C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r Universal input 85-264VAC Features <250mW No load power consumption AC/DC Converter -25C to +80C Operating temperature, with derating Class II installations (without FG) Regulated Continuous SCP, OCP Converter IEC/EN/UL60950 & IEC/EN/UL62368 certified RAC02-GBRAC02-GB Description 2 Watt 3 The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, Single board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit-proof isolated DC outputs, low standby power consumption and -25C to +80C Output operating temperature range. The RAC02-GB have a built-in Class B / FCC Part 15 EMC filter, are certified to EN60950 and EN62368 safety standards and come with a three year warranty. EMC Class B Selection Guide Part Input Output Output Efficiency Max. Capacitive (1) Number Voltage Range Voltage Current typ Load VAC VDC mA % F RAC02-3.3SGB 85-264 3.3 500 63 500 RAC02-05SGB 85-264 5 400 63 500 RAC02-12SGB 85-264 12 167 68 200 RAC02-15SGB 85-264 15 140 63 200 RAC02-24SGB 85-264 24 83 63 200 22 ++ Notes: RoHSRoHS REACHREACH compliantcompliant compliantcompliant 10 from 1010 from 10 Note1: Measured with all input voltages at +25C with constant resistant mode at full load E196683 Model Numbering ULIEC/EN60950-1 certified RAC02- SGB UL/IEC/EN62368-1 certified EMC Class B nom. Output Power CAN/CSA-C22.2 No. 62368 certified IEC/EN62368-1 certified Single nom. Output Voltage CB Report Ordering Examples: RAC02-12SGB 12Vout Single Output EMC Class B www.recom-power.com REV.: 3/2019 PA-1 O O P P E a C C R R O O Y M M n D D O O U U t C C C C E E y T T R R S SRAC02-GB AC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi-type (2,3,4) Input Voltage Range nom. Vin = 230VAC 85VAC 230VAC 264VAC 115VAC 50mA Input Current 230VAC 30mA 115VAC 30A Inrush Current cold start at +25C 230VAC 40A No load Power Consumption 180mW 250mW Input Frequency Range 47Hz 63Hz Minimum Load 0% 115VAC 0.55 Power Factor 230VAC 0.42 115VAC 250ms 2s Start-up Time 230VAC 200ms 2s 115VAC 20ms Hold-up time 230VAC 80ms Internal Operating Frequency 100% load at nominal Vin 65kHz 3.3Vout 100mVp-p 5Vout 100mVp-p 12Vout 200mVp-p 0C to 80C 15Vout 200mVp-p 24Vout 240mVp-p Output Ripple and Noise 20MHz BW 3.3Vout 200mVp-p 5Vout 200mVp-p -25C to 0C 12Vout 300mVp-p 15Vout 300mVp-p 24Vout 300mVp-p Notes: Note2: No proper operation with DC input voltage Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to Line Derating Efficiency vs. Load RAC02-05SGB RAC02-12SGB 100 100 90 90 80 80 70 70 60 60 50 50 115VAC 115VAC 40 40 230VAC 230VAC 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % www.recom-power.com REV.: 3/2019 PA-2 Efficiency % Efficiency %