TX6500 Premium Category 6 U/UTP Copper Cable SPECIFICATION SHEET specifications TX6500 Category 6 UTP Copper Category 6 cable shall far exceed ANSI/TIA-568-C.2 Cabling System and ISO 11801 Class E standards. The conductors shall be 23 AWG construction with FEP (CMP) or polyolefin (CMR) insulation. The copper conductors shall be twisted TX6500 Category 6 U/UTP in pairs, separated by an integrated pair divider and shall Copper Cable be covered by a low smoke, flame-retardant (CMP) jacket Plenum: PUP6504*-UY or a flame-retardant (CMR) jacket. Riser: PUR6504*-UY technical information Mini-Com TX6 PLUS UTP Jack Module Electrical Certified channel performance in a 4-connector configuration up to 100 performance: meters and exceeds ANSI/TIA-568-C.2 Category 6 and ISO 11801 Jack module: CJ688TG** Class E standards at swept frequencies up to 250 MHz TX6 PLUS UTP Patch Cords Certified component performance up to 100 meters and exceeds the component requirements of ANSI/TIA-568-C.2 Category 6 and IEC Foot lengths: UTPSP3***Y 61156-5 component standards at swept frequencies up to 250 MHz Meter lengths: UTPSP1M Y Standards UL Listed CMP-LP (0.5A) for Plenum DP6 PLUS Angled Punchdown compliance: Patch Panels Conductors/ Plenum 23 AWG bare copper wire covered by FEP insulation 24-port, 1 RU: DPA24688TGY insulators: Riser 23 AWG bare copper wire covered by polyolefin insulation 48-port, 2 RU: DPA48688TGY Flame rating: Plenum NFPA 262 and CSA FT-6 DP6 PLUS Flat Punchdown Riser UL 1666 and CSA FT-4 Patch Panels PoE compliance: Meets IEEE 802.3af, IEEE 802.3at and IEEE 802.3bt for PoE applications 12-port: DP12688TGY Installation tension: 25 lbf. (110 N) maximum 24-port, 1 RU: DP24688TGY Temperature rating: Plenum 32F to 122F (0C to 50C) during installation 48-port, 2 RU: DP48688TGY -4F to 194F (-20C to 90C) during operation GP6 PLUS Category 6 Riser 32F to 122F (0C to 50C) during installation Punchdown System -4F to 167F (-20C to 75C) during operation See website (www.panduit.com) or catalog for Cable jacket: Plenum low smoke, flame-retardant PVC complete system information. Riser flame-retardant PVC Cable Prep Tools Cable diameter: Plenum 0.264 in. (6.7mm) nominal Riser 0.265 in. (6.8mm) nominal Wire snipping tool: CWST Cable weight: Plenum 32 lbs./1000 ft. (14.5 kg/305m) Wire stripping tool: CJAST Riser 30 lbs./1000 ft. (13.6 kg/305m) *To designate color, add suffix BU (Blue), WH (White), YL (Yellow), or IG (Intl Gray). Packaging: 1000 ft. (305m), EZ-Brake Reel-in-a-Box For additional cable colors, contact Packaging tested to ISTA Procedure 1A customer service **To designate color, add suffix IW (Off White), EI (Electric Ivory), IG (International Gray), key features and benefits WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green), Third party tested Cable has been tested as part of the TX6500 Copper Cabling YL (Yellow), or VL (Violet). System by an independent laboratory and complies with the electrical channel requirements of the following standard: ***For lengths 1 to 20 feet (increments of one foot) and 25, 30, 35, 40 feet, change the ANSI/TIA-568-C.2 Category 6 length designation in part number to the Guaranteed channel performance Industry leading guaranteed channel performance above desired length. For standard cable colors above the standards the TIA/ISO standards with headroom guarantee other than Off White, add suffix BL (Black), BU (Blue), GR (Green), RD (Red), YL (Yellow), Integrated pair divider Separates pairs for exceptional cable performance OR (Orange), or VL (Violet) before Y at the end of the part number. For example, the EZ-Brake Reel-in-a-Box Ensures proper performance and provides quick installation part number for a blue 15-foot patch cord Tested beyond the standards Cable has been characterized to 600 MHz, 350 MHz above is UTPSP15BUY. the standard For lengths 1 to 10 meters (increments of one Extended temperature range Allows operation in 90C (194F) ambient environment providing meter) and 0.5, 1.5, 2.5, 15, 20 meters, change error-free performance in high-density cabinets and large the length designation in the part number to the desired length. For standard cable colors cable bundles running PoE+ or PoE++ applications other than Off White, add suffix BL (Black), Reduced attenuation Maximizes the amount of signal that reaches the receiver BU (Blue), RD (Red), YL (Yellow), GR (Green), and increases bandwidth OR (Orange), or VL (Violet) before Y at the end of the part number. For example, the part number for a blue, 5-meter patch cord applications is UTPSP5MBUY. TX6500 U/UTP Copper Cable is a component of the Panduit TX6500 Copper Cabling System. Interoperable and backward compatible, this end-to-end system provides design flexibility to protect network investments well into the future. With certified performance to the ANSI/TIA-568-C.2 Category 6 and ISO 11801 Class E standards, this system will support the following applications: Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet), 10GBASE-T (10 Gigabit Ethernet over limited distances as specified in the industry 10GBASE-T standards) www.panduit.com TX6500 Premium Category 6 U/UTP Copper Cable additional specifications Mechanical Test Ultimate Breaking Strength >90 lbf (400N) Minumum Bend Radius 4 x cable diameter Electrical Test Nominal Velocity of Propagation (NVP) CMP 73% nominal CMR 70% nominal Operating Voltage, Maximum 80 V cable construction Jacket Conductor Wire Conductor Insulator Cross Divider WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2017 Panduit Corp. ALL RIGHTS RESERVED. Visit us at www.panduit.com COSP258--WW-ENG Contact Customer Service by email: cs panduit.com Replaces WW-COSP137 or by phone: 800.777.3300 and reference COSP258 3/7/2017