Mechanical L01 OEM Module Size: 40mm x 16mm x 2.7mm With LoRa, Wifi and BLE, the L01 OEM Module is the only Operating temperature: triple bearer MicroPython enabled micro controller on the -40 to 85 degrees celsius market today the perfect enterprise grade IoT plaorm ftf or your connected Things. With the latest Espressif chipset the L01 ESP32 Dual Core 8MB flash memory Microcontroller and oerff s a perfect combination of power, friendliness and flexibility. WiFi/Bluetooth 4.2 Create and connect your things everywhere. Fast. radio L01 Features - Powerful CPU, BLE and state of the art WiFi radio. 1KM Wifi Range - Can also double up as a Nano LoRa gateway - MicroPython enabled LoRa transceiver - Fits in a standard breadboard (with headers) - Ultra-low power usage: a fraction compared to other connected micro controllers Interfaces - 2 x UART, 2 x SPI, I2C, I2S, micro SD card Processing - Analog channels: 8x12 bit ADCs - Espressif ESP32 chipset - Timers: 4x16 bit with PWM and input capture - Dual processor + WiFi radio System on Chip. - DMA on all peripherals - Network processor handles the WiFi connectivity and the IPv6 - GPIO: Up to 24 stack. - Main processor is entirely free to run the user application. Security & Certifications Hash / encryption - An extra ULP-coprocessor that can monitor GPIOs, the ADC - SSL/TLS support SHA, MD5, DES, AES channels and control most of the internal peripherals during - WPA Enterprise security deep-sleep mode while only consuming 25uA. WiFi - FCC - 2AJMTL01XXX 802.11b/g/n 16mbps - CE Bluetooth Operating Frequencies Memory Low energy and classic - 868 MHz (Europe) at +14dBm maximum - RAM: 4MB RTC - 915 MHz (North and South America, Australia and New - Flash Memory: 8MB Running at 32KHz Zealand) at +20dBm maximum - Hardware floating point acceleration - Python multi-threading Range Specifiction - Node range: Up to 40km Power - Nano-Gateway: Up to 22km - Voltage Input: 3.3V regulated - Nano-Gateway Capacity: Up to 100 nodes - WiFi: 12mA in active mode, 5uA in standby - Lora: 15mA in active mode, 10uA in standby Use the Pymakr IDE Super easy code editor to write your Python scripts LoRa Specifiction Quick Verification - Semtech LoRa transceiver SX1272 For easy and fast debugging use the interactive shell that is - LoRaWAN stack accessible through telnet or one of the serial ports - Class A and C devices Easy Upload Upload your scripts, and any other files you want to the L01 via With dozens of ready to use templates and libraries soon to the FTP server be available on the Pycom Exchange, developing a new IoT Locally or remotely solution is now easier and faster. Reset the L01 (you can do it locally, or remotely via Telnet) Distributed and manufactured by Pycom Ltd. mechanical methods, without the prior written permission of Pycom Ltd, Registered office: except in the case of brief quotations embodied in critical reviews and High Point, 9 Sydenham Road, Guildford, Surrey GU1 3RX, UK certain other noncommercial uses permitted by copyright law. Copyright 2017 by Pycom Ltd. All rights reserved. No part of this document may be reproduced, distributed, or transmitted in any form or To order contact sales pycom.io by any means, including photocopying, recording, or other electronic or all non-transmitter functions the host manufacturer is responsible EU Regulatory Conformance for ensuring compliance with the module(s) installed and fully operational. For example, if a host was previously authorized as Hereby, Pycom Ltd declares that the radio equipment type L01 an unintentional radiator under the Declaration of Conformity OEM Module is in compliance with Directive 2014/53/EU. The full procedure without a transmitter certified module and a module is text of the EU declaration of conformity is available at the following added, the host manufacturer is responsible for ensuring that the internet address: www.pycom.io aerft the module is installed and operational the host continues to be compliant with the Part 15B unintentional radiator requirements Federal Communication Commission Interference Statement The module is limited to OEM installation ONLY. The module is limited to installation in mobile or fixed application. We hereby This device complies with Part 15 of the FCC Rules. Operation is acknowledge our responsibility to provide guidance to the host subject to the following two conditions: manufacturer in the event that they require assistance for ensuring compliance with the Part 15 Subpart B requirements. (1) This device may not cause harmful interference. (2) This device must accept any interference received, including IMPORTANT NOTE: In the event that these conditions cannot interference that may cause undesired operation. be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no CAUTION: Changes or modifications not expressly approved by the longer considered valid and the FCC ID cannot be used on the party responsible for compliance could void the user s authority to final product. In these circumstances, the OEM integrator will operate the equipment. be responsible for reevaluating the end product(including the transmitter) and obtaining a separate FCC authorization. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of End Product Labeling the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This transmitter module is authorized only for use in device where This equipment generates uses and can radiate radio frequency the antenna may be installed such that 20 cm may be maintained energy and, if not installed and used in accordance with between the antenna and users. The final end product must be the instructions, may cause harmful interference to radio labeled in a visible area with the following: Contains FCC ID: communications. However, there is no guarantee that interference 2AJMTL01XXX. The grantee s FCC ID can be used only when all will not occur in a particular installation. If this equipment does FCC compliance requirements are met. cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the userff is The following FCC part 15.19 statement has to also be available on encouraged to try to correct the interference by one or more of the the label: following measures: This device complies with Part 15 of FCC rules. Operation is subject - Reorient or relocate the receiving antenna. to the following two conditions: - Increase the separation between the equipment and receiver. (1) this device may not cause harmful interference and - Connect the equipment into an outlet on a circuit different from (2) this device must accept any interference received, including that to which the receiver is connected. interference that may cause undesired operation. - Consult the dealer or an experienced radio/TV technician for help. Manual Information to the End User RF Warning Statement The OEM integrator has to be aware not to provide information to To comply with FCC RF exposure compliance requirements, the the end user regarding how to install or remove this RF module in antennas used for this transmitter must be installed to provide a the users manual of the end product which integrates this module. separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna In the user manual of the end product, the end user has to be or transmitter. informed that the equipment complies with FCC radio-frequency This device is intended only for OEM integrators under the exposure guidelines set forth for an uncontrolled environment. following conditions: 1) The antenna must be installed such that 20 cm is maintained The end user has to also be informed that any changes or between the antenna and users, and modifications not expressly approved by the manufacturer could void 2) The transmitter module may not be co-located with any other the user s authority to operate this equipment. transmitter or antenna. The end user manual shall include all required regulatory As long as two conditions above are met, further transmitter test information/warning as show in this manual. will not be required. The maximum operating ambient temperature of the equipment However, the OEM integrator is still responsible for testing declared by the manufacturer is: -20~+85C their end-product for any additional compliance requirements required with this module installed. To ensure compliance with Receiver category 3