Panduct Type TNC Low-Smoke, Halogen-Free, Slotted Wall Wiring Duct SPECIFICATION SHEET specifications TNC Wiring Duct (Base and Cover) Type TNC wiring duct shall be a flush cover, slotted wiring duct and be made from low-smoke and halogen-free (LSHF) material that Size mm (in.) meets the regulatory requirements of the mass transit industry and 25.0 (1.00) x 37.0 (1.50): other regulated environments. The low-smoke and halogen-free TNC25X37LG2 material will have a UL flammability rating of UL94 V-0 and will meet 25.0 (1.00) x 75.0 (3.00): 1 the National Fire Protection Association Standard NFPA 130 and TNC25X75LG2 2 Federal Rail Administration Guidelines for rail transit vehicles. Type 37.0 (1.50) x 37.0 (1.50): 3 TNC wiring duct shall be compliant with DIN 5510-2 preventative fire TNC37X37LG2 protection in railway vehicles, with S-4 burning class, SR-2 smoke 37.0 (1.50) x 75.0 (3.00): class, and ST-2 dripping class ratings. TNC37X75LG2 50.0 (2.00) x 50.0 (2.00): technical information TNC50X50LG2 75.0 (3.00) x 75.0 (3.00): Low-smoke, Non-toxic, lead-free, and environmentally safe will not exhibit a high rate TNC75X75LG2 halogen-free material: of smoke generation or release toxic, corrosive gases in the event of a 100.0 (4.00) x 50.0 (2.00) fire that could endanger public safety or damage sensitive electronics in TNC100X50LG2 enclosed environments (passenger rail, oil and gas platforms) 100.0 (4.00) x 75.0 (3.00): UL94 V-0 material Self-extinguishing and provides a greater flame resistance when compared TNC100X75LG2 flame rating: to other halogen-free wiring duct, enabling its use in more electrical applications 4 Replacement Covers Temperature range: Continuous use up to a maximum of 105C (221F) shipping, handling, and installation to -70C (-94F) Size mm (in.) 1 25.0 (1.00): TNC25LG2 Rail standard NFPA 130 3 compliance/rating: DIN 5510-2 37.0 (1.50): TNC37LG2 5 BSS 7239 50.0 (2.00): TNC50LG2 6 AFNOR NF F 16 101 and NF F 16 102 50.0 (2.00): TNC75LG2 7 UNIFER EN UNI 11925-2 (EN ISO 11925-2) 100.0 (4.00): TNC100LG2 8 EN 455545-2 Divider Wall Compliance: RoHS REACH compliant UL recognized. LSHF 50mm (2) solid divider wall: TNC50D2 LSHF 75mm (3) solid divider wall: TNC75D2 key features and benefits Divider wall Wide-finger/ Provides greater sidewall rigidity and allows use with a wide range mounting disc: DB-C slot design of wire and bundle sizes Tools and Accessories Flush cover design Base sidewall is even with cover for superior aesthetics and greater wiring Duct cutting tool: DCT capacity when compared to non-flush cover wiring duct Notching tool: DNT-100 Non-slip cover liner Halogen-free liner ensures that the cover does not slide during shipment, Nylon rivet vibration, and when in a vertical orientation, eliminating rework and repositioning installation tool: TNR Nylon rivet: NR1 Base and finger Score lines allow for easy breakouts, saving installation time, when score lines compared to other halogen-free duct Duct finger cutting tool: DFCT Low-smoke, Used to create multiple channels within a single duct to separate cabling halogen-free types (power communication/signal) installed with DB-C mounting discs divider wall applications Type TNC wiring duct routes, protects, and manages and toxicity) such as in light rail and transit systems, electrical and communication cabling in control panels commuter buses, data centers, offshore oil and gas and wire routing applications that require enhanced platforms, and other environments. material performance for fire safety (flame, smoke, 1 NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems, 2000 edition. 2 Per Code of Federal Regulation 49 C.F.R. Part 223, 238. 