TM
specifications
Small form factor fiber optic modules shall be
compliant with the TIA FOCIS-6 Fiber Jack (FJ)
NETWORK CONNECTIVITY GROUP
interface specification. RJ-45 style module shall
be field terminable in one module space with no
SPEC SHEET
adapter. The module shall contain a factory
terminated pre-polished multimode fiber, requiring
no field polishing and no adhesive. The fibers
shall terminate in 2.5mm ferrules with a non-
optical disconnect and typical insertion loss of
0.35dB per connector.
MINI-COM OPTI-CRIMP FJ Fiber Optic Module Pre-polished Crimp
technical information OPTI-CRIMP Multimode Module
62.5/125m: FJJSMM5C**
Fiber compatibility: 62.5/125m and 50/125m multimode
50/125m: FJJSMM50C**
Fiber cable type: Tight buffered cable only (3.0mm jacketed and 900m) OPTI-PLUG Fiber Optic Connector
Multimode: FJEPGM5C**
Ferrule type: Ceramic (Zirconia) with a pre-polished fiber stub
Plug to Plug Coupler
Insertion loss: 0.35dB typical
Plug to plug coupler: FJGCCEI
(primarily used in testing)
Return loss: Greater than 20dB
Pre-polished Termination Tooling
key features and ...benefits
Pre-polished crimp
termination kit: FJMKIT
Pre-polished fiber stub Eliminates polishing steps, speeding installation
To upgrade from FJKITG, purchase FJQCVR
fiber cleaver tool
Mechanical crimp cable Consistently provides higher than industry standard cable
OPTI-CRIMP Multimode Module
retention retention; requires no adhesive, speeding installation
Pre-polished Replacement Ferrules
Small form factor Double the port density in one module space
62.5/125m: FJJSMFRL-X
connector at the outlet and in the telecommunications closet
50/125m: FJJSM50FRL-X
Proven 2.5mm ferrules Uses standard termination tools and procedures
Multimode Duplex Patch Cords
OPTI-PLUG connector
Robust design Protects fibers from mechanical and environmental stress
to OPTI-PLUG connector: F^D6P-6PM
OPTI-PLUG connector
Non-optical disconnect Maintains data transmission under tensile load
to OPTI-JACK module: F^D6P-6JM
OPTI-PLUG connector
RJ-45 form factor Familiar to end-users, snaps into all MINI-COM
to SC: F^D6P-3M
outlets and modular patch panels
OPTI-PLUG connector
to ST: F^D6P-2M
Field terminable module Allows flexibility to assemble special length patch
OPTI-PLUG connector
and connector cords on site
to FC: F^D6P-4M
OPTI-PLUG connector
Adapterless Fewer components to order and inventory
(Keyed W) to SC: F^D6PW-3M
OPTI-PLUG connector
Flush mount Unused ports do not protrude from the wall; can be
(Keyed W) to ST: F^D6PW-2M
used with shuttered faceplates
All key type (W, X, Y, Z) patch cords available
^Available in 62.5/125m (6) and 50/125m (5)
TIA standardization FOCIS-6 interface approved for the TIA, required for
Available in standard (1, 2, 3 and 10 meters)
TIA/EIA-568-B.3
and custom lengths
Keyed solution available Provides network security; limits access to highly sensitive,
**Substitute for
classified and segregated networks Colors: EI = Electric Ivory
BL = Black
BU = Blue
applications
IW = Off White
OR = Orange
Fiber-to-the-desk: The pre-polished Keyed network security: Four color-coded,
WH = White
mechanical crimp version ofOPTI-JACK (FJ) keyed configurations of the module and
Keyed Colors: WBL = Keyed W in Black
fiber optic module is the ultimate desktop fiber connector are available to provide mechanical
XRD = Keyed X in Red
YOR = Keyed Y in Orange
connector. The 2.5mm ferrule provides and visual differentiation to prevent
ZYL = Keyed Z in Yellow
robustness required for this demanding unintentional insertion into adjacent ports.
X = Bag of 10 ferrules and crimp sleeves
environment. The FJ interface module and Provides network security for military,
connector design is familiar to the end user government, financial and educational
and is polarized to prevent mismatch of applications. Universal keyed connector
installer tip
transmit and receive cables. Because there is available for testing purposes.
no adapter, unused ports remain flush with Telecommunications closet: The high port
the wall and away from damage. Shuttered density of the OPTI-CRIMP module reduces the
Reduces
faceplates can be used for further protection space requirements for fiber terminations in
installation time
of the unused ports. The modularity with the closet. This allows the end user to use
over standard
copper connectors allows for the complete less rack space and purchase fewer fiber
OPTI-JACK modules
data-communications solution to every enclosures. The multiple color options allow
workstation in one outlet. color coding of different networks or areas of by 70%.
the building for easier troubleshooting.
