A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
12x4 FiberRunner System Spillouts
C.
Spill-overs allow safe transition from horizontal to Transition to channel, slotted channel, and corrugated
Fiber
vertical runs loom tubing Optic
Systems
2" (50.8mm) bend radius control Spill-over junction fittings can be retro-fitted to existing
horizontal runs
D.
Power
Std. Std. over
Ethernet
Couplers Pkg. Ctn.
Part Number Part Description Required Qty. Qty.
E.
12x4 Vertical Tee
Zone
FRVT12X4YL Attaches to 12x4 channel and/or fittings to create a (2 pcs.) 1
Cabling
90 vertical drop from a horizontal run. Hinged door FRBC12X4YL
included. Requires coupler to attach FRTR6X4YL (1 pc.)
or FRIDT6X4YL to vertical exit. Accepts optional FRBC6X4YL
snap-on cover FRHC12YL6 in conjunction
F.
FRVT12X4
with channel. Wireless
3-Sided BRC Trumpet Spillout for 6x4 Exit
FRTR6X4YL Used to limit the bend radius of the cable to 2" (1 pc.) 1 5
G.
(50.8mm) when exiting from 6x4 channel, 6x4 FRBC6X4YL
Outlets
horizontal tee fitting, or 6x4 exit on 12x4 vertical tee.
FRTR6X4
3-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
H.
FRIDT6X4YL Used to route cable into three separate pieces of (1 pc.) 1 5
Media
1.5" (38mm) diameter split corrugated tubing. Used FRBC6X4YL
Distribution
with FRVT12X4YL or any 6x4 fitting. Securely holds
corrugated split tubing to ensure system integrity
and easy access to add or remove cables. I.
Physical
FRIDT6X4
Infrastructure
4x4 Hinged Duct Vertical Cable Manager Kit
Management
FRHD4KTYL Provides secure, accessible route for cables spilling 1
out from vertical tee to rack mounted equipment. Kit
J.
includes 6' length of 4x4 capacity hinged duct, 6'
Overhead &
length of 4x4 hinged duct cover, one end cap for
Underfloor
4x4 hinged duct, three FZBA1.5X4 adjustable Z
Routing
brackets, an adapter fitting, six WR4-C wire
retainers and all required mounting hardware.
Attaches directly to 6x4 and 4x4 vertical tee exit K.
Surface
or FRLPR64 low profile reducer.
Raceway
FRHD4KT
4x4 Hinged Duct Bend Radius Control Trumpet
L.
TRC4HDBL Bend radius control trumpet for exiting at the 1 10
Cabinets,
sidewall of 4" wall heights of type H hinged cover
Racks &
wiring duct channels. Maintains 1" (25.4mm) bend
Cable
radius control. Black color only.
Management
Low Profile Reducer 6x4 to 4x4 for Vertical Tee
TRC4HDBL
M.
FRLPR64BL Assembled into the 12x4 vertical tee FRVT12X4YL. 1 5 Grounding &
Bonding
The FRLPR64BL allows for the transition to 4x4
Fiber-Duct Channel with minimal space required.
No tools required for assembly. Black color only.
N.
Spill-Over Junction with 2x2 Exit
Industrial
FRLPR64BL
FRSPJ2X2YL Assembles onto 4x4, 6x4, 12x4, or 24x4 (1 pc.) 1
FiberRunner Channel, spilling over the side into FBC2X2YL
a 2x2 vertical exit. Requires coupler to attach 2x2
O.
FiberRunner and fittings to the vertical exit.
Labeling &
Mounts directly to existing installation with no
Identification
alteration required. Mounting hardware provided
for secure attachment.
FRSPJ2X2 P.
Cover for Spill-Over Junction with 2x2 Exit for 12x4 Channel
Cable
Management
FRSPJC212YL Used to fully enclose 12x4 channel in conjunction 1 5
Accessories
with the spill-over junction FRSPJ2X2YL. Cover
snaps onto the channel base. Hinged feature allows
easy access to add or remove cables.
Q.
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black). Index
FRSPJC212
Table continues on next page
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog catalog back cover).
www.panduit.com J.17A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
12x4 FiberRunner System Spillouts (continued)
C.
Fiber
Optic Std. Std.
Systems
Couplers Pkg. Ctn.
Part Number Part Description Required Qty. Qty.
D.
3-Sided BRC Trumpet Spillout for 2x2 Exit
Power
over
FTR2X2YL Used to limit the bend radius of the cable to 2" (1 pc.) 1 5
Ethernet
(50.8mm) when exiting from a spill-over junction FBC2X2YL
with a 2x2 exit or from 2x2 Fiber-Duct Channel.
Securely holds split corrugated tubing to ensure
E.
system integrity and easy access to add or
Zone
remove cables.
Cabling
FTR2X2
1-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FIDT2X2YL Used to route cable into one piece of 1.5" (38mm) (1 pc.) 1 5
F.
diameter split corrugated tubing. Used with a FBC2X2YL
Wireless
spill-over junction with a 2x2 exit, 2x2 Fiber-Duct
Fittings, and the 2x2 FiberRunner Hinged Channel.
Securely holds split corrugated tubing to ensure
system integrity and easy access to add or
G.
remove cables.
Outlets
FIDT2X2
2x2 Hinged Duct Vertical Cable Manager Kit
FRHD2KTYL Provides secure, accessible route for cables spilling 1
H.
out from a vertical tee or spill-over junction to rack
Media
mounted equipment. Kit includes 6' length of 2x2
Distribution
FiberRunner Hinged Channel H2X2YL6, 6' length
of 2x2 snap-on hinged cover HC2YL6, four
I.
adjustable Z brackets FZBA1.5X4, one
Physical
FiberRunner 2x2 End Cap FHDEC2X2YL, six
Infrastructure
hinged duct 2" wire retainers WR2H-C and all
Management
required mounting hardware. Attaches to 2x2
vertical tee exit or spill-over junction with a 2x2
J. exit with a 2x2 QuikLock Coupler FBC2X2YL.
Overhead &
Also attaches directly to 4x4 or 6x4 vertical tee
Underfloor FRHD2KT
exits with low profile reducer FRLPR42BL.
Routing
2x2 FiberRunner Bend Radius Control Trumpet
K.
Surface
TRC2HDBL Bend radius control trumpet for exiting at the 1 10
Raceway
sidewall of 2" wall heights of type H hinged cover
wiring duct channels. Maintains 1" (25.4mm) bend
radius control. Black color only.
L.
Cabinets,
Racks & TRC2HDBL
Spill-Over Junction with 4x4 Exit
Cable
Management
FRSPJ4X4YL Assembles onto 4x4, 6x4, 12x4, or 24x4 (1 pc.) 1
FiberRunner Channel, spilling over the side into FRBC4X4YL
a 4x4 vertical exit. Requires coupler to attach 4x4
M.
FiberRunner Channel and fittings to the vertical
Grounding &
Bonding exit. Mounts directly to existing installation with no
alteration required. Mounting hardware provided for
secure attachment.
FRSPJ4X4
N.
Cover for Spill-Over Junction with 4x4 Exit for 12x4 Channel
Industrial
FRSPJC412YL Used to fully enclose 12x4 channel in conjunction 1 5
with the spill-over junction FRSPJ4X4YL. Cover
snaps onto the channel base. Hinged feature allows
O.
easy access to add or remove cables.
Labeling &
Identification
FRSPJC412
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
P.
Cable
Management
Accessories
Q.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.