D E L 4.75 0.8 1.5 C Y C E R E B General Emergency Medical Fire & Purpose Lighting Security FEATURES 6V 1.20 AH 20-hr. Absorbent Glass Mat (AGM) technology for PS-612 6V 1.12 AH 10-hr. superior performance Rechargeable Sealed Lead Acid Battery Valve regulated, maintenance free spill proof construction PS General Purpose Series Power/volume ratio yielding excellent energy density TERMINALS: (mm) Rugged vibration and impact resistant ABS case and cover F1: Quick disconnect tabs, 0.187 x 0.032 Mate with Gas recombination technology AMP. INC. FASTON 187 series 5 year design life 2.5 APPROVALS Approved for transport by air. D.O.T., I.A.T.A., F.A.A. 3.2 6.35 and C.A.B. certified U.L. recognized ISO9001:2015 Quality management systems Torque Not Applicable DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS Nominal Voltage 6 volts (3 cells) L: 3.82 (97) W: 0.94 (24) H: 2.00 (51) Nominal Capacity HT: 2.20 (56) 20-hr. (60mA to 5.25 volts) 1.20 AH Tolerances are +/- 0.04 in. 10-hr. (112mA to 5.25 volts) 1.12 AH W (+/- 1mm) and +/- 0.08 in. 5-hr. (202mA to 5.10 volts) 1.01 AH (+/- 2mm) for height dimensions. All data 1-hr. (730mA to 4.50 volts) 0.73 AH subject to change without notice. Approximate Weight 0.64 lbs. (0.29 kg) Internal Resistance (approx.) 65.0 milliohms Sealed Rechargeable Max Short-Duration Discharge Current (10 Sec.) 12.0 amperes Battery HT H Shelf Life (% of nominal capacity at 68F (20C) MODEL PS-612 6 Volt 1.4 Amp. Hr. 1 Month 97% Pb MH20845 Power-Sonic Corporation NONSPILLABLE 3 Month 91% 6 Month 83% L Operating Temperature Range Charge 5F (-15C) to 122F (50C) Discharge -4F (-20C) to 140F (60C) L: 3.82 (97) W: 0.94 (24) H: 2.00 (51) HT: 2.20 (56) CORPORATE HEADQUARTERS Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for POWER-SONIC EUROPE LIMITED Case ABS Plastic (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA EUROPE, MIDDLE EAST AND AFRICA) height dimensions. All data subject to change without notice. Power-Sonic Corporation 3 Buckingham Square, PSC-6300A-C 7550 Panasonic Way, San Diego, Hurricane Way, Wickford, Power Sonic Chargers PSC-6300-PC California 92154 Essex SS11 8YQ T: +1 (619) 661 2020 T: +44 (0)1268 560686 F: +1 (619) 661 3650 F: +44 (0)1268 560902 E: customer-service power-sonic.com E: salesEMEA power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E www.power-sonic.com T S U M Y R E T PS SERIES Rev1: 11/18 T A B6V 1.20 AH 20-hr. PS-612 6V 1.12 AH 10-hr. Rechargeable Sealed Lead Acid Battery PS General Purpose Series SHELF LIFE & STORAGE SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE LIFE CHARACTERISTICS IN STAND-BY USE 100 SHELF LIFE & STORAGE Charging is not necessary unless 100% of capacity 100 LIFE CHARACTERISTICS IN STAND-BY USE is required. Charging is not Ambient Temperature 20C (68F) necessary unless 100 80 o 100% of capacity Charging before 5 C is required. Ambient Temperature 20C (68F) use is necessary o 80 (41 F) to help recover 100 80 o full capacity. Charging before 5 C use is necessary 60 o 60 80 (41 F) to help recover full capacity. Float Charging Voltage 60 o o 40 o 60 30 C 40 C 20 C 2.25 - 2.30 V/Cell o o o (86 F) Float Charging Voltage 40 (104 F) (68 F) o 20 o o 40 40 C 30 C 20 C 2.25 - 2.30 V/Cell o o o (86 F) (104 F) 0 40 (68 F) 0 20 0 2 4 6 8 10 12 14 16 18 20 0 1 23 4 5 0 0 Years Standing Period (Months) 0 2 4 6 8 10 12 14 16 18 20 0 1 23 4 5 Years Standing Period (Months) CHARGING CHARGERS Cycle Applications: Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable 2.35v/c 2.45v/c (14.1 14.7v for 12v Monobloc) at 20C. for batteries with a variety of capacities. Initial charging current should be set at less than 0.25C Please refer to our website for more information on Amps. Switch to float charge to avoid overcharging. our switch mode and transformer type chargers. Float or Stand-By Service: Apply constant voltage Please contact our technical department for advice if charge of 2.25v/c 2.30v/c (13.5 to 13.8 volts for 12v you have difficulty in locating a suitable charger. Monobloc at 20C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully FURTHER INFORMATION charged condition. Please refer to our website www.power-sonic.com Temperature Compensation: Charging Voltage for both for a complete range of useful downloads, such as Cyclic and Standby applications should be regulated in product catalogs, material safety data sheets (MSDS), relation to ambient temperature. As temperature rises ISO certification, etc. charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications. APPLICATIONS General purpose Medical Emergency lighting Fire and security CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA EUROPE, MIDDLE EAST AND AFRICA) Power-Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way, San Diego, Hurricane Way, Wickford, California 92154 Essex SS11 8YQ T: +1 (619) 661 2020 T: +44 (0)1268 560686 F: +1 (619) 661 3650 F: +44 (0)1268 560902 E: customer-service power-sonic.com E: salesEMEA power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E www.power-sonic.com Capacity Retention Ratio (%) Capacity Retention Ratio (%) Retention Capacity (%) Retention Capacity (%) PS SERIES Rev1: 11/18