SmartZone Gateway-Enabled MSPO Series Rack PDU (for Aggregate and Per Outlet Power Monitoring with Switching) SPECIFICATION SHEET specifications Gateway-Enabled MSPO (Monitored and Switched Per Outlet) Series Rack Power Distribution Units (PDUs) safely and efficiently manage and distribute power to installed equipment and are available in a range of electrical and outlet configurations that cover all global regions. Multiple rack PDUs can be connected to the network via a SmartZone Gateway to provide local and remote monitoring of aggregate power, environmental and physical access data from a single IP address, enabling potential issues to be identified and under-utilized power capacity reclaimed. Gateway-Enabled MSPO Series Rack PDUs have remote switching capabilities, enabling individual outlets or a group of outlets to be switched on or off to reboot equipment or restrict unauthorized use of individual outlets. Power monitoring at the individual outlet level provides actionable management data on the power consumption of each connected IT device, enabling the redeployment or decommissioning of individual servers to reclaim available or under-utilized power capacity. Gateway-Enabled MSPO Series Rack PDUs integrate with comprehensive DCIM software platforms, to access current and historical trending information and event notification alarms. For more specialized applications, Panduit offers a custom made service which involves designing and manufacturing a rack PDU to meet exact customer specifications. technical information Dimensions: 32A or smaller vertical units: 70 H x 2.50 W x 2.36 D (1778mm x 64mm x 60mm) 50A or larger vertical units: 70 H x 3.25 W x 2.36 D (1778mm x 82mm x 60mm) Horizontal units: 1.73 H x 17.0 W x 8.84 D (44mm x 432mm x 225mm) Packaging: 3-meter or 10 foot long power cord, screws, and tool-less button mounting Mounting: Vertical rack PDUs provide multiple outlets and do not occupy any rack spaces Horizontal units mount via EIA 19 equipment mounting rails Amperage ratings: Global: 32 Amps US: 20, 30, and 60 Amps MSPO series rack PDU with gateway features and benefits Rack PDU Features Per outlet Provides actionable management data on the power consumption of each connected IT device enabling the power monitoring redeployment or decommissioning of individual servers to reclaim available or under-utilized power capacity Remote power Allows remote access to enable individual outlets or a group of outlets to be switched on or off to reboot equipment monitoring and or restrict unauthorized use of individual outlets switching controls Time Executes time delay sequencing of individual power outlets to avoid circuit overload due to the high in rush of current at delay sequencing equipment start up Aggregate Performs real-time monitoring and management of aggregate rack PDU current, voltage, kVA, kWhr, kW, Frequency and power monitoring Power Factor loads to monitor, document, and manage operational power utilization LCD digital display Displays a visible on-unit warning when the current draw of rack PDU is close to the maximum Amp draw levels, helping to quickly identify and resolve concerns and avoid risk of overloaded circuits Customizable Offers standard or customizable builds with single or three phase options, a range of current ratings, and different power configurations outlets that can be adapted for varying power requirements Gateway Features Environmental Monitors cabinet conditions such as temperature, humidity and airflow to facilitate capacity management and identify monitoring potential causes of equipment failure Single IP address Multiple Rack PDUs can be connected to the network via a SmartZone Gateway to provide local and remote monitoring of environmental, and physical access data from a single IP address Door access Utilizes SmartZone serial keypads or card readers to support physical access security control of cabinet doors and and control prevent unauthorized access to racks or cabinets (applies to the SmartZone Gateway EP064 and Gateway EPA126) Alarm thresholds Provides user-defined critical power, environmental, and security thresholds that will prompt alarm notifications to enable resolution for maximum uptime SmartZone Captures actionable power and environmental data that can be utilized by SmartZone Software to enable data Software integration center operational and energy efficiencies, capacity management, and resilience www.panduit.com SmartZone Gateway-Enabled MSPO Series Rack PDU (for Aggregate and Per Outlet Power Monitoring) applications The SmartZone Gateway-Enabled MSPO Series Rack PDU safely and efficiently manages and distributes power to multiple rack or cabinet devices via a single power connector. The SmartZone Gateway-Enabled MSPO Series Rack PDU can be deployed and utilized as part of a gateway-based system that utilizes a SmartZone Gateway to maintain the active intelligence, with the resulting management of multiple Rack PDUs from a single IP address via a web interface or SNMP. SmartZone Gateway-Enabled MSPO Series Rack PDUs have remote switching capabilities, enabling users to remotely access, configure, or manage units or manage individual or a group of outlets such as turning outlets off that are not in use. This prevents overloads or recycling power to locked-up equipment, minimizing costly downtime and travel times to service equipment. Per Outlet Monitoring determines if power distribution is accurate and individual servers to be identified as candidates for additional capacity, redeployment, or decommissioning, improving overall data center efficiency Gateway-Enabled Rack PDUs are available for order as standard off-the-shelf units for most common requirements, or as customized build configurations that are designed and manufactured to meet exact product requirements. Offered in a variety of horizontal and vertical mounting options that support simple flexible installations for Panduit Net-Access Cabinets, or 2- and 4-post racks. As part of a fully intelligent data center or DCIM solution, SmartZone Gateway-Enabled MSPO Series Rack PDUs capture rack PDU power and environmental data that can be used by SmartZone Software to more effectively manage and optimize operational efficiencies. test data Parameter Value Mounting Tool-less button style Upgradability Firmware upgradeable Gateway Connection RJ45 serial port Operating Temperature 50F to 104F (10C to 40C) Rated Voltage 208V Single Phase or Three Phase Delta, 230V Single Phase, 230/400V Three Phase WYE Rated Current Up to 60A AC Nominal Rated Frequency 48 to 62Hz 2