C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r Qualified with 65kV/s Vcommon mode =1KV Features EN61010 for test, measurement and lab use EN60601 for medical applications DC/DC Converter Reinforced isolation 6.4kVDC or 8kVDC Unregulated Optional continuous short circuit protection Unique reinforced isolation transformer system Converters RxxPxx/R /X2 option for >9mm input/output clearance Description 1 Watt The RxxPxxS D Series of DC/DC Converters are certified to UL/CSA60950-1. This makes them ideal for 3 SIP7 safety applications where approved or reinforced isolation is required. The reinforced versions are also EN61010-1 certified for Lab Equipment Safety. Single and Dual Output Selection Guide Part nom. Input Output Output Efficiency max. Capacitive (1) (2) Number Voltage Voltage Current typ. Load VDC VDC mA % F (3,4,5) RxxP3.3S/R 5, 12, 15, 24 3.3 303 70 - 80 2200 (3,4,5) RxxP05S/R 5, 12, 15, 24 5 200 75 - 80 1000 (3,4,5) RxxP09S/R 5, 12, 15, 24 9 111 75 - 82 1000 (3,4,5) RxxP12S/R 5, 12, 15, 24 12 84 75 - 82 470 (3,4,5) RxxP15S/R 5, 12, 15, 24 15 66 75 - 83 470 (3,4,5) RxxP3.3D/R 5, 12, 15, 24 3.3 151 72 - 79 1000 (3,4,5) RxxP05D/R 5, 12, 15, 24 5 100 75 - 82 470 (3,4,5) RxxP09D/R 5, 12, 15, 24 9 55 75 - 82 470 (3,4,5) RxxP12D/R 5, 12, 15, 24 12 41 75 - 82 220 (3,4,5) RxxP15D/R 5, 12, 15, 24 15 33 75 - 83 220 22++ RoHSRoHS REACHREACH compliantcompliant compliantcompliant 10 from 1010 from 10 Notes: Note1: Efficiency is tested at nominal input and full load a t +25C ambient Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter E314885 Model Numbering UL/CSA60950-1 certified IEC/EN60950-1 certified UL/ES/CSA60601-1 certified R P /P/X2/R IEC/EN60601-1 certified (3) Reinforced Isolation Input Voltage IEC/EN61010-1 certified CB report (4) Pinout Output Voltage (5) Protection Single or Dual Notes: Note3: add suffix /R6.4 for 6.4kVDC/1second isola tion or /R8 for 8kVDC/1second isolation Note4: add suffix /X2 for single output with alterna tive pinout Note5: add suffix /P for continous short circuit protection Ordering Examples: REF dv/dt R05P3.3S/R8/P = 5V Input, 3.3V Output, Single Output, 8kVDC/1s isolation, Continous Short Circuit Protection DESIGN ADVISORY REPORT R24P05S/R6.4/P/X2 = 24V Input, 5V Output, Single Output, 6.4kVDC/1s isolation, Continous SCP, Alternative Pinout available AVAILABLE R12P05D/R8/X2 = 12V Input, 5V Output, Dual Output, 8kVDC/1s isolation, Alternative Pinout www.recom-power.com/eval-ref-boards www.recom-power.com/bier www.recom-power.com REV.: 6/2020 ECO-1 O O P P E a C C R R O O Y M M n D D O O U U t C C C C E E y T T R R S STypical Load Line RxxPxx/R DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 10% Minimum Load 0% Internal Operating Frequency 20kHz 50kHz 85kHz Output Ripple and Noise 20MHz BW 200mVp-p Efficiency vs. Load RxxP05S/R6.4 and RxxP05S/R8 RxxP05D/R6.4 and RxxP05D/R8 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 R05P05S R05P05D R12P05S R12P05D 10 10 R24P05S R24P05D 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % REGULATIONS Parameter Condition Value Output Accuracy 5.0% max. Line Regulation low line to high line, full load 1.2%/1% of Vin typ. 3.3Vout, 5Vout 15% typ. (6) Load Regulation 10% to 100% load 9Vout, 12Vout, 15Vout 10% typ. Notes: Note6: Operation below 10% load will not harm the converter, but specifications may not be met Tolerance Envelope +10% +5% +5% Vnom -1.5% -5% 10 50 100 Load % continued on next page www.recom-power.com REV.: 6/2020 ECO-2 Efficiency % Output Voltage % Efficiency %