NetKey NK6 Category 6 U/UTP Copper Cable Europe DATA SHEET Category 6 cable shall meet the ISO 11801 Class E and ANSI/TIA-568-C.2 Category 6 NetKey Network Components channel standards. The conductors shall be 24 AWG insulated with polyethylene. The copper conductors shall be twisted in pairs, separated by NetKey UTP Copper Cable a cross divider and covered by a LSFRZH jacket. LSFRZH: NUW6C04**-CE NetKey Category 6 UTP Jack Module Punchdown: NK688MIW* NetKey Category 6 UTP Patch Cords CM technical information Foot lengths: NK6PC3 Y Meter lengths: NK6PC1M Y Electrical Certified channel performance in a 4-connector configuration up to NetKey Category 6 Punchdown performance: 100 meters and meets ISO 11801 Class E and ANSI/TIA-568-C.2 Patch Panels Category 6 standards at swept frequencies up to 250MHz. 12-port: NK6PPG12WY 24-port, 1 RU: NK6PPG24Y Conductors/ 24 AWG solid copper insulated with polyolefin 48-port, 2 RU: NK6PPG48Y insulators: NetKey Category 6 All Molded Flame rating: EN 50575: Euroclass B2ca-s1a-d1-a1 Punchdown Patch Panels 24-port, 1 RU: NK6PP24P PoE compliance: Meets IEEE 802.3af, IEEE 802.3at and IEEE 802.3bt for PoE applications 48-port, 2 RU: NK6PP48P Installation tension: 110 N (25 lbf) NetKey Flush Mount Modular Patch Panels Temperature rating: -20 C to 75 C (-4 F to 167 F) during operation Angled, 24-port, 0 C to 50 C (32 F to 122 F) during installation 1 RU: NKPPA24FMY Cable jacket: LSFRZH Angled, 48-port, 2 RU: NKPPA48FMY Cable diameter: 5.9mm (0.235 inch) nominal Flat, 24-port, 1 RU: NKPP24FMY Flat, 48-port, 2 RU: NKPP48FMY Cable weight: 12kg/305m (26 lbs./1000 ft.) NetKey Category 6 All Molded Packaging: 305m (1000 ft.) easy payout carton Modular Patch Panels 24-port, 1 RU: NKPP24P 48-port, 2 RU: NKPP48P key features and benefits Termination and Cable Prep Tools Easy payout carton Ensures proper performance and provides quick installation JackRapid Termination Tool: JR-PAN-2 Third party tested Cable has been tested as part of the NetKey Category 6 U/UTP Copper Conductor Cabling System by an independent laboratory and complies with the snipping tool: CWST Conductor electrical channel requirements of the following standards: ISO 11801 stripping tool: CJAST Class E and ANSI/TIA-568-C.2 Category 6 Descending length Easy indentification of remaining cable reduces installation time and ** Part number available in WH (White). For cable marking cable scrap additional colors, please contact Panduit Customer Service. Robust design Cross divider separates twisted pairs for robust cable design *For standard colors other than Off White (IW), replace suffix with EI (Electrical Ivory), IG (International Gray), WH (White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), or VL (Violet). Add -Q to end of part number for 25 pack convenience package. For standard foot lengths other than 3 feet, replace the 3 in the part number with 5, 7, 10, 14 or 20. For applications standard colors other than Off White, add suffix BU (Blue), RD (Red), YL (Yellow) or GR (Green) before NK6 U/UTP Copper Cable is a component of the Panduit NK6 U/UTP Copper Cabling System. This the Y at the end of the part number. For example, the part number for a blue, Category 6, 5-foot patch cord end-to-end system provides Gigabit Ethernet performance with usable bandwidth beyond 250MHz. is NK6PC5BUY. With certified performance the ISO 11801 Class E and ANSI/TIA-568-C.2 Category 6 standards, this For standard meter lengths other than 1 meter, replace the 1 in the part number with 2, 3, 4 or 5. For system will support the following applications: standard colors others than Off White, add suffix BU (Blue), RD (Red), YL (Yellow) or GR (Green) before Y at the end of the part number. For example, the part * Ethernet 10BASE-T number for a blue, Category 6, 5-meter patch cord is NK6PC5MBUY. *100BASE-T (Fast Ethernet) Fluke JackRapid Termination Tool available through *1000BASE-T (Gigabit Ethernet) distribution. To locate the local office, visit www.flukenetworks.com/contact. JackRapid is a trademark of Fluke Networks. www.panduit.com NetKey NK6 Category 6 U/UTP Copper Cable Europe additional specifications Mechanical Test Ultimate Breaking Strength >400 N (90 lbf.) Minimum Bend Radius 4 x cable diameter Electrical Test Nominal Velocity of Propagation (NVP) 65% cable construction Jacket Conductor Wire Conductor Insulator Cross Divider WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2018 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com NKDS61--WW-ENG or by phone: 800.777.3300 4/2018