2E Indoor use only position switches Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin Protection degree: IP20 (terminals), IP40 (contacts) according to EN 60529 General data Ambient temperature: from -25C to +80C Version for operation in ambient temperature from -40C to +80 C on request 1 Max actuation frequency: 3600 operations cycles /hour 1 Mechanical endurance: 20 million operations cycles Maximum actuation speed: 0,5 m/s Minimum actuation speed: 1 mm/s (slow action) 0,01 mm/s (snap action) Driving torque for installation: see pages 7/1-7/12 (1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 60947- 5-1 standard. Main data Cross section of the conductors (flexible copper wire) ) Polymer housing with positive opening 2 Contact blocks 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 18, 37, 66, 67: min. 1 x 0,5 mm (1 x AWG 20) Protection degree IP20 (terminals), IP40 2 max. 2 x 2,5 mm (2 x AWG 14)) (contacts) 11 contact blocks available Actuator with plastic or metal push button Suitable for foot switches PA, PX series In conformity with standards: IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 60529, EN 60529, NFC 63-140, VDE 0660-200, VDE 0113, . Approvals: UL 508 Markings and quality marks: In conformity with requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and Electromagnetic Compatibility 2004/108/EC. Approval UL: E131787 Positive contact opening in conformity with standards: Approval CCC: 2013010305600704 IEC 60947-5-1, EN 60947-5-1, VDE 0660-206. Approval GOST: POCC IT.AB24.B04512 Installation for safety applications: Use only switches marked with the symbol . The safety circuit must always be connected with the NC contacts (normally closed contacts: 11-12, 21-22 or 31-32) as stated in the standard EN 60947-5-1, encl. K, par. 2. The switch must be actuated with at least up to the positive opening travel shown in the travels diagrams. The switch must be actuated at least with the positive opening force, shown in brackets, underneath each article, near the value of the min. force. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 7/1 to page 7/12. Electrical data Utilization categories Thermal current (Ith): 10 A Alternate current: AC15 (5060 Hz) Rated insulation voltage (Ui): 500 Vac 600 Vdc Ue (V) 250 400 500 Rated impulse withstand voltage (U ): 6 kV imp Ie (A) 6 4 1 Conditional shot circuit current: 1000 A according to EN 60947-5-1 Direct current: DC13 Protection against short circuits: fuse 10 A 500 V type aM Ue (V) 24 125 250 Pollution degree: 3 Ie (A) 6 1,1 0,4 Data type approved by UL Utilization categories Q300 (69 VA, 125-250 Vdc) A600 (720 VA, 120-600 Vac) Data of the housing type 1, 4X indoor use only, 12, 13 For all contact blocks use 60 or 75 C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm). In conformity with standard: UL 508 Please contact our technical service for the list of approved products. General Catalog 2013-2014 2/1792E Dimensional drawings Polymer push button Metal push button 29 29 Contacts type: 22 25.2 22 25.2 R = snap action 20 10 20 10 L = slow action = slow action LO overlapped LS = slow action shifted LV = slow action 8 8 shifted and spaced = slow action LA closer 27.2 27.2 Travel diagrams Contact blocks 2.2 4 0 6 R 1NO+1NC 1NO+1NC 5 VF B501 VF B502 1.1 3 0 1.5 6 L 1NO+1NC 1NO+1NC 6 VF B601 VF B602 3.4 4.6 0 3.1 6 LO 7 VF B701 1NO+1NC VF B702 1NO+1NC 1.6 4.4 0 2.9 6 L 2NC 2NC 9 VF B901 VF B902 0 1.4 6 L 2NO 2NO 10 VF B1001 VF B1002 4 0 2 6 R 11 VF B1101 2NC VF B1102 2NC 0.6 0 2.9 6 R 2NO 2NO 12 VF B1201 VF B1202 1.5 2.3 0 0.8 LV 2NC 2NC 13 VF B1301 VF B1302 3 4.5 6 2.9 1.4 LS 14 VF B1401 2NC VF B1402 2NC 0 3 4.5 6 0 1.4 LS 2NO 2NO 15 VF B1501 VF B1502 3 6 3 0 1.5 6 LA 1NO+1NC 1NO+1NC 18 VF B1801 VF B1802 2 0 3.4 4.9 6 L 37 VF B3701 1NO+1NC VF B3702 1NO+1NC 1.5 1.4 2.9 0 6 L 1NC 1NC 66 VF B6601 VF B6602 0 1.4 6 L 1NO 1NO 67 VF B6701 VF B6702 Max speed 0,5 m/s 0,5 m/s Min. force 8 N (20 N ) 8 N (20 N ) Legend Closed contact Opened contact Positive opening travel Pushing the switch / Releasing the switch Code structure article options VF B50VF B5011--GG Contact blocks Contacts type 5 1NO+1NC, snap action silver contacts (standard) 6 1NO+1NC, slow action 7 1NO+1NC, slow action overlapped G silver contacts gold plated 1 m 9 2NC, slow action 10 2NO, slow action 11 2NC, snap action Actuators 12 2NO, snap action 01 with polymer push button 13 2NC, slow action shifted and spaced 14 2NC, slow action shifted 02 with metal push button 15 2NO, slow action shifted 18 1NO+1NC, slow action closer 37 1NO+1NC, snap action 66 1NC, snap action 67 1NO, snap action Items with code on the green background are available in stock Accessories See page 6/1 All measures in the drawings are in mm General Catalog 2013-2014 2/180 39.7 4.4 35.8 20.8 56.6 39.7 4.4 35.8 20.8 56.6