ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, One-Hole, Standard Barrel with Window Lug B1. For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors Cable Ties Type LCAX Can be used with code conductor and flex conductor class: G, H, I, Inspection window to visually assure full conductor insertion B2. K, M and Diesel Locomotive Tin-plated to inhibit corrosion Cable Generously beveled wire entry prevents bent back strands when UL Listed and CSA Certified to 35 KV** and temperature rated to Accessories inserting conductor into barrel 90C when crimped with Panduit and specified competitor Color-coded barrels marked with Panduit and specified competitor crimping tools and dies B3. die index numbers for proper crimp die selection American Bureau of Shipping approved Stainless Steel Ties C1. W Wiring Duct L C2. Surface B Raceway INSPECTION WINDOW T C3. Abrasion Protection Figure Dimensions Stud Burndy T&B Flex Conductor Size (In.) Code Hole Panduit Panduit Die Die Wire Strip Std. Class Diesel Conductor Size Color Die Index Index Index Length Pkg. C4. Part Number G, H, I, K, M Locomotive Size (In.) W B T L Code No. No. No. (In.) Qty. Cable Management LCAX8-10-L 10 0.41 0.42 0.08 1.11 Red P21 49 21 1/2 50 LCAX8-14-L 1/4 0.48 0.42 0.07 1.20 Red P21 49 21 1/2 50 8 AWG 8 AWG 8 AWG LCAX8-56-L 5/16 0.56 0.42 0.05 1.32 Red P21 49 21 1/2 50 D1. LCAX8-38-L 3/8 0.60 0.42 0.05 1.42 Red P21 49 21 1/2 50 Terminals LCAX6-10-L 10 0.45 0.48 0.09 1.19 Blue P24 7 24 9/16 50 LCAX6-14-L 1/4 0.48 0.48 0.08 1.28 Blue P24 7 24 9/16 50 6 AWG 6 AWG 6 AWG LCAX6-56-L 5/16 0.56 0.48 0.07 1.40 Blue P24 7 24 9/16 50 D2. Power LCAX6-38-L 3/8 0.62 0.48 0.06 1.50 Blue P24 7 24 9/16 50 Connectors LCAX4-10-L 10 0.55 0.53 0.09 1.26 Gray P29 8 29 5/8 50 LCAX4-14-L 1/4 0.55 0.53 0.09 1.35 Gray P29 8 29 5/8 50 5, 4, 3 4 AWG 4 AWG D3. LCAX4-56-L AWG 5/16 0.55 0.53 0.09 1.47 Gray P29 8 29 5/8 50 Grounding LCAX4-38-L 3/8 0.62 0.53 0.07 1.57 Gray P29 8 29 5/8 50 Connectors LCAX2-10-E* 10 0.70 0.59 0.11 1.40 Brown P33 10 33 11/16 20 LCAX2-14-E* 1/4 0.70 0.59 0.11 1.50 Brown P33 10 33 11/16 20 E1. LCAX2-56-E* 5/16 0.70 0.59 0.11 1.63 Brown P33 10 33 11/16 20 2 AWG 2 AWG 2 AWG Labeling LCAX2-38-E* 3/8 0.70 0.59 0.11 1.70 Brown P33 10 33 11/16 20 Systems LCAX2-12-E* 1/2 0.75 0.59 0.09 1.94 Brown P33 10 33 11/16 20 LCAX1-10-X 10 0.76 0.66 0.12 1.50 Green P37 11 37 3/4 10 E2. LCAX1-14-X 1/4 0.76 0.66 0.12 1.67 Green P37 11 37 3/4 10 Labels LCAX1-56-X 5/16 0.76 0.66 0.12 1.72 Green P37 11 37 3/4 10 1 AWG 1 AWG 1 AWG LCAX1-38-X 3/8 0.76 0.66 0.12 1.80 Green P37 11 37 3/4 10 E3. LCAX1-12-X 1/2 0.80 0.66 0.12 2.03 Green P37 11 37 3/4 10 Pre-Printed See pages D3.70 D3.73 for tool and die information. & Write-On Markers *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, One-Hole, Standard Barrel with Window Lug (continued) B1. Cable Ties Figure Dimensions Stud Burndy T&B Flex Conductor Size (In.) Code Hole Panduit Panduit Die Die Wire Strip Std. Class Diesel Conductor Size Color Die Index Index Index Length Pkg. B2. Part Number G, H, I, K, M Locomotive Size (In.) W B T L Code No. No. No. (In.) Qty. Cable Accessories LCAX1/0-14-X 1/4 0.85 0.72 0.13 1.82 Pink P42 12 42 3/4 10 LCAX1/0-56-X 5/16 0.85 0.72 0.13 1.82 Pink P42 12 42 3/4 10 LCAX1/0-38-X 3/8 0.85 0.72 0.13 1.89 Pink P42 12 42 3/4 10 1/0 AWG 1/0 AWG 1/0 AWG B3. LCAX1/0-12-X Stainless 1/2 0.85 0.72 0.13 2.14 Pink P42 12 42 3/4 10 Steel Ties LCAX1/0-58-X 5/8 0.96 0.72 0.11 2.38 Pink P42 12 42 3/4 10 LCAX2/0-10-X 10 0.96 0.83 0.13 1.72 Black P45 13 45 7/8 10 LCAX2/0-14-X C1. 