1
PUSHBUTTONS
LUMOTAST FK 1 - 3
LUMOTAST FK - Illuminated pushbuttons 1 - 7
LUMOTAST FK - Signal lamps 1 - 11
LUMOTAST 25 1 - 15
LUMOTAST 25 - Illuminated pushbuttons 1 - 19
LUMOTAST 25 - Selector switches 1 - 24
LUMOTAST 25 - Keylock switches 1 - 26
LUMOTAST 25 - Emergency stop pushbuttons 1 - 29
LUMOTAST 25 - Signal lamps 1 - 32
LUMOTAST 75 IP40 1 - 35
LUMOTAST 75 IP40 - Illuminated pushbuttons 1 - 37
LUMOTAST 75 IP40 - Keylock switches 1 - 42
LUMOTAST 75 IP40 - Signal lamps with lamp socket T 4.5 1 - 45
1 - 49
LUMOTAST 75 IP65
LUMOTAST 75 IP65 - Illuminated pushbuttons 1 - 51
LUMOTAST 75 IP65 - Signal lamps 1 - 57
1 - 63
Other keylock switches
Keylock switches 1 - 65
Priority keylock switches 1 - 68
1 - 73
Other pushbuttons
Pushbuttons non-illuminated - mounting hole diameter 9.1 mm 1 - 75
Pushbuttons illuminated - mounting hole diameter 9.1 mm 1 - 77
Pushbuttons non-illuminated - mounting hole diameter 15.2 mm 1 - 79
Pushbuttons non-illuminated - mounting hole diameter 16.2 mm 1 - 81
Pushbuttons non-illuminated - mounting hole diameter 18.2 mm 1 - 83
Pushbuttons illuminated - mounting hole diameter 20.3 mm, BA9s 1 - 85
LUMOTAST 22 - E-Stop, mounting hole diameter 22.3 mm 1 - 87
- NEW -PUSHBUTTONS
GENERAL INFORMATION
Concepts
1. Momentary pushbuttons are switching elements which 3. Illuminated pushbuttons have the same functions as
are used for making or breaking contact while they are described for (1) and (2) and feature an additional lamp
being pressed. socket for accomodating a filament, neon lamp or LED.
1
2. Latching pushbutton are used for making or breaking 4. L egending can ce effected using kabel holders, legend
contact until they are returned to their initial position inserts, by engraving or hot stamping. Grooved trans-
by being pressed again. parent lenses are not suitable for legending.
CE-Conformity
The products of the Chapter Pushbuttons can relating All products with an operating voltage < 50 V
to the CE-conformity according to the Low-Voltage For these products no directive applies.
Directive 73/23/EWG be divided into the following
groups: Single parts, accessories and illumination
For these products no directiveapplies.
Emergency-stop components with an operating EMC-Law
voltage < 50 V The components of this catalogue are within the meaning
F. ex. LUMOTAST 25 emergency-stop. For this pushbutton of the law concerning the Eletromagnetic Conformy
the Machine Directive 89/392/EWG applies. (= EMC-Law)basic components as, f. ex., switches,
signal lamps or lik and, therefore, do not fall within the
All products with an operating voltage > 50 V scope of the EMC-Law.
For these elements the Low-Voltage Directive 72/23/EWG
applies.
Marking
The marking will be corresponding to the Low-Voltage
Directive 73/23/EWG resp. the DirectiveCE-Marking
93/68/EW either on the packing or on the product itself.
1-2