Web Site: www.parallax.com Office: (916) 624-8333 Forums: forums.parallax.com Fax: (916) 624-8003 Sales: sales parallax.com Sales: (888) 512-1024 Technical: support parallax.com Tech Support: (888) 997-8267 ELEV-8 Power Distribution Board ( 80361) The ELEV-8 Power Distribution Board (PDB) allows the user to interconnect the ELEV-8 v3 power sources and sinks in a compact yet high-capacity form-factor. Designed for use in the ELEV-8 v3 Quadcopter with 1 to 2 batteries and up to 4 additional peripheral (low power) devices, this board will keep your project well organized and energized Features Fully Assembled no soldering required Extra connections to power accessories Unique shape cleanly mounts and stacks with many multirotor components Accepts 3.5 mm bullet connectors that remove easily, yet provide high-capacity secure connections great for constantly evolving projects Reflow manufacturing process ensures all connectors are securely attached for superior electrical performance and mechanical strength Specifications Maximum current ratings: 60 amps continuous* 100 amps for 15 seconds peak* Voltage: 0-18 VDC Outer dimensions: 2.8 x 2.8 x 0.32 in (72 x 72 x 8.2 mm) Weight: 1.0 oz (28 g) Connectors: o (8 pair) 3.5 female bullet sockets (gold-plated copper) o (4) 3-Pin 0.1 right-angle header (center pin is positive, outer pins are negative) 2 Copper thickness: 4 oz/ft or 0.0056 inches (0.14 mm) on each side ROHS Compliant & Lead-Free *These ratings are approximate and are greatly affected by the specific operating parameters. The ELEV-8 Power Distribution Board is only rated for use within the ELEV-8 v3 Quadcopter, and in accordance with all safety and usage guidelines and instructions. Notice of Risk & Disclaimer of Liability NOTICE OF RISK. Use of the ELEV-8 Power Distribution Board (PDB) can at times involve substantial risk of injury, property damage, and other dangers. Dangers peculiar to such activities include, but are not limited to: electrical shock, electrical sparking & arcing, reversed polarity, electrical short, burns, fire, and explosion. By keeping and using this product, you assume these risks. DISCLAIMER OF LIABILITY: In no event shall Parallax Inc. be liable for any direct, indirect, punitive, incidental, special, or consequential damages, to property or life, whatsoever arising out of or connected with the use or misuse of our products. Your purchase or use of this product constitutes your agreement to hereafter assume full and total responsibility for your subsequent utilization of the ELEV-8 Power Distribution Board and you agree to defend, protect, save harmless, and indemnify Parallax Inc., its officers, and employees relative to your potential use and misuse of this product. Copyright Parallax Inc. ELEV-8 Power Distribution Board ( 80361) v1.0 2/9/2016 Page 1 of 3 Safety Warnings and Guidelines WARNING: ELECTRIC SHOCK HAZARD. Never contact (directly or indirectly, especially with a conductive object) any uninsulated or inadequately insulated components that may be energized (always assume everything is energized when power is connected). WARNING: HOT. Do not touch during or shortly after operation. The ELEV-8 Power Distribution Board may become hot during operation, which could cause damage to nearby property (especially if flammable or low melting point) or burn injuries. Always let your ELEV-8 Power Distribution Board cool down to room temperature before handling. This device has no mechanical or electrical protection to prevent reversed polarity. Always pay careful attention to polarity indicators on device. The user is responsible for any injury or damage caused by reversing the polarity of connected devices. Do not enclose or thermally isolate the ELEV-8 Power Distribution Board. It must be exposed to constant airflow or other cooling method, or else it may overheat, resulting in property damage or injury. The ELEV-8 Power Distribution Board has exposed terminals. It is the user s responsibility to adequately insulate all components to prevent electrical shorting and electrical shock Only use compatible and properly insulated connectors rated for high current supplied by Parallax. Do not use connectors that are loose-fitting, uninsulated, or inadequately rated for your application. KEEP DRY. Do not expose the ELEV-8 Power Distribution Board to wet or corrosive environments, extreme temperatures (below 0 C or above 50 C), flammable or volatile materials, impact or any other damage. Do not modify the ELEV-8 Power Distribution Board. This includes, but is not limited to, soldering, drilling, and cutting. Bill of Materials The ELEV-8 Power Distribution Board comes fully assembled from the following components: Part Quantity Description 300-80361 1 ELEV-8 Power Distribution Board Raw PCB 450-00053 16 3.5mm Bullet Connector Socket, Gold-Plated Copper 450-00150 4 3-Pin Right-Angle Header, 0.1 spacing, through-hole, solder bearing Additional Items Required Will vary with application. All items listed below are included with the ELEV-8 v3 Quadcopter Kit ( 80300) Power Adapter Cable, such as ELEV-8 EC3 to 3.5 Bullet Connector Power Cable ( 800-80300) Devices with 3.5mm Male Bullet Connectors, such as Parallax xRotor 20A ESC ( 750-90015) 3-Wire Extension Cables or 3-Pin Female Header w/ 0.1 pin spacing Safety Glasses ( 700-10003) Resources and Downloads Documentation (including the latest version of this document) and open-source design files are available from the ELEV-8 Power Distribution Board product page. Go to www.parallax.com and search 80361. Copyright Parallax Inc. ELEV-8 Power Distribution Board ( 80361) v1.0 2/9/2016 Page 2 of 3