ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, One-Hole, Standard Barrel with Window Lug, 90 Angle B1. For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors Cable Ties Type LCAX-F Can be used with code conductor and flex conductor class: G, H, I, Inspection window to visually assure full conductor insertion B2. K, M and Diesel Locomotive Tin-plated to inhibit corrosion Cable Generously beveled wire entry prevents bent back strands when UL Listed and CSA Certified to 35 KV** and temperature rated to Accessories inserting conductor into barrel 90C when crimped with Panduit and specified competitor crimping Color-coded barrels marked with Panduit and specified competitor tools and dies B3. die index numbers for proper crimp die selection American Bureau of Shipping approved Stainless Steel Ties INSPECTION W WINDOW C1. Wiring Duct T C2. 90 Surface Raceway B L C3. Abrasion Protection Figure Dimensions Burndy T&B Wire Flex Conductor Size (In.) Code Panduit Panduit Die Die Strip Std. Class Diesel Conductor Stud Hole Color Die Index Index Index Length Pkg. C4. Part Number G, H, I, K, M Locomotive Size Size (In.) W B T L Code No. No. No. (In.) Qty. Cable LCAX8-10F-L 10 0.41 0.42 0.08 0.90 Red P21 49 21 1/2 50 Management LCAX8-14F-L 1/4 0.48 0.42 0.07 0.99 Red P21 49 21 1/2 50 8 AWG 8 AWG 8 AWG LCAX8-56F-L 5/16 0.56 0.42 0.05 1.11 Red P21 49 21 1/2 50 LCAX8-38F-L 3/8 0.60 0.42 0.05 1.21 Red P21 49 21 1/2 50 D1. Terminals LCAX6-10F-L 10 0.45 0.48 0.09 0.99 Blue P24 7 24 9/16 50 LCAX6-14F-L 1/4 0.48 0.48 0.08 1.03 Blue P24 7 24 9/16 50 6 AWG 6 AWG 6 AWG LCAX6-56F-L 5/16 0.56 0.48 0.07 1.15 Blue P24 7 24 9/16 50 D2. LCAX6-38F-L 3/8 0.62 0.48 0.06 1.25 Blue P24 7 24 9/16 50 Power LCAX4-10F-L 10 0.55 0.53 0.09 1.03 Gray P29 8 29 5/8 50 Connectors LCAX4-14F-L 1/4 0.55 0.53 0.09 1.12 Gray P29 8 29 5/8 50 5, 4, 3 4 AWG 4 AWG LCAX4-56F-L AWG 5/16 0.55 0.53 0.09 1.24 Gray P29 8 29 5/8 50 D3. LCAX4-38F-L 3/8 0.62 0.53 0.07 1.34 Gray P29 8 29 5/8 50 Grounding Connectors LCAX2-10F-E* 10 0.70 0.59 0.11 1.21 Brown P33 10 33 11/16 20 LCAX2-14F-E* 1/4 0.70 0.59 0.11 1.31 Brown P33 10 33 11/16 20 LCAX2-56F-E* 5/16 0.70 0.59 0.11 1.44 Brown P33 10 33 11/16 20 2 AWG 2 AWG 2 AWG E1. Labeling LCAX2-38F-E* 3/8 0.70 0.59 0.11 1.51 Brown P33 10 33 11/16 20 Systems LCAX2-12F-E* 1/2 0.75 0.59 0.09 1.75 Brown P33 10 33 11/16 20 LCAX1-10F-X 10 0.76 0.66 0.12 1.28 Green P37 11 37 3/4 10 LCAX1-14F-X 1/4 0.76 0.66 0.12 1.45 Green P37 11 37 3/4 10 E2. LCAX1-56F-X 5/16 0.76 0.66 0.12 1.51 Green P37 11 37 3/4 10 Labels 1 AWG 1 AWG 1 AWG LCAX1-38F-X 3/8 0.76 0.66 0.12 1.58 Green P37 11 37 3/4 10 LCAX1-12F-X 1/2 0.80 0.66 0.12 1.82 Green P37 11 37 3/4 10 E3. LCAX1/0-14F-X 1/4 0.85 0.72 0.13 1.59 Pink P42 12 42 3/4 10 Pre-Printed & Write-On LCAX1/0-56F-X 5/16 0.85 0.72 0.13 1.59 Pink P42 12 42 3/4 10 1/0 AWG 1/0 AWG 1/0 AWG Markers LCAX1/0-38F-X 3/8 0.85 0.72 0.13 1.66 Pink P42 12 42 3/4 10 LCAX1/0-12F-X 1/2 0.85 0.72 0.13 1.91 Pink P42 12 42 3/4 10 E4. See pages D3.70 D3.73 for tool and die information. Permanent *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. Identification **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. E5. Lockout/ Tagout & Safety Solutions F. Index Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, One-Hole, Standard Barrel with Window Lug, 90 Angle (continued) B1. Cable Ties Figure Dimensions Burndy T&B Wire Flex Conductor Size (In.) Code Panduit Panduit Die Die Strip Std. Class Diesel Conductor Stud Hole Color Die Index Index Index Length Pkg. B2. Part Number G, H, I, K, M Locomotive Size Size (In.) W B T L Code No. No. No. (In.) Qty. Cable LCAX2/0-10F-X 10 0.96 0.83 0.13 1.42 Black P45 13 45 7/8 10 Accessories LCAX2/0-14F-X 1/4 0.96 0.83 0.13 1.67 Black P45 13 45 7/8 10 LCAX2/0-56F-X 5/16 0.96 0.83 0.13 1.67 Black P45 13 45 7/8 10 B3. 