IndustrialNet M12 X-Code Field Terminable Plug SPECIFICATION SHEET IndustrialNet M12 X-Code Field Terminable Plug Field terminable specifications plug: ISPS6A88MFA Industrial M12 X-Code field terminable plug shall be applicable for use in IndustrialNet Category 6 S/FTP manufacturing as well as other industrial environments. The M12 X-Code plug Copper Cable Flame Retardant, shall meet or exceed the requirements of ANSI/TIA-568-C.2 Category 6A and Halogen-Free ISO 11801 Class E and with ODVA Ethernet/IP , PROFINET and CC-Link. A 4-pair, The plug shall be constructed of a zinc die cast housing with 360 shielding. color Yellow: ISX6004AYL-LED To meet more demanding industrial applications, the plug shall incorporate 4-pair, an ingress protection rating of IP65/IP67 and offer an extended temperature color Red: ISX6004ARD-LED range. The plug shall be easily field attachable without any special tools and IndustrialNet Category 5e SF/UTP, shall be capable of termination to a 4-pair stranded or solid twisted pair copper Copper Cable TPE Jacket cable - up to ten re-terminations with the same gauge cable. CM 4-pair color Teal: ISFCH5C04ATL-XG technical information IndustrialNet Category 6A/6/5e RJ45 Category 6A/Class Exceeds channel and component requirements of ANSI/TIA-568-C.2 Category 6A Field Terminable Plug and ISO11801 Class E standards at swept frequencies 1 to 500 MHz E channel and A A Field terminable component plug: ISPS688FA performance: IndustrialNet Category 5e Shielded Electrical/mechanical Shall meet ODVA Ethernet/IP , PROFINET and CC-Link performance 600 V-Rated Patch Cords requirements performance: CM/CMX color Teal: ISTPHCH1MTL* IEC compliance: Plug meets IEC 61076-2-109, IEC 60532-4, and IEC 60529 specifications IndustrialNet M12 X-Code to RJ45 Environmental Industrial connector protects and seals connections against dust and water Panel Mount Adapter immersion to IP65/IP67 per ANSI/IEC 60529-2004 vibration, temperature and protection: Panel mount chemical resistant shielded version further enhances electromagnetic performance adapter: ICAM12XRJS UL compliance: Compliant to UL 1863 IndustrialNet DIN Rail Mount Patch Panel RoHS compliancy Compliant status: 8-port: CDPP8RG Mini-Com DIN Rail Mount Adapter PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications 1-port: CADIN1IG** Temperature rating: -25C to 85C (-13F to 185F) operating and storage Wiring Scheme: 8-position *For other lengths, change the length designation (1M) of the part number to the Conductor Stranded AWG 26/7-22/7 desired length (0.3M, 0.6M, 2M, 3M, 5M, Solid AWG 26/1-22/1 termination range: 10M, 15M or 20M). Contact Panduit Customer Service for other color options. Conductor Insulation 1.1 2.1mm (0.043 0.079 inch) termination range: **For standard colors other than International Gray, replace IG in part number with Cable jacket 5.5 9mm (0.217 0.354 inch) BL (Black), EI (Electric Ivory), IW (Off White), diameter range: or WH (White). Packaging: 1 unit per polyethylene bag, 25 units per carton EtherNet/IP is a trademark of ODVA. key features and benefits Zinc die cast housing Ensures secure data transmission in high noise (EMI/RFI) environments for with 360 shielding: optimal performance Field attachable: Can be terminated in seconds without any special tools and is re-terminable up to 10 times with the same gauge cable IP/NEMA/UL rated Withstands light wash down and temporary submerged conditions without connection: loss of performance for reliability in harsh factory environments Extended temperature Provides durable connection in extreme conditions for increased system range: reliability applications IndustrialNet M12 X-Code field terminable plug Constructed of a robust die cast housing and fully provides an ideal solution to support Industrial shielded, the plug provides reliable operation in high Ethernet from the Local Area Network (LAN) based noise (EMI/RFI) environments. The plug meets the support offices to the processing devices on the plant ingress protection rating of IP65/IP67 for use where floor. A key component to the overall industrial Ethernet light wash downs are common/required in the food (up to 10 Gigabit) application, the plug is the interface and beverage industry. The plug offers an extended that protects the integrity of the Ethernet data transfer temperature range -25C to 85C (-13F to 185F) from the switch or PLC out to the devices or up to the for use in more demanding applications such as horizontal plant backbone. manufacturing facilities where temperature extremes are the norm. www.panduit.com/ia IndustrialNet M12 X-Code Field Terminable Plug 2.32 0.40 58.9 0.41 10.2 10.5 0.59 14.9 0.78 19.7 Pin 1 M12 Thread Contact Cable End End Dimensions are in inches. Dimensions in brackets are metric. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2018 Panduit Corp. Visit us at www.panduit.com/ia ALL RIGHTS RESERVED. iai panduit.com COSP402--SA-ENG 5/2018