Pan-Way LD Surface Raceway System
SPECIFICATION SHEET
LD Raceway
Raceway: LD3IW**-A
LD5IW**-A
LD10IW**-A
LD Raceway Fittings
specifications
Coupler: CF*IW-E
LD non-metallic series low voltage, one-piece hinged design,
Inside corner: ICFC*IW-X
single channel surface raceway shall include adhesive backing
Outside corner: OCFC*IW-X
and shall be made of impact resistant material with a smooth
Right angle: RAFC*IW-X
finish that shall not scratch, peel or corrode. The raceway shall
End cap: ECF*IW-X
include an assortment of bend radius and standard fittings that
Tee: TFC*IW-X
complement the offering to help route, protect and conceal low
Four-way cross: CRFC5IW-X
voltage data, voice and video cabling. LD raceway shall be
Drop ceiling/
available in three sizes and four standard colors that shall be
entrance end: DCF*IW-X
optimized with the Panduit Pan-Net communication system.
Right angle/
entrance end: RAEFXIW-X
LD5 to LD3
reducer: RF5X3IW-E
LD10 to LD5
technical information
reducer: RF10X5IW-X
Material: Rigid PVC
LD10 to LD3
reducer: RF10X3IW-X
Flammability: UL94V-0; FT4
LD5 fire box
Capacity: Single Channel
adapter: FBA5IW-X
LD10 fire box
Voltage Rating: 50V or less
adapter: FBA10IW-X
Operating and 0 to 50o C
LD Raceway Installation
Storage Temperature:
Installation tool: LDW*-V
LD Raceway Surface Mount
Outlet/Junction Boxes
Low Voltage:
Single gang,
key features and benefits
onepiece : JB1IW-A
Single gang,
1" bend radius Cables in the raceway will satisfy the minimum 1 bend radius
one-piece, deep: JB1DIW-A
control fittings: requirement, preventing the potential degradation of cable
Single gang,
performance; meets TIA/EIA standards
two-piece : JBX3510IW-A
One-piece hinged design: Cables can be laid into the raceway, speeding installation and
Single gang, two-piece,
preventing damage to cables
fast snap: JB1FSIW-A
In-wall box adapter: JBA-X
Adhesive backing: Full length adhesive strip allows easy tool free installation and
works well for temporary mounting
Power rated:
Available in different Single gang,
Accommodates varying cable types and capacities.
sizes & lengths: two-piece: JBP1IW
Available sizes - LD3, LD5,LD10 ;
Single gang,
Available lengths - 6,8,10 (2m length available in Europe only)
two-piece, deep: JBP1DIW
Non-metallic Lightweight, reducing installer fatigue and labor required to
Single gang,
construction: install the raceway; solid color throughout will not chip, peel,
two-piece, extension: JBP1EIW
rust or corrode; easy to cut with standard saws and saw blades,
Single gang, two-piece,
eliminating the need for special cutting devices
intermediate: JBP1IIW
Distinct colors: Available in four standard colors- IW,EI,IG,WH. AW available in Single gang, two-piece,
Europe only. Raceway is field paintable to match walls and snap on: JBP1FSIW
surrounding dcor Single gang,
two-piece, round: RJBX3510IW
Full selection of Wide variety of fittings and surface mount boxes available for
Double gang,
fittings and surface various LD raceway applications
two-piece: JBP2IW
mount boxes:
Double gang,
two-piece, deep: JBP2DIW
Double gang,
applications
two-piece, divided: JBP2SIW
Double gang,
Pan-Way LD Surface Raceways are baseboards or ceilings. This raceway is a
two-piece, snap on: JBP2FSIW
designed to provide easy and economical perfect solution for schools, hospitals, offices,
solutions for routing any low voltage cable homes or anywhere a small, secure, low
* Insert raceway size of 3, 5, or 10
along smooth and clean perimeter walls, profile raceway is needed.
** Insert raceway length of 6, 8, or 10
All parts listed in International White (IW) color.
To order other colors substitute Electrical Ivory
(EI), International Gray (IG), and White (WH).
www.panduit.com
Pan-Way LD Surface Raceway System
Wire Fill
FIber Optic
Electrical Cables Audio/Video Cable
14 12 10 Data Grade Cables
AWG AWG AWG 24 AWG/UTP CM
Fill
Raceway Type
THHN/T90 Cat 5e Plenum Cat. 6 Cat. 6A Cat. 6A (SD)
Area
RG6 2 Strand
and Configuration
2
(in )
0.111 0.130 0.164 DIA. = 0.193 DIA. = 0.24 DIA. = 0.30 DIA. = 0.24 DIA. = 0.275 DIA. = 0.175
FILL FILL FILL FILL FILL FILL FILL
MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX
(UL Temp Rise Test) 40% 60% 40% 60% 40% 60% 40% 60% 40% 60% 40% 60%
LD3 0.21 ** ** ** 2 4 1 2 1 1 1 2 1 2 3 5
LD5
0.38 ** ** ** 5 7 3 5 2 3 3 5 2 3 6 9
LD10 1.00 ** ** ** 13 20 8 13 5 8 8 13 6 10 16 24
LD Raceway
0.94
[23.9]
0.58
0.46
[14.8]
[11.7]
0.70
0.50
0.055
1.00
[17.8]
[12.7]
[1.4]
[25.4]
1.01
0.77
1.51
[25.8]
[19.6]
[38.4]
LD3 LD5 LD10
Fittings
ICFC
CF OCFC RAFC
ECF TFC CRFC5 DCF
RF
RAEFX FBA LDW
www.panduit.com