 X X X Parallel Splice 20-16 5/16 X X X Entry Fully Insulated 16-14 9/32 X X 14-12 7/16 X X X DNG-FB Supra Grip Nylon 22-18 1/4 X PSN Nylon Insulated 22-18 5/16 X X Fully Insulated Disconnect 16-14 1/4 X Parallel Splice 20-16 5/16 X X X X X DNF-M Nylon Insulated, Funnel 22-18 9/32 X X X X X 14-12 7/16 X X Entry, Barrel Insulated, 16-14 9/32 X X X X X PV-R Vinyl Insulated 26-22 3/16 X X X Male Disconnects 12-10 9/32 X X X X X X PV-F Rings and Forks 22-18 5/16 X X X X X X DNFR-FIB Nylon Butted Seam 22-18 11/32 X PV-FF (Includes Expanded 16-14 5/16 X X X X X X X Right Angle Disconnects 16-14 11/32 X PV-RX Insulation) 12-10 5/16 X X X X X X DNFR-B Nylon Pre-Insulated 22-18 9/32 X X PV-FX Right Angle Disconnects 16-14 9/32 X X PV-LF Vinyl Insulated 22-18 5/16 X X X X X DV-B Vinyl Insulated 22-18 1/4 X X X PV-LFX Locking Forks 16-14 5/16 X X X X X Butted Seam Disconnects 16-14 1/4 X X X (Includes Expanded 12-10 5/16 X X X X X DV Vinyl Barrel Insulated 12-10 9/32 X X X Insulation) Sleeved Disconnects PV-HDR Vinyl Insulated 16-12 5/16 X X X DV-M Vinyl Insulated 22-18 9/32 X X X X X X PV-HDRX Heavy Duty Rings Male Blade Adapters 16-14 9/32 X X X X X X X PV-P Vinyl Insulated 22-18 5/16 X X X X X DV-MB Vinyl Insulated Butted 22-18 9/32 X X X X Pin Terminals 16-14 5/16 X X X X X Seam Male Disconnects 16-14 9/32 X X X X X 12-10 5/16 X X X X X DV-M Vinyl Insulated Male Disc. 12-10 9/32 X X X PV-SLF Vinyl Insulated 22-18 5/16 X X X DV-P Vinyl Insulated 22-18 1/4 X X X X X Short Locking Forks 16-14 5/16 X X X X Piggyback Disconnects 16-14 1/4 X X X X X 12-10 5/16 X X DVF Vinyl Funnel Entry 22-18 9/32 X X PV-R Vinyl Insulated 8 3/8 Barrel Insulated Disconnect 16-14 9/32 X X PV-RX Large Ring 6 7/16 Use CT-720 Tool with CD-720PV8-2 Die Terminals 4 1/2 CT-2600 with CD-2600-PV2 thru PV8 dies J Non-Insulated J214-312 14-12 1/2 X X 2 1/2 Wire Joints J318-412 18-12 1/2 X X J216-410 16-10 3/4 X PH Heat Shrink 22-18 5/16 BSH Terminals 16-14 5/16 and Splices 12-10 5/16 Use CT-310 Crimping Tool DNH Heat Shrink 22-18 5/16 Disconnects 16-14 5/16 12-10 5/16 **KYNAR is a registered trademark of Atofina Chemicals, Inc. Pan-Term Terminal Crimping Tools HAND OPERATED Plier Type CT-1525 CT-300-1, CT-1700 (Used with S Series Tubular Terminals), Crimps Panduit 26 thru 22 AWG insulated terminals CT-1701, CT-1014, CT-1015, CT-400, CT-460, CT-310 for CT-100A Tool and splices 22 thru 10 AWG fully insulated disconnects heatshrink terminals Crimps 22 thru 10 insulated and non-insulated terminal and insulated parallel splices. Crimps specific Panduit 22 products. Cuts 4, 6, 8, and 10 screws. Battery Powered Crimping Tool CT-2500 thru 14 AWG barrel insulated disconnects. Crimps Panduit 22 10 AWG insulated and non-insulated CT-160 Tool CT-1550 /CT-1551 terminals, disconnects and splices. Includes tool, two Crimps 22 thru 10 insulated and non-insulated terminal Crimps most Panduit 22 thru 10 AWG nylon and vinyl batteries, a battery charger and carrying case. Crimp heads products. Cuts 3 U.S. and 3 meter bolt sizes. insulated terminals and splices. Crimps specific Panduit 22 not included. CT-200 Forged Steel Tool thru 10 AWG nylon and vinyl insulated disconnects. Battery powered Crimping Tool CT-2600 Crimps 22 thru 10 non-insulated terminal products. CT-1570 Crimps tin and nickel plated 8-2AWG high temperature large 2 CT-260 Forged Steel Tool Crimps most Panduit 22 thru 10 AWG and 0.5-6.0mm wire, non insulated, vinyl and Kynar insulated ring terminals. Crimps most Panduit 22 thru 10 insulated and non-insulated terminals and disconnects. Crimps specific Includes tool with crimp head, two battery cartridges 2 non-insulated terminal pockets. Panduit 22 thru 10 AWG and 0.5-6.0mm (CT-2500BC), battery charger (CT-2500CHR) and carrying non-insulated splices. case (CT-2500CASE). Crimp dies not included. HAND OPERATED Controlled Cycle Type SPECIALTY Controlled Cycle Type WOrldWide sUBsidiAries ANd sAles OFFiCes PANdUit CANAdA PANdUit eUrOPe ltd. PANdUit siNgAPOre Pte. ltd. PANdUit JAPAN PANdUit lAtiN AMeriCA PANdUit AUstrAliA PtY. ltd. Markham, Ontario london, UK republic of singapore tokyo, Japan guadalajara, Mexico ictoria, Australiav cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty 2014 Panduit Corp. All rights reserved. For more information Printed in the U.s.A. Visit us at www.panduit.com TMSG08--SA-ENG Contact Customer Service by email: cs panduit.com Replaces SA-TMSG05 or by phone: 800-777-3300 7/2014 CT-100A CT-160 CT-200 CT-260 CT-300-1 CT-400 CT-460 CT-1014 CT-1015 CT-1525 CT-1550/ CT-1551 CT-1570 CT-2500 CT-100A CT-160 CT-200 CT-260 CT-300-1 CT-400 CT-460 CT-1014 CT-1015 CT-1525 CT-1550/ CT-1551 CT-1570 CT-2500