DP6A 10Gig Punchdown Patch Panels SPECIFICA TION SHEET TX6A 10Gig UTP Copper Cabling System with MaTriX Technology specifications DP6A 10Gig Angled Punchdown Category 6A/Class E , punchdown patch panels shall terminate A Patch Panels 4-pair, 22 26 AWG, 100 ohm unshielded twisted pair cable with 24-port, 1 RU: DPA246X88TGY an industry standard single wire 110 punchdown tool. Patch panels 48-port, 2 RU: DPA486X88TGY shall include a universal label coded for T568A and T568B wiring DP6A 10Gig Flat Punchdown schemes and mount to 19 and 23 racks. Patch panels shall be Patch Panels easy to identify with pre-printed numbers, write-on areas and 24-port, 1 RU: DP246X88TGY optional label kits. The DP6A 10Gig Punchdown Patch Panel must 48-port, 2 RU: DP486X88TGY be installed as part of the TX6A 10Gig UTP Copper Cabling System to achieve IEEE 10GBASE-T certified performance. TX6A 10Gig UTP Copper Cable with MaTriX Technology (100 meter solution) technical information Plenum: PUP6A04*-UG Category 6A/Class E Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6A A Riser: PUR6A04*-UG channel and component and ISO 11801 Class E standards for supporting 10GBASE-T A LSZH: PUL6A04-+G performance: transmission over twisted pair cabling systems in a 4-connector CM: PUC6A04-+G configuration up to 100 meters at swept frequencies 1 to 500 MHz TX6A 24 AWG 10Gig UTP Patch Cords Exceeds component requirements of ANSI/TIA-568-C.2 Category 6A and ISO 11801 Class E standards at swept frequencies Foot lengths: UTP6A A 1 to 500 MHz Meter lengths: UTP6A M FCC and ANSI compliance: Meets ANSI/TIA-1096-A contacts plated with 50 microinches TX6A-SD 26 AWG 10Gig UTP Patch Cords of gold for superior performance Foot lengths: UTP6ASD IEC compliance: Meets IEC 60603-7 Meter lengths: UTP6ASD M PoE compliance: Supports IEEE 802.3af, 802.3at, and IEEE 802.3bt type 3 and 4 for PoE applications up to 100 W TX6A 28 AWG 10Gig UTP Patch Cords UL rated: UL 1863 approved Foot lengths: UTP28X Conductor termination Compatible with 22 26 AWG solid or stranded IWC cable Meter lengths: UTP28X M range: with conductor insulation diameters of 0.048 in. Tools and Accessories Mounting option: Mounts to standard EIA 19 or 23 racks (with optional Wire snipping tool: CWST extender bracket) Wire stripping tool: CJAST Packaging: Punchdown tool: PDT110 Includes M6 and 12-24 mounting screws 24-port label kit: DPLK24 48-port label kit: DPLK48 key features and benefits Replacement 100% performance tested Confidence that each jack module will deliver the critical module: DRJ6X88TGBL electrical performance requirements Strain relief bar: SRBM19BLY or SRB19D7BL Advanced electrical Headroom over industry standards for lower risk and high Extender bracket: PEB1 compensation technology bandwidth availability Clear dust cap: MDC-C Individually serialized Each port is marked with quality control number for Block out device: PSL-DCJB- future traceability Phone icons: CIPIW-C RJ45 interface Industry standard interface provides a quick and easy plug and Data icons: CIDIW-C play connection to RJ45 patch cords backwards compatible Identification Can be clearly identified with optional labels and icons for *To designate color, add suffix BU (Blue) or WH (White). For additional cable colors, contact customer service. port identification +Add suffix E when ordering for countries in Europe, Universal wiring scheme T568A and T568B wiring schemes clearly identified Middle East, or Africa. Industry standard PDT110 single wire 110 punchdown tool termination tool ensures For lengths 3 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length termination tool conductors are fully terminated designation in the part number to the desired length. Block out device (optional) Provides a simple and secure method to control access to data For standard cable colors other than Off White, add ports while not in use suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), Angled design (optional) Facilitates proper bend radius control and minimizes the need GR (Green), OR (Orange) or VL (Violet). For example, the part number for a blue 15-foot patch cord is for horizontal cable managers UTP6A15BU. Replacement port module Ability to replace field damaged ports for complete For lengths 3 to 10 meters (one meter (optional) panel utilizations increments) and 2.5, 15, 20, 25, 30, 35, 40 meters, change the length designation in the part number to the desired length. For standard applications cable colors other than Off White IG, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), DP6A 10Gig Punchdown Patch Panels are a Class E Edition 2.1, IEEE 802.3an-2006 and A GR (Green), OR (Orange) or VL (Violet). For example, component of the TX6A 10Gig UTP Copper ANSI/TIA-568-C.2 Category 6A standards, this the part number for a blue 15-meter Cabling System with MaTriX Technology. This system will support high bandwidth applications patch cord is UTP6A15MBU. end-to-end system provides a cost effective with data centers and connections to high end To designate color other than Red, add medium for ensuring that network bandwidth workstations such as stacking switches and suffix BL (Black), BU (Blue), YL (Yellow), needs are easily met today and tomorrow. switch-to-switch links, storage area networks, GR (Green), OR (Orange), IW (Off White) or IG (International Gray) at the end of the part The Panduit solution helps ensure organizations aggregation of Gigabit Ethernet channels, real-time number. 10/package. efficiently and reliably meet their data transmission intensive financial transactions, streaming video, To designate color other than IW (Off White), needs. With certified performance to the ISO 11801 animation, scientific modeling and medical imaging. replace IW with EI (Electric Ivory), IG (International Gray), BL (Black), BU (Blue), www.panduit.com RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet) in the part number. 100/package. DP6A 10Gig Punchdown Patch Panels Test Results Mechanical Test Test Method Measurement Typical Test Results Normal Force Load (grams) >100 Vibration IEC 512-6d Circuit Resistance (mOhms) <40 Shock IEC 512-6c Contact Disturbance (microseconds) <5 Durability IEC 512-9a Circuit Resistance (mOhms) <40 Mating Force (N) <20 Mating/Un-Mating IEC 512-13b Un-Mating Force (N) <20 Termination Cycles IEC 352 Number of Cycles <20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) <20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (mOhms) >500 Environmental Test Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) <40 Humidity IEC 512-11c Circuit Resistance (mOhms) <40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) <40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) <40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) <40 17.42 442.5 17.42 442.5 19.0 482.6 1.17 29.6 19.0 482.6 1.17 29.6 3.47 1.72 24-Port DP6A Patch Panel 48-Port DP6A Patch Panel 88.1 43.7 4.75 120.6 4.75 120.6 19.0 482.6 19.0 482.6 1.72 3.47 24-Port DP6A Angled Patch Panel 48-Port DP6A Angled Patch Panel 88.1 43.7 Dimensions are in inches. Dimensions in brackets are metric . WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2016 Panduit Corp. ALL RIGHTS RESERVED. Visit us at www.panduit.com COSP245--WW-ENG Contact Customer Service by email: cs panduit.com Replaces WW-COSP144 2016-08-25 or by phone: 800.777.3300 and reference COSP245