Mini-Com TX5e Corrosive Resistant UTP Jack Modules SPECIFICATION SHEET specifications Category 5e/Class D, 8-position, UTP jack module shall terminate 4-pair, 22 26 AWG, 100 ohm unshielded twisted pair cable and shall not require use of a punchdown tool. Polymer based gel shall protect electrical contacts and internal components by reducing the ingress of TX5500 UTP Copper moisture and other corrosive elements such as salt, providing improved Cabling System long term performance. UTP jack modules shall use a forward motion termination method to optimize performance by maintaining cable pair Mini-Com TX5e Corrosive geometry while eliminating conductor untwist. The termination cap shall Resistant UTP Jack Module be color-coded red to designate Category 5e performance and shall include a universal label coded for T568A and T568B wiring schemes. Jack module: CJE5E88TGIW* TX5500 UTP Copper Cable Plenum: PUP5504** technical information Riser: PUR5504** LSZH: PUL5504** Category 5e/Class D Exceeds channel requirements of ANSI/TIA-568-C.2 Category 5e CM: PUC5504** channel and component and ISO 11801 Class D standards at swept frequencies 1 to 100 MHz TX5e UTP Patch Cords performance: Exceeds component requirements of ANSI/TIA-568-C.2 Category 5e CM (Foot lengths): UTPCH Y and ISO 11801 Class D standards at swept frequencies 1 to 100 MHz CM (Meter lengths): UTPCH MY LSZH (Meter lengths): UTPCHL MY FCC and ANSI Meets all applicable ANSI/TIA-968-A requirements contacts plated compliance: with 50 microinches of gold for superior performance Mini-Com Angled Modular IEC compliance: Meets IEC 60603-7 Patch Panels PoE compliance: Meets requirements of IEEE 802.3af and IEE 802.3at for PoE applications 24-port, 1 RU: CPPLA24WBLY 48-port, 2 RU: CPPLA48WBLY UL rated: UL 1863 approved Mini-Com Flat Modular Conductor termination Wire cap compatible with 22 26 AWG solid or stranded cable with Patch Panels range: conductor insulation diameters of 0.060 in. max and overall cable O.D. 0.200 in. to 0.330 in. 24-port, 1 RU: CPPL24WBLY 48-port, 2 RU: CPPL48WBLY For additional modular and punchdown patch panels, visit www.panduit.com. key features and benefits Pan-Punch 110 Punchdown System Polymer based gel Protects electrical contacts and internal components by reducing the See website (www.panduit.com) or catalog for complete system information. ingress of moisture and other corrosive elements such as salt, providing improved long term performance operation life 75+ insertions Tools and Accessories High temperature Enables operations in environments up to 70C ideal for use in warm Jack module resistant material temperature environments or network hot spots termination tools: EGJT or TGJT 100% performance tested Confidence that each jack module will deliver the critical electrical Wire snipping tool: CWST performance requirements Wire stripping tool: CJAST Clear dust cap: MDC-C Utilizes enhanced Optimizes performance by eliminating conductor untwist and reduces Block out device: PSL-DCJB- Giga-TX Technology installation time and expense Phone icons: CIPIW-C Improved termination cap Conductor retention slots simplify jack module termination Data icons: CIDIW-C Modular UTP jack modules snap in and out of all Mini-Com Faceplates, *To designate color other that IW (Off White), replace Modular Patch Panels and Surface Mount Boxes for easy moves, IW suffix with WH (White), BL (Black), RD (Red), or adds and changes BU (Blue). ** To designate color, add suffix BU (Blue) or True strain relief Controls cable bend radius for long-term installed performance WH (White). For additional cable colors, contact Individually serialized Marked with quality control number for future traceability customer service. For lengths 1 to 20 feet (one foot increments) RJ45 interface Industry standard interface provides a quick and easy plug and play and 25, 30, 35, 40 feet, change the length designation connection to RJ45 patch cords backwards compatible in the part number to the desired length. For standard Identification Can be clearly identified with optional labels and icons for port identification cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), Termination tools (optional) EGJT termination tool ensures conductors are fully terminated by utilizing OR (Orange), or VL (Violet). For example, the part a smooth forward motion without impact on critical internal components for number for a blue 15-foot patch cord is UTPCH15BUY. maximum reliability TGJT termination tool ideal for high volume installations For lengths 1 to 10 meters (one meter increments) and 2.5, 15, 20, 25, 30, 35, 40 meters, change the Block out device (optional) Provides a simple and secure method to control access to data ports length designation in the part number to the desired while not in use length. For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange), or VL (Violet). For example, the part number for a blue 15-meter patch cord is UTPCH15MBUY. applications To designate color other than Red, add suffix BL (Black), BU (Blue), YL (Yellow), GR (Green), OR Mini-Com TX5e Corrosive Resistant UTP Jack Ethernet 10BASE-T, 100BASE-T (Fast (Orange), IW (Off White) or IG (International Gray) at Modules are a component of the TX5500 UTP Ethernet), 1000BASE-T (Gigabit Ethernet) the end of the part number. 10/package. Copper Cabling System. This end-to-end system 155 Mb/s ATM, 622 Mb/s ATM To designate color other than IW (Off White), replace IW with EI (Electric Ivory), IG (International Gray), provides Gigabit Ethernet performance with usable Token ring 4/16 BL (Black), BU (Blue), RD (Red), YL (Yellow), bandwidth beyond 100 MHz. With certified Voice/data systems GR (Green), OR (Orange), or VL (Violet) in the performance to the ANSI/TIA-568-C.2 Category 5e Voice over Internet Protocol (VoIP) part number. 100/package. and ISO 11801 Class D Edition 2.1 standards, this Contact customer service for bulk packaged system will support the following applications: and/or keyed jack modules and patch cords. www.panduit.com Mini-Com TX5e Corrosive Resistant UTP Jack Modules test results Mechanical Test Test Method Measurement Typical Test Results Normal Force Load (grams) > 100 < 40 Vibration IEC 512-6d Circuit Resistance (mOhms) Shock IEC 512-6c Contact Disturbance (microsecond) < 5 < 40 Durability IEC 512-9a Circuit Resistance (mOhms) Mating/Unmating IEC 512-13b Mating Force (N) < 20 Unmating Force (N) < 20 Termination Cycles IEC 352 Number of Cycles > 20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Typical Test Results Environmental Test Method Measurement Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 Salt Fog Test TR-NWT-001334 Circuit Resistance (mOhms) >10 Test 5.11 Strain Relief Clip Wire Cap Module Housing .71 18.06 .62 1.50 15.87 38.15 Dimensions are in inches. Dimensions in brackets are metric . WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2011 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com WW-COSP170 or by phone: 800-777-3300 and reference COSP170 5/2011