3 German Standard DIN 5510-2 DIN 54837 (test method). 4 Maximum temperature based on material Heat Deflection Temperature (HDT) data. 5 Boeing Standard 7239 -- test method for toxic gas generation by materials on combustion. 6 French Standard AFNOR NF F 16 101 Railway Rolling Stock Fire Behaviour and Choice of Materials, NF F 16 102 Railway Rolling Stock Fire Behaviour: Material choosing, application for electric system. 7 UNIFER Italian Railway Standard EN UNI 11925-2 (EN ISO 11925-2). 8 EN 45545-2 (EU Standard: Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components. www.panduit.com Panduct Type TNC Low-Smoke, Halogen-Free, Slotted Wall Wiring Duct C 25.0 0.98 TYP 8.0 0.32 14.0 0.55 6.5 0.26 T D B H 25.0 50.0 12.5 0.49 0.98 1.97 4.5 0.18 A 10.0 0.39 TYP For 37mm and 50mm height duct For 25mm, 37mm and 50mm width duct* C 25.0 0.98 TYP 14.0 0.55 6.5 0.26 8.0 0.32 T 25.0 D 0.98 H B 25.0 0.98 25.0 50.0 10.0 0.39 TYP 0.98 1.97 4.5 0.18 A 12.5 0.49 For 75mm and 100mm height duct For 75mm and 100mm width duct* Dimensions - mm (In.) Duct Part Nominal Size A B C D H T Number W x H mm (in.) 2.0 TNC25X37LG2 25 x 37 (1 x 1.5) 24.6 (0.97) 35.8 (1.41) 24.6 (0.97) 24.7 (0.97) 33.0 (1.30) 1.7 (0.07) 0.08 1.5 TNC25X75LG2 25 x 75 (1 x 3) 24.6 (0.97) 72.4 (2.85) 24.6 (0.97) 57.6 (2.27) 70.5 (2.78) 2.0 (0.08) 64.9 2.55 0.06 TNC37X37LG2 37 x 37 (1.5 x 1.5) 37.1 (1.46) 35.8 (1.41) 37.1 (1.46) 24.7 (0.97) 33.0 (1.30) 1.8 (0.07) 40.2 1.58 TNC37X75LG2 37 x 75 (1.5 x 3) 37.1 (1.46) 72.4 (2.85) 37.1 (1.46) 57.6 (2.27) 70.5 (2.78) 2.0 (0.08) TNC50X50LG2 50 x 50 (2 x 2) 49.6 (1.95) 47.8 (1.88) 49.6 (1.95) 34.8 (1.37) 45.5 (1.79) 2.0 (0.08) TNC75X75LG2 75 x 75 (3 x 3) 74.6 (2.94) 72.4 (2.85) 74.6 (2.94) 57.6 (2.27) 70.5 (2.78) 2.0 (0.08) TNC100X50LG2 100 x 50 (4 x 2) 99.6 (3.92) 47.8 (1.88) 99.6 (3.92) 34.8 (1.37) 45.5 (1.79) 2.0 (0.08) 19.1 0.75 19.1 0.75 TNC100X75LG2 100 x 75 (4 x 3) 99.6 (3.92) 72.4 (2.85) 99.6 (3.92) 57.6 (2.27) 70.5 (2.78) 2.5 (0.10) Divider wall for 50mm and 75mm Dimensions shown are for reference only. Dimensions above are mm (inches). Duct and divider wall supplied in height duct two meter length. *Mounting hole pattern according to DIN 43659. TNC Wiring Duct Material (PPE+HIPS) TNC Wiring Duct Material (PPE+HIPS) Properties General Test Method Properties Mechanical Test Method Specific Gravity 1.11 g/cc ASTM D 792 Tensile Strength at Yield 8,100 psi ASTM D 638 Tensile Modulus 355,000 psi ASTM D 638 Heat Deflection 106C ASTM D 648 Temperature 264 psi 223F Flexural Strength at Yield 11,500 psi ASTM D 790 Flame/Smoke/Toxicity Flexural Modulus 340,000 psi ASTM D 790 Notched Izod Impact Strength Smoke Density (Flaming) Ds 1.5 min = 16 3.7 ft-lb/in. ASTM D 256 ASTM E 662 23C (73F) 1.5 and 4 min. Ds 4.0 min = 66 Regional Standards Flammability Class V-0 UL94 NFPA 130 (U.S. Standard for Pass Flame Spread Index Is =15 ASTM E 162 ASTM E 162 Fixed Guideway Transit and (ls<35, Ds1.5<100, 2 ASTM E 662 Total Heat Release 66.21 MJ/m ASTM E1354 Passenger Rail Systems) Ds4<200) Low Toxicity Yes BSS 7239 Burning class: S-4 DIN 5510 (Preventative fire DIN 5510-2 DIN Smoke class: SR-2 PPE + HIPS (Polyphenylene Ether + High Impact Polystyrene) protection in railway vehicles) 54837 Dripping class: ST-2 NF X 1-702 NF F16 101, NF F 16 102 NF X 70-100 (smoke density, toxicity, glowing F1/I4 NF EN 60695-2 filament, oxygen index) NF EN ISO 4589-2 UNIFER EN UNI 11925-2 Pass Italian Railway Standard (EN ISO 11925-2) WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2018 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. WDSP29--SA-ENG Contact Customer Service by email: cs panduit.com Replaces WDSP25--WW-ENG or by phone: 800.777.3300 1/2018