Visit our website at: www.panduit.com/ncg
MINI-COM OPTI-CRIMP FJ Fiber Optic Module Pre-polished Crimp
Standards Compliant Connector Performance
TIA ISO/IEC Performance
Test Procedure and
Description
TIA/EIA-568-B.3 Required Performance
455 874-1 After Test
100 cycles; -180 to 180 degrees; <0.2dB
1 -- Flex
max. insertion loss 0.75dB, min. return loss 20dB additional loss
8 drops from 1.8m;
<0.1dB
2 4.5.11 Impact
max. insertion loss 0.75dB, min. return loss 20dB
additional loss
4 days at 60C followed by post-conditioning FOTP-6;
<0.2dB
4 4.5.18 High Temperature
max. insertion loss 0.75dB, min. return loss 20dB
additional loss
4 days at 90-95% RH and 40C; <0.1dB
5 4.4.19 Humidity
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.4dB additional loss
11.24 lbs. at 0 degrees, 4.4 lbs. at 90 degrees; <0.2dB
6
4.5.4
Cable Retention
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.5dB additional loss
500 mate/unmate cycles; <0.1dB
21 4.5.32
Durability
max. insertion loss 0.75dB, min. return loss 20dB
additional loss
0.35dB
34 4.4.7 Insertion Loss
max. insertion loss 0.75dB, min. return loss 20dB
typical
10 cycles; 2.5 cw, 5 ccw, 2.5 cw; <0.1dB
36 4.5.5 Twist
max. insertion loss 0.75dB, min. return loss 20dB additional loss
107 --
Return Loss 20dB minimum return loss >20dB
7.4 lbs. at 0 degrees;
<0.1dB
185 4.5.6
Coupling Strength
max. insertion loss 0.75dB, min. return loss 20dB
additional loss
4 days at 0C; <0.1dB
188 4.5.17 Low Temperature
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.3dB additional loss
NOTE: Above tests performed at 850 and 1300nm on 3.0mm jacketed fiber cable.
.48
[12.1]
.53
[13.4]
.25
[6.4] A & B DESIGNATION
.25
2.17 [6.4] UNDER BOOT AFTER ASSEMBLY
[55.0]
.48
.26
[12.2]
.71
[6.6]
[18.0]
1.96 [49.7]
.26
[6.7]
Keyed W - Black Keyed X - Red Keyed Y - Orange Keyed Z - Yellow
Dimensions are in inches (Dimensions in parentheses are in millimeters)
Our products are warranted to be free from defects in material and workmanship at the time of sale but our This warranty is made in lieu of and excludes all other warranties, expressed or implied. THE IMPLIED
obligation under this warranty is limited to the replacement of any product proved to be defective within 6 WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY
months (for product) or 90 days (for tools) from the date of delivery. Tool warranty is void if Panduit tools EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or damage whether direct
are modified, altered or misused in any way. Use of Panduit tooling with any product other than the specified or consequential, arising out of the use of, or the inability to use, the product.
Panduit products for which the tool was designed, constitutes misuse. Before using, user shall determine The information contained in this literature is based on our experience to date and is believed to be reliable.
the suitability of the product for his intended use and user assumes all risk and liability whatsoever in It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not
connection therewith. guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein
are for reference purposes only. For specific dimensional requirements consult the factory. This publication is
WORLD HEADQUARTERS
not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This
PANDUIT CORP.
supersedes and voids all previous literature, etc.
Tinley Park, Illinois, USA
Phone: 888-506-5400, ext. 6914
For Pricing and Further Information
708-532-1800, ext. 6914
Fax: 708-460-2897 Contact your local authorized
NETWORK CONNECTIVITY GROUP Email: info@panduit.com
PANDUIT PAN-NET Distributor or Sales Office
Internet: www.panduit.com/ncg
PANDUIT CANADA EUROPEAN HEADQUARTERS ASIAN HEADQUARTERS PANDUIT CORP. PANDUIT MEXICO/LATIN AMERICA PANDUIT (AUST.) PTY. LTD.
Div. of PANDUIT CORP. PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. Japan Branch & CARIBBEAN Phone: (61) 3-9794 9020
Markham, Ontario London, UK Republic of Singapore Phone (81) (3) 3767-7011 Phone: (52) 3 666-2501
Phone: 905-475-6922 Phone: 44(0) 208-601-7200 Phone: (65) 379 6700
WW-NCSP1056A
PANDUIT Corp. 2001
Order SA-NC09SP01A
ALL RIGHTS RESERVED Printed in U.S.A.
WORLDWIDE SUBSIDIARIES AND SALES OFFICES