ELECTRICAL SOLUTIONS A. System Overview 2x2 and 4x4 Fiber-Duct Routing Systems Channel, covers, fittings and other non-metallic system Compatible with Panduit FiberRunner 2x2, 4x4, B1. components made from V-0 flame class rated material 6x4 and 12x4 Routing Systems Cable Ties Snap-on non-slip covers B2. Std. Std. Cable System Pkg. Ctn. Accessories Part Number Part Description Size Qty. Qty. Fiber-Duct Channel B3. S2X2YL6NM Used to carry the cables throughout the 2x2 6 120 Stainless Fiber-Duct Routing System. Accepts cover C2YL6. Steel Ties S2X2 Cover sold separately. S4X4 S4X4YL6NM Used to carry the cables throughout the 4x4 6 60 C1. Fiber-Duct Routing System. Accepts cover C4YL6. Wiring Cover sold separately. Duct Fiber-Duct Slotted Channel E2X2YL6 Used to carry the cables vertically to the front or 2x2 6 120 C2. the back of equipment racks throughout the system. Surface Accepts cover C2YL6. Extra supports required Raceway when used in horizontal applications. Cover sold separately. C3. E4X4YL6 Used to carry the cables vertically to the front or 4x4 6 60 Abrasion E2X2 the back of equipment racks throughout the system. Protection E4X4 Accepts cover C4YL6. Extra supports required when used in horizontal applications. Cover sold separately. C4. Cable Fiber-Duct Cover Management C2YL6 Cover for Fiber-Duct Channel and Fiber-Duct 2x2 6 120 Slotted Channel. Non-slip cover design incorporates integral high friction lining to inhibit cover movement. D1. Terminals C4YL6 Cover for Fiber-Duct Channel and Fiber-Duct 4x4 6 120 Slotted Channel. Non-slip cover design incorporates integral high friction lining to inhibit cover movement. D2. C2 Power C4 Connectors Note: Available with mounting holes. To order, delete NM from the part number. For fastest installation use NR2WH-L or NR4BL-L snap rivets. For other colors replace YL (Yellow) with OR (Orange) or BL (Black). D3. Order number of feet required, in multiples of standard 6 length increments. Grounding Connectors E1. Labeling Fiber-Duct System Fittings Systems Std. Std. System Pkg. Ctn. E2. Part Number Part Description Size Qty. Qty. Labels Coupler Fitting FCF2X2 FCF2X2YL Used to join two sections of duct together. 2x2 1 5 FCF4X4 E3. Fiber-Duct Coupler is not required at each Pre-Printed FCF4X4YL 4x4 1 5 & Write-On fitting connection. Markers Horizontal Right Angle Fitting E4. FRA2X2YL Attaches to channel to create a 90 horizontal turn 2x2 1 5 FRA2X2 Permanent from a straight horizontal run. Cover included. FRA4X4YL 4x4 1 5 FRA4X4 Identification For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black). E5. Fittings include 5/16 assembly holes for fast mechanical fastening. Lockout/ Tagout & Safety Solutions F. Index Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.ELECTRICAL SOLUTIONS A. System Overview Fiber-Duct System Fittings (continued) B1. Std. Std. Cable Ties System Pkg. Ctn. Part Number Part Description Size Qty. Qty. B2. Horizontal Tee Fitting Cable FT2X2 FT2X2YL Attaches to channel to create a 90 horizontal 2x2 1 5 Accessories FT4X4 branch from a straight horizontal run. FT4X4YL 4x4 1 5 Cover included. B3. Stainless Four Way Cross Fitting Steel Ties FFWC2X2YL Attaches to channel to create a horizontal four 2x2 1 5 way cross intersection. Cover included. FFWC2X2 FFWC4X4YL 4x4 1 5 C1. FFWC4X4 Wiring End Cap Fitting Duct Used for closing off open ends of the channel. 2x2 1 5 FEC2X2YL No coupler required. Push-on installation. C2. FEC4X4YL 4x4 1 5 FEC2X2 Surface FEC4X4 Raceway Inside Vertical 45 Angle Fitting FIV452X2YL Attaches to channel to create a 45 upward angle 2x2 1 5 C3. from a straight horizontal run. Used with outside Abrasion vertical 45 angle fitting FOV452X2YL or Protection FIV454X4YL 4x4 1 5 FOV454X4YL to change level of straight horizontal runs. Cover included. FIV452X2 C4. FIV454X4 Outside Vertical 45 Angle Fitting Cable Management FOV452X2YL Attaches to channel to create a 45 downward 2x2 1 5 angle from a straight horizontal run. Used with inside vertical 45 angle fitting FIV452X2YL or FOV454X4YL 4x4 1 5 FIV454X4YL to change level of straight D1. horizontal runs. Cover included. Terminals FOV452X2 Inside Vertical Right Angle Fitting FOV454X4 FIVRA2X2YL Attaches to channel to create a 90 upward angle 2x2 1 5 D2. from a straight horizontal run. Used with outside Power Connectors vertical 90 angle fitting FOVRA2X2YL or FIVRA4X4YL 4x4 1 5 FOVRA4X4YL to change level of straight horizontal runs. Cover included. D3. Grounding FIVRA2X2 Outside Vertical Right Angle Fitting Connectors FIVRA4X4 FOVRA2X2YL Attaches to channel to create a 90 downward 2x2 1 5 angle from a straight horizontal run. Used with inside vertical 90 angle fitting FIVRA2X2YL or E1. FOVRA4X4YL 4x4 1 5 Labeling FIVRA4X4YL to change level of straight Systems horizontal runs. Cover included. 4x4 to 2x2 Fiber-Duct Reducer Fitting FOVRA2X2 E2. FRF42YL Joins any 4x4 Fiber-Duct Fitting to the 2x2 2x2 15 FOVRA4X4 Labels Fiber-Duct Channel, S2X2YL6 or E2X2YL6. 4x4 Includes cover. E3. For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black). Pre-Printed Fittings include 5/16 assembly holes for fast mechanical fastening. & Write-On Markers FRF42 E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)