Gold Plated Crocodile Probes Surface Mount Tweezer Probes Peak Part number: for Peak Atlas LCR - 2mm type for Peak Atlas LCR - 2mm Type PTPm electronic design ltd Probe Pack for Peak Atlas LCR First remove any probes that may already be attached to the First remove any probes that may already be attached to the Atlas LCR. You should then be left with the 2mm plugs on the end Atlas LCR. You should then be left with the 2mm plugs on the end (2mm connections) of the Atlas LCR test cable. of the Atlas LCR test cable. your plugs may both your plugs may both be black, that is ok. be black, that is ok. Now fully mate each plug of the LCR cable to the socket of each Now fully mate each plug of the LCR cable to the sockets of the croc cable. tweezer cable. To ensure that the probes characteristics are correctly Now, press and hold the Atlas LCR on-test button until the compensated within the Atlas LCR, we need to perform a simple following message is displayed: probe compensation procedure. This is very straightforward and we advise that you closely follow Probe Compensation This item is designed for the Atlas LCR this procedure for best results. and then: Please short the probes with 2mm plugs. You will need a short length of clean tinned-copper wire, about Now gently short the probes by bringing the tips together. 25mm (1 inch) in length, a lead clipped from a resistor will do. Dont press the tips together too hard, just enough for a If your Atlas LCR is fitted steady and secure contact. Place the short length of wire into the jaws with the 0.63mm square pin of each crocodile probe as illustrated: The Atlas LCR will then ask you to open the tweezers when it sockets then please Now allow the probes (and wire) to rest on has characterised the shorted tips. contact us for advice. a non-conducting surface so that there is no influence on the compensation. Now open the probes 0.63mm Sockets Now, press and hold the Atlas LCR on-test button until the 2mm Plugs following message is displayed: At this point, simply release the tweezers and wait for the Probe Compensation Atlas LCR to characterise the open circuit. and then: Please short the probes If the procedure is successful, the Tel. +44 (0) 1298 70012 As the probes are already shorted with your wire link the LCR will Atlas LCR will display OK and then Email: technical peakelec.co.uk shortly proceed to the next step. It will display: turn off. Post: Now open the probes Your new probes are now ready to Peak Electronic Design Ltd use. At this point, simply unclip the short length of wire from one of the West Road House probes and let the probes (and wire) rest on the table surface once again, try not to touch the wire or probes at this point. West Road If the procedure is successful, the Atlas LCR will Buxton display OK and then turn off. Your new probes are Derbyshire now ready to use. SK17 6HF, UKX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for peak manufacturer: Other Similar products are found below : ELSM IDT8A RJA11 UPS56 ATC55 UTP05 LLSM CRC01M CRC01 IDT8B IDT8C ATPK3 PAT02 LCD02 LCRLHP2 IDTN ENP90 ATC02 DCA75 LCR-40 ESR70