2/0 AWG 2/0 AWG 2/0 AWG LCAX2/0-38F-X 3/8 0.96 0.83 0.13 1.73 Black P45 13 45 7/8 10 Stainless Steel Ties LCAX2/0-12F-X 1/2 0.96 0.83 0.13 1.98 Black P45 13 45 7/8 10 LCAX2/0-58F-X 5/8 0.96 0.83 0.13 2.27 Black P45 13 45 7/8 10 LCAX3/0-10F-X 10 1.06 0.91 0.14 1.51 Orange P50 14 50 1 10 C1. Wiring LCAX3/0-14F-X 1/4 1.06 0.91 0.14 1.75 Orange P50 14 50 1 10 Duct LCAX3/0-56F-X 5/16 1.06 0.91 0.14 1.77 Orange P50 14 50 1 10 3/0 AWG 3/0 AWG 3/0 AWG LCAX3/0-38F-X 3/8 1.06 0.91 0.14 1.84 Orange P50 14 50 1 10 LCAX3/0-12F-X 1/2 1.06 0.91 0.14 2.07 Orange P50 14 50 1 10 C2. Surface LCAX4/0-14F-X 1/4 1.19 1.03 0.16 1.84 Purple P54 15 54 1 1/16 10 Raceway LCAX4/0-56F-X 5/16 1.19 1.03 0.16 2.07 Purple P54 15 54 1 1/16 10 LCAX4/0-38F-X 3/8 1.19 1.03 0.16 2.07 Purple P54 15 54 1 1/16 10 4/0 AWG 4/0 AWG 4/0 AWG C3. LCAX4/0-12F-X 1/2 1.19 1.03 0.16 2.18 Purple P54 15 54 1 1/16 10 Abrasion LCAX4/0-58F-X 5/8 1.19 1.03 0.16 2.39 Purple P54 15 54 1 1/16 10 Protection LCAX4/0-34F-X 3/4 1.19 1.03 0.16 2.58 Purple P54 15 54 1 1/16 10 LCAX250-14F-X 1/4 1.28 1.03 0.17 1.90 Yellow P62 16 62 1 1/16 10 C4. LCAX250-56F-X 5/16 1.28 1.03 0.17 2.13 Yellow P62 16 62 1 1/16 10 Cable LCAX250-38F-X 3/8 1.28 1.03 0.17 2.13 Yellow P62 16 62 1 1/16 10 Management 250 kcmil 262.6 kcmil LCAX250-12F-X 1/2 1.28 1.03 0.17 2.24 Yellow P62 16 62 1 1/16 10 LCAX250-58F-X 5/8 1.28 1.03 0.17 2.45 Yellow P62 16 62 1 1/16 10 D1. LCAX250-34F-X 3/4 1.28 1.03 0.17 2.64 Yellow P62 16 62 1 1/16 10 Terminals LCAX300-38F-6 3/8 1.39 1.19 0.18 2.37 Red P71 18 71H 1 1/4 6 LCAX300-12F-6 1/2 1.39 1.19 0.18 2.37 Red P71 18 71H 1 1/4 6 300 kcmil 313.1 kcmil LCAX300-58F-6 5/8 1.39 1.19 0.18 2.58 Red P71 18 71H 1 1/4 6 D2. LCAX350-56F-6 5/16 1.54 1.29 0.22 2.32 Blue P76 19 76H 1 3/8 6 Power Connectors LCAX350-38F-6 3/8 1.54 1.29 0.22 2.32 Blue P76 19 76H 1 3/8 6 350 kcmil 373.7 kcmil LCAX350-12F-6 1/2 1.54 1.29 0.22 2.48 Blue P76 19 76H 1 3/8 6 LCAX350-58F-6 5/8 1.54 1.29 0.22 2.69 Blue P76 19 76H 1 3/8 6 D3. Grounding LCAX450-12F-6 1/2 1.70 1.40 0.26 2.95 Brown P87 20 87H 1 7/16 6 Connectors 450 kcmil 444.4 kcmil LCAX450-58F-6 5/8 1.70 1.40 0.26 3.08 Brown P87 20 87H 1 7/16 6 LCAX500-56F-6 5/16 1.89 1.48 0.26 2.44 Pink P99 L99 99H 1 9/16 6 E1. LCAX500-38F-6 3/8 1.89 1.48 0.26 2.69 Pink P99 L99 99H 1 9/16 6 Labeling 500 kcmil 535.3 kcmil LCAX500-12F-6 1/2 1.89 1.48 0.26 2.81 Pink P99 L99 99H 1 9/16 6 Systems LCAX500-58F-6 5/8 1.89 1.48 0.26 3.37 Pink P99 L99 99H 1 9/16 6 LCAX650-56F-6 5/16 1.95 1.45 0.30 2.50 Black P106 24 106H 1 1/2 6 LCAX650-38F-6 3/8 1.95 1.45 0.30 2.50 Black P106 24 106H 1 1/2 6 E2. 646.4 kcmil Labels LCAX650-12F-6 1/2 1.95 1.45 0.30 2.86 Black P106 24 106H 1 1/2 6 LCAX650-58F-6 5/8 1.95 1.45 0.30 3.42 Black P106 24 106H 1 1/2 6 LCAX750-12F-3 1/2 2.17 1.66 0.32 2.86 Yellow P115 L115 115H 1 3/4 3 E3. 777.7 kcmil Pre-Printed LCAX750-58F-3 5/8 2.17 1.66 0.32 3.67 Yellow P115 L115 115H 1 3/4 3 & Write-On See pages D3.70 D3.73 for tool and die information. Markers *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)