1/4 0.96 0.83 0.13 1.97 Black P45 13 45 7/8 10 Wiring LCAX2/0-56-X 5/16 0.96 0.83 0.13 1.97 Black P45 13 45 7/8 10 Duct 2/0 AWG 2/0 AWG 2/0 AWG LCAX2/0-38-X 3/8 0.96 0.83 0.13 2.03 Black P45 13 45 7/8 10 LCAX2/0-12-X 1/2 0.96 0.83 0.13 2.28 Black P45 13 45 7/8 10 C2. LCAX2/0-58-X 5/8 0.96 0.83 0.13 2.52 Black P45 13 45 7/8 10 Surface LCAX3/0-10-X 10 1.06 0.91 0.14 1.84 Orange P50 14 50 1 10 Raceway LCAX3/0-14-X 1/4 1.06 0.91 0.14 2.08 Orange P50 14 50 1 10 LCAX3/0-56-X 5/16 1.06 0.91 0.14 2.10 Orange P50 14 50 1 10 C3. 3/0 AWG 3/0 AWG 3/0 AWG LCAX3/0-38-X 3/8 1.06 0.91 0.14 2.17 Orange P50 14 50 1 10 Abrasion LCAX3/0-12-X 1/2 1.06 0.91 0.14 2.40 Orange P50 14 50 1 10 Protection LCAX3/0-58-X 5/8 1.06 0.91 0.14 2.64 Orange P50 14 50 1 10 LCAX4/0-14-X 1/4 1.19 1.03 0.16 2.30 Purple P54 15 54 1 1/16 10 C4. LCAX4/0-56-X Cable 5/16 1.19 1.03 0.16 2.53 Purple P54 15 54 1 1/16 10 Management LCAX4/0-38-X 3/8 1.19 1.03 0.16 2.53 Purple P54 15 54 1 1/16 10 4/0 AWG 4/0 AWG 4/0 AWG LCAX4/0-12-X 1/2 1.19 1.03 0.16 2.64 Purple P54 15 54 1 1/16 10 LCAX4/0-58-X 5/8 1.19 1.03 0.16 2.85 Purple P54 15 54 1 1/16 10 D1. LCAX4/0-34-X 3/4 1.19 1.03 0.16 3.04 Purple P54 15 54 1 1/16 10 Terminals LCAX250-14-X 1/4 1.281.030.172.34 Yellow P62 16 62 1 1/16 10 LCAX250-56-X 5/16 1.28 1.03 0.17 2.57 Yellow P62 16 62 1 1/16 10 LCAX250-38-X D2. 3/8 1.28 1.03 0.17 2.57 Yellow P62 16 62 1 1/16 10 250 kcmil 262.6 kcmil Power LCAX250-12-X 1/2 1.28 1.03 0.17 2.68 Yellow P62 16 62 1 1/16 10 Connectors LCAX250-58-X 5/8 1.28 1.03 0.17 2.89 Yellow P62 16 62 1 1/16 10 LCAX250-34-X 3/4 1.281.030.173.08 Yellow P62 16 62 1 1/16 10 D3. LCAX300-38-6 3/8 1.39 1.19 0.18 2.91 Red P71 18 71H 1 1/4 6 Grounding LCAX300-12-6 1/2 1.39 1.19 0.18 2.91 Red P71 18 71H 1 1/4 6 300 kcmil 313.1 kcmil Connectors LCAX300-58-6 5/8 1.39 1.19 0.18 3.12 Red P71 18 71H 1 1/4 6 LCAX350-56-6 5/16 1.54 1.29 0.22 2.93 Blue P76 19 76H 1 3/8 6 E1. LCAX350-38-6 3/8 1.54 1.29 0.22 2.93 Blue P76 19 76H 1 3/8 6 Labeling 350 kcmil 373.7 kcmil LCAX350-12-6 Systems 1/2 1.54 1.29 0.22 3.09 Blue P76 19 76H 1 3/8 6 LCAX350-58-6 5/8 1.54 1.29 0.22 3.30 Blue P76 19 76H 1 3/8 6 LCAX450-12-6 1/2 1.70 1.40 0.26 3.60 Brown P87 20 87H 1 7/16 6 450 kcmil 444.4 kcmil E2. LCAX450-58-6 5/8 1.70 1.40 0.26 3.73 Brown P87 20 87H 1 7/16 6 Labels LCAX500-56-6 5/16 1.89 1.48 0.26 3.27 Pink P99 L99 99H 1 9/16 6 LCAX500-38-6 3/8 1.89 1.48 0.26 3.27 Pink P99 L99 99H 1 9/16 6 500 kcmil 535.3 kcmil E3. LCAX500-12-6 1/2 1.89 1.48 0.26 3.64 Pink P99 L99 99H 1 9/16 6 Pre-Printed LCAX500-58-6 5/8 1.89 1.48 0.26 4.20 Pink P99 L99 99H 1 9/16 6 & Write-On LCAX650-56-6 Markers 5/16 1.95 1.45 0.30 3.27 Black P106 24 106H 1 1/2 6 LCAX650-38-6 3/8 1.95 1.45 0.30 3.27 Black P106 24 106H 1 1/2 6 646.4 kcmil LCAX650-12-6 E4. 1/2 1.95 1.45 0.30 3.64 Black P106 24 106H 1 1/2 6 Permanent LCAX650-58-6 5/8 1.95 1.45 0.30 4.20 Black P106 24 106H 1 1/2 6 Identification LCAX750-12-3 1/2 2.17 1.66 0.32 3.94 Yellow P115 L115 115H 1 3/4 3 777.7 kcmil LCAX750-58-3 E5. 5/8 2.17 1.66 0.32 4.59 Yellow P115 L115 115H 1 3/4 3 Lockout/ See pages D3.70 D3.73 for tool and die information. Tagout *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. & Safety **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. Solutions F. Index For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)