Fully RoHS 6/6 Conform
ECONOLINE
Features
Full Power at 100C Ambient Temperature
DC/DC-Converter
1kVDC and 3kVDC Isolation Options
Unregulated
with 3 year Warranty
/H Version Certified for Medical Applications
Converters UL/EN/CSA Certified, CB Report
Suitable for Fully Automated Assembly
(including Vapor Phase Soldering)
Optional Continuous Short Circuit Protection
Efficiency to 85%
2 Watt
Built-In EN55022 Class A Filter
SMD Single &
The R2S and R2D converters are of the enclosed open frame type, meaning that they are
Description
un-potted. The converters are typically used in general purpose and industrial low power
isolation and voltage matching applications where an SMD converter is required.
Dual Output
The converter series feature an extended ambient temperature operating range of
-40C to +100C without derating and optional continuous short circuit protection.
In addition to two isolation options and three different case formats, the converters are also
available prepacked as tape and reel for use with automatic insertion machines.
Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
(1)
SMD (3kV) (VDC) (VDC) (mA) (%) Load
R2S**-xx3.3 (H) 5, 12, 15, 24 3.3 606 70-75 3300F
R2S**-xx05 (H) 5, 12, 15, 24 5 400 76-84 1200F
R2S**-xx09 (H) 5, 12, 15, 24 9 222 76-84 1200F
RoHS
2011/65/EU
E358085
6/6
R2S**-xx12 (H) 5, 12, 15, 24 12 167 76-85 680F
R2S**-xx15 (H) 5, 12, 15, 24 15 133 76-85 680F
UL-60950-1 Certified
R2S**-xx24 (H) 5, 12, 15, 24 24 83 76-85 220F
EN-60950-1 Certified
R2D**-xx05 (H) 5, 12, 15, 24 5 200 75-80 470F
EN-60601-1 Certified*
(*/H suffix)
R2D**-xx09 (H) 5, 12, 15, 24 9 111 75-80 470F
R2D**-xx12 (H) 5, 12, 15, 24 12 83 75-83 330F
R2D**-xx15 (H) 5, 12, 15, 24 15 66 75-85 330F
R2S-R2D
R2D**-xx24 (H) 5, 12, 15, 24 24 42 75-85 330F
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix P for Continuous Short Circuit Protection, e.g. R2S-0505/P, R2D-0505/HP
* add suffix -R for tape&reel packing e.g. R2S-0505-R. For more details see Tapes Section.
Derating-Graph
Case and Pinning Options (note restrictions on /H option)
(Ambient Temperature)
R2S** : ** without marking denotes 5 pins out of 8 fitted (/H option available)
** with marking 8 denotes 8 pins out of 8 fitted (/H option not available)
** with marking 12 denotes 10 pins out of 12 fitted (/H option available)
R2D** : ** without marking denotes 6 pins out of 10 fitted (/H option available)
** with marking 10 denotes with 10 pins out of 10 fitted (/H option not available)
** with marking 12 denotes with 10 pins out of 12 fitted (/H option available)
!
Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up)
A
Input Voltage Range 10%
Output Voltage Accuracy 5%
Line Voltage Regulation 1.2%/1% of Vin max.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
***Any data referred to in this datasheet are of indicative nature
9V, 12V, 15V, 24V output types 10% max.
and based on our practical experience only. For further details,
please refer to our Application Notes.
Output Ripple and Noise (20MHz limited) 150mVp-p max.
Operating Frequency 20kHz min. / 40kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 80% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
continued on next page
Refer to Application Notes
www.recom-power.com REV: 0/2015 E-85
}
R2S & R2D
ECONOLINE
DC/DC-Converter
Series
Specifications - Continued
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute***) 500VAC / 60Hz
Isolation Voltage (tested for 1 second) 3000VDC
(rated for 1 minute***) 1500VAC / 60Hz
Isolation Capacitance 115pF max.
Isolation Resistance (Viso 500V) 10 G min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40C to +100C (see Graph)
Storage Temperature Range -55C to +125C
Reflow Temperature ROHS compliant 245C (30 sec), peak 255C (5 sec) max.
Vapor Phase Process (for more details see Application Notes) 230C (90 sec) max.
Relative Humidity 95% RH
Package Weight R2S, R2S8 1.4g
R2D, R2D10 1.5g
R2S12, R2D12 1.6g
Packing Quantity R2S, R2S8 39 pcs per Tube
R2S12, R2D, R2D10, R2D12 33 pcs per tube
All Types 250 pcs per Reel
3
MTBF (+25C) using MIL-HDBK 217F 886 x 10 hours
Detailed Information see
3
(+85C) Application Notes chapterMTB using MIL-HDBK 217F 128 x 10 hours
Certifications
CB Test Report Report: US/14402/UL
UL General Safety Report: E358085 UL 60950-1 2nd Ed.
CUL General Safety C22.2 No. 60950-1-03
EN Medical Safety Report: MDD1205098-2 + RM1205098-2 IEC/EN 60601-1 3rd Ed.
Medical Report + ISO14971 Risk Assessment
EN General Safety Report: SPCLVD 1211033-3 EN60950-1: 2006 + A12:2011
Conducted / Radiated Emissions EN55022 Level A
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Typical Characteristics
3 +
+4%&' #
$%&'
(
(
(
(
(
R2S-xx05
(
(
(
*+
*+
3 +
+4%&' #
$%&'
(
(
(
(
R2D-xx05 (
(
(
(
*+
*+
E-86 REV: 0/2015 www.recom-power.com
R2S-R2D
3 +
+4
3 +
+4
#
$ )*
#
$ )*