TX7000 Shielded Copper Cable for Harsh Environments S/FTP SPECIFICA TION SHEET specifications Category 7 cable shall meet or exceed the IEC 61156-5 Category TX6A 10Gig Shielded 7 component standard and be characterized to 1000 MHz. Copper Cabling System The conductors shall be 23 AWG stranded copper wire construction with polyethylene insulation. The copper conductors shall be twisted in TX7000 S/FTP Copper Cable pairs each surrounded by a foil, covered with an overall braided shield within an oil- and fuel-resistant, low smoke zero halogen (LSZH) LSZH: PSM7004* jacket for use in harsh environment applications. Mini-Com TX6A 10Gig technical information Shielded Jack Module Electrical Certified channel performance in a 4-connector configuration up to 100 meters and Jack module: CJS6X88TGY performance: exceeds the requirements of ISO 11801 Class E and ANSI/TIA-568-C.2 Category A 6A standards for supporting 10GBASE-T transmission over twisted-pair cabling TX6A 10Gig Shielded systems as part of the Panduit TX6A 10Gig Shielded Copper Cabling System CM/LSZH Patch Cords Certified component performance up to 100 meters and meets or exceeds the Feet: STP6X**IG component requirement of the IEC 61156-5 Category 7 standard at swept Meters: STP6X***MIG frequencies up to 600 MHz Mini-Com All Metal Shielded Conductors/ 23 AWG stranded copper wire insulated with polyethylene insulators: Angled Modular Patch Panels Insulation diameter: 1.52-1.60mm (0.060-0.063 in.) 24-port, 1 RU: CPA24BLY 48-port, 2 RU: CPA48BLY Standards EN 50173-1, EN 50288-4-1, ISO/IEC 11801, IEC 61156-5, 72-port, 2 RU: CPA72BLY compliance: DNV specification number 6-827.50-2, IEC 60092-360 Mini-Com All Metal Shielded Certifications: DNV certification number E-14069, ABS certification number 10-HS638424-1-PDA Flat Modular Patch Panels Flame rating: IEC 60754-1, IEC 60754-2, IEC 61034-2, IEC 60332-1, IEC 60332-3-24 24-port, 1 RU: CP24BLY PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications 48-port, 2 RU: CP48BLY Chemical Mineral oil IRM 902 (IEC 60811-2-1) 7 days/23C (73F) 4 hours/70C (158F) 72-port, 2 RU: CP72BLY resistance: Diesel fuel IRM 903 (IEC 60811-2-1) 7 days/23C (73F) 4 hours/70C (158F) Cable Prep Tools Installation tension: 100 N maximum (22 lbf) Wire Temperature rating: -15C to 50C during installation (5F to 122F) snipping tool: CWST -40C to 85C during operation (-40F to 185F) Wire Cable jacket: Oil- and fuel-resistant low smoke zero halogen (LSZH) (IEC 60332-3c),SHF1 stripping tool: CJAST Cable diameter: 7.9mm (0.314 in.) nominal *Cable color is IG (International Gray) and/or Cable weight: 38 kg/500 m (84 lbs./500 m) BU (Blue). For other cable colors please contact customer service. Packaging: 500 or 1000 meters (1640 or 3280 feet) on a reel **For lengths 3 to 20 feet (increments of Package tested to ISTA Procedure 1A or 1B one foot) and 25, 30, 35, 40 feet, change the length designation in the part number to desired length. For standard cable colors key features and benefits other than IG (International Gray) substitute IG suffix with Bl (Black), BU (Blue), 23 AWG stranded Provides exceptional signal strength and electrical performance for high GR (Green), RD (Red), YL (Yellow), conductor wire vibration environments OR (Orange), or VL (Violet) to the end of the part number. For example the part Individually foiled Foil prevents coupling near-end crosstalk and alien crosstalk between pairs number for a blue, 15-foot patch cord pairs with overall while shield reduces low-frequency external interference to ensure is STP6X15BU. braided shield 10GBASE-T performance ***For lengths 1 to 10 meters (increments Robust jacketing Oil- and fuel-resistant for harsh environments of one meter) and 1.5, 2.5, 15, 20 meters, change the length designation in the part Guaranteed channel Industry leading guaranteed channel performance above the TIA/ISO standards number to the desired length. For standard performance above with headroom warranty cable colors other than IG (International the standards Gray) substitute IG suffix with BL (Black) BU (Blue), GR (Green), RD (Red), Tested beyond Cable has been characterized to 1000 MHz, 400 MHz above the standard YL (Yellow), OR (Orange), or VL (Violet) the standards to the end of the part number. For example, the part number for a blue, 15-meter patch Descending length Easy identification of remaining cable reduces installation time and cable scrap cord is STP6X15MBU. cable markings Contact customer service for bulk packaged and/or keyed jack modules and patch cords. Bulk packaging Supplied in reels for ease of installation Third party tested Exceeds the application requirements of Det Norske Veritas, American Bureau of Shipping, and ETL applications TX7000 Shielded Copper Cable is a component oil-resistant jacket used in the TX7000 S/FTP of the TX6A 10Gig Shielded Copper Cabling System. Shielded Copper Cable makes it the ideal choice This end-to-end system provides a for use in harsh environments. The use of shielding in cost-effective media for ensuring that the most the cable offers superior performance in uncertain high challenging network bandwidth needs are easily EMI environments for ultimate signal integrity. met today and tomorrow. The durable flame- and www.panduit.com TX7000 Shielded Copper Cable for Harsh Environments S/FTP additional specifications Mechanical Test Ultimate Breaking Strength >400 N (90 lbf) Minimum Bend Radius 8 x cable diameter Electrical Test Nominal Velocity of Propagation (NVP) 76% nominal Operating Voltage, Maximum 80 V cable construction Stranded Conductor Insulator Conductor Wire Foil Shield Jacket Overall Braid product offering Part Number Packaging Configuration Reel Size PSM7004*-KED Standard Euro Pallet 500m (12 reels/pallet) PSM7004*-KEM Standard Euro Pallet 1000m (4 reels/pallet) *Cable color is IG (International Gray) or BU (Blue). For other cable colors, please contact customer service. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2015 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com COSP304--WW-ENG 3/2015 or by phone: 800.777.3300