NOT RECOMMENDED FOR NEW DESIGNS Ultracompact AC-DC Power Supply POWERLINE Features 4 Watt PCB Mount Package AC/DC-Converter Universal Input Voltage Range including 277VAC Regulated with 3 year Warranty 3kVAC Isolation (Class II) Very Low No Load Input Current Converters Dual output version for standby relay circuits Short Circuit Protected EN/UL Certified, CE Marked. Selection Guide Part Input Output Output Efficiency Max 4 Watt Number Range (VAC) Voltage Current Capacitive (Std) (/277) (VDC) (mA) (%) Load Single/Dual 90-305 RAC04-05SA * 90-264 5 800 72 8000F RAC04-12SA * 90-264 90-305 12 333 76 1000F Output RAC04-24SA 90-264 90-305 24 167 77 220F * add suffix /277 for 90-305VAC input. High input voltage converters are identified by omitting pin 1. th NRND (Last time buy: 30 Oct 2020) Part Input Output Output Efficiency Max Number Range (VAC) Voltage Current Capacitive (Std) (/277) (VDC) (mA) (%) Load 90-305 RAC04-3.3SA 90-264 3.3 1200 68 14000F RAC04-09SA 90-264 90-305 9 444 75 2400F RoHS RAC04-15SA 90-264 90-305 15 267 76 700F 2011/65/EU 6/6 RAC04-0512DA 90-264 90-305 5/12 120/250 75 4700/330F E196683 Specifications (typical at 25C and after warm up time unless otherwise specified ) EN 55022/55024 Certified Input Voltage Range standard 90-264VAC or 120-370VDC UL-60950-1 Certified /277 versions 90-305VAC or 120-430VDC Rated Power 4 Watts max Input Frequency Range (for AC Input) 47-440Hz Input Current (full load) 115/230VAC 95/65mA max. RAC04-A /277 75/55mA max. No Load Power Consumption 115/230/277VAC 150/210/220mW typ. Inrush Current (<0.5ms) 115/230VAC 15/25A max. Leakage Current 0.25mA max Output Voltage Accuracy (full load) single outputs 2% 3.3V (/277 Version) 0.5% Dual output version 5V/12V 5%/2% Line Voltage Regulation (low line, high line at full load) 0.2% typ Dual output version 5V/12V 3%/0.2% typ Derating Graph Load Voltage Regulation 3.3V output 1% typ ( 0% to 100% full load ) All others 0.5% typ (Ambient Temperature) Dual output version 5V/12V 5%/0.5% typ Output Ripple and Noise 3.3V output <250mVp-p max (measured 20MHz of bandwidth with 5V output <200mVp-p max. 0.1F & 47F parallel capacitor) All others 100mVp-p max Operating Frequency 132kHz typ Hold-up time 15ms min. < - 6 ( Minimum Load single outputs 0% 6 6 6 1 5V/12V 25% % 6 % 6( RMS Isolation Voltage (input to output) 3kVAC / 1minute 6 6 Temperature Coefficient 0.02%/C typ Isolation Resistance 100 M max Short Circuit Protection Hiccup, Automatic Restart Output Overvoltage Protection Zener Clamping Diode Operating Temperature Range All others -40C to +70C (natural convection, with derating) Dual output version -40C to +70C Storage Temperature Range -40C to +85C Humidity 95% RH max Refer to Application Notes continued on next page PA-14 REV: 3/2020 www.recom-international.com TH LAST TIME BUY: 30 OCT 2020, 3.3SA, 09SA, 15SA, 0512DA TH LAST TIME BUY: 30 OCT 2020, /277 VERSION EXCEPT 05 & 12 VOUT RAC04 RAC04 TH LAST TIME BUY: 30 Oct 2020, 3.3SA, 09S, 15SA, 0512DA TH NOT RECOMMENDED FOR NEW DESIGNS LAST TIME BUY: 30 OCT 2020, /277 VERSION EXCEPT 05 & 12VOUT DESIGNS RAC04-SA POWERLINE Series AC/DC-Converter Specifications (typical at 25C and after warm up time unless otherwise specified ) Case Material Epoxy with Fibreglass (UL94V-0) Package Weight 26g Packing Quantity 12 pcs EMC Conducted and Radiated EN 55022 Class B Noise Immunity EN 55024 3 MTBF (+25C) using MIL-HDBK-217F >350 x 10 hours Typical Characteristics :.. 0 09 ( + 3 :.. 0 09 ( 6 - 4 -- + 3 8 8 ( 8 8 ( - 0 6 - 6 Standard Package Style and Pinning % % % Pin Dual Output /277 Versions % 1 NC NC No Pin 2 same % % 3 -VDC out Com same 4 NC same % % % 5 AC in (L) AC in (L) AC in (L) 6 % % % 7NC NC NC . 7 % NC = No Connection % % A % % XX.X 0.5 mm % XX.XX 0.25 mm It is recommended to additionally bond the /277 version of the converter to the PCB if the application is subject to vibration or mechanical shock. Standard Application Circuit Standby Relay Application + 6 + 6 With 110VAC supply and 10mA 4 1 - 9 6 standby load, the circuit consumes typically only 150mW. 0 , 6 2 6 Once activated by the remote - 0 2 handset, the standard 12V relay can switch a 16A load. 1 + 6 + 6 Compact single output regulated 4 1 power supply - - % 4 4 + 3 6 6 Suggested fuse rating: 6 2 6 2 1A Slow Blow The product information and specications may be subