A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner System Spillouts
C.
Spill-overs allow safe transition from horizontal Transition to channel, slotted channel, and corrugated
Fiber
to vertical runs loom tubing
Optic
Systems
2" (50.8mm) bend radius control Spill-over junction fittings can be retro-fitted to existing
horizontal runs
D.
Power
Std. Std.
over
Couplers Pkg. Ctn.
Ethernet
Part Number Part Description Required Qty. Qty.
6x4 QuikLock Vertical Tee
E.
Zone FRVT6X4YL Attaches to 6x4 channel and/or fittings to create (2 pcs.) 1 5
Cabling
90 vertical drop from a straight horizontal run. FRBC6X4YL
Hinged door included. Accepts FTR4X4YL,
FIDT4X4BL, S4X4YL6 or E4X4YL6 directly.
Accepts optional snap-on cover FRHC6YL6
F.
in conjunction with channel.
Wireless
FRVT6X4
3-Sided Vertical Tee Trumpet Spillout
FTR4X4YL Used to limit the bend radius of the cable to 1 5
G. 2" (50.8mm) when exiting from a 4x4 or 6x4
Outlets FiberRunner Vertical Tee and 4x4
Fiber-Duct Fittings.
2-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FTR4X4
H.
FIDT4X4BL Used to route cable into one or two pieces of 1.5" 1 5
Media
Distribution (38mm) diameter split corrugated tubing. Used with
FRVT6X4YL, FRVT4X4YL, or FVT4X4YL. Securely
holds corrugated split tubing to ensure system
I.
integrity and easy access to add or remove cables.
Physical
Black color only.
Infrastructure
Management
FIDT4X4BL
4x4 Hinged Duct Vertical Cable Manager Kit
FRHD4KTYL Provides secure, accessible route for cables spilling 1
J.
out from vertical tee to rack mounted equipment.
Overhead &
Kit includes 6' length of 4x4 capacity hinged duct,
Underfloor
Routing 6' length of 4x4 hinged duct cover, one end cap for
4x4 hinged duct, three FZBA1.5X4 adjustable Z
brackets, an adapter fitting, six WR4-C wire
K.
retainers and all required mounting hardware.
Surface
Attaches directly to 6x4 and 4x4 vertical tee exit
Raceway
or FRLPR64 low profile reducer.
L.
FRHD4KT
4x4 Hinged Duct Bend Radius Control Trumpet
Cabinets,
Racks &
TRC4HDBL Bend radius control trumpet for exiting at the 1 10
Cable
sidewall of 4" wall heights of type H hinged cover
Management
wiring duct channels. Maintains 1" (25.4mm) bend
radius control. Black color only.
M.
Grounding &
TRC4HDBL
Low Profile Reducer 4x4 to 2x2 for Vertical Tee
Bonding
FRLPR42BL Assembled into the 6x4 vertical tee FRVT6X4YL or 1 5
4x4 vertical tee FRVT4X4YL with an audible snap,
the FRLPR42BL allows for the transition to 2x2
N.
FiberRunner or 2x2 Fiber-Duct Channel with
Industrial
minimal space required. No tools required for
assembly. Black color only.
FRLPR42BL
Spill-Over Junction with 2x2 Exit
O.
Labeling &
FRSPJ2X2YL Assembles onto 4x4, 6x4, 12x4, or 24x4 (1 pc.) 1
Identification
FiberRunner Channel, spilling over the side into FBC2X2YL
a 2x2 vertical exit. Requires coupler to attach 2x2
FiberRunner and fittings to the vertical exit.
P.
Mounts directly to existing installation with no
Cable
alteration required. Mounting hardware provided
Management
for secure attachment.
Accessories FRSPJ2X2
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
Q.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner System Spillouts (continued)
C.
Fiber
Std. Std. Optic
Systems
Couplers Pkg. Ctn.
Part Number Part Description Required Qty. Qty.
D.
Cover for Spill-Over Junction with 2x2 Exit for 6x4 Channel Power
over
FRSPJC26YL Used to fully enclose 6x4 channel in conjunction 1 5
Ethernet
with the spill-over junction FRSPJ2X2YL. Cover
snaps onto the channel base. Hinged feature allows
easy access to add or remove cables.
E.
Zone
FRSPJC26
3-Sided BRC Trumpet Spillout for 2x2 Exit Cabling
FTR2X2YL Used to limit the bend radius of the cable to 2" (1 pc.) 1 5
(50.8mm) when exiting from a spill-over junction FBC2X2YL
with a 2x2 exit or from 2x2 Fiber-Duct Channel.
F.
Securely holds split corrugated tubing to ensure
Wireless
system integrity and easy access to add or
remove cables.
FTR2X2
1-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
G.
Outlets
FIDT2X2YL Used to route cable into one piece of 1.5" (38mm) (1 pc.) 1 5
diameter split corrugated tubing. Used with a FBC2X2YL
spill-over junction with a 2x2 exit, 2x2 Fiber-Duct
Fittings, and the 2x2 FiberRunner Hinged
H.
Channel. Securely holds split corrugated tubing
Media
to ensure system integrity and easy access to
Distribution
add or remove cables.
FIDT2X2
I.
2x2 Hinged Duct Vertical Cable Manager Kit
Physical
FRHD2KTYL Provides secure, accessible route for cables spilling 1
Infrastructure
out from a vertical tee or spill-over junction to rack
Management
mounted equipment. Kit includes 6' length of 2x2
FiberRunner Hinged Channel H2X2YL6, 6' length
J.
of 2x2 snap-on hinged cover HC2YL6, four
Overhead &
adjustable Z brackets FZBA1.5X4, one
Underfloor
FiberRunner 2x2 End Cap FHDEC2X2YL,
Routing
six hinged duct 2" wire retainers WR2H-C and
all required mounting hardware. Attaches to 2x2
vertical tee exit or spill-over junction with a 2x2
K.
exit with a 2x2 QuikLock Coupler FBC2X2YL.
Surface
Also attaches directly to 4x4 or 6x4 vertical tee Raceway
FRHD2KT
exits with low profile reducer FRLPR42BL.
L.
Cabinets,
Racks &
2x2 FiberRunner Bend Radius Control Trumpet
Cable
TRC2HDBL Bend radius control trumpet for exiting at the 1 10
Management
sidewall of 2" wall heights of type H hinged cover
wiring duct channels. Maintains 1" (25.4mm) bend
M.
radius control. Black color only.
TRC2HDBL
Grounding &
Bonding
Spill-Over Junction with 4x4 Exit
FRSPJ4X4YL Assembles onto 4x4, 6x4, 12x4, or 24x4 (1 pc.) 1
FiberRunner Channel, spilling over the side into FRBC4X4YL
N.
a 4x4 vertical exit. Requires coupler to attach 4x4
Industrial
FiberRunner Channel and fittings to the vertical
exit. Mounts directly to existing installation with no
alteration required. Mounting hardware provided
for secure attachment.
O.
FRSPJ4X4
Labeling &
Identification
Cover for Spill-Over Junction with 4x4 Exit for 6x4 Channel
FRSPJC46YL Used to fully enclose 6x4 channel in conjunction 1 5
with the spill-over junction FRSPJ4X4YL. Cover
P.
snaps onto the channel base. Hinged feature
Cable
allows easy access to add or remove cables.
Management
FRSPJC46
Accessories
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
Q.
Index
Table continues on next page
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog back cover).
www.panduit.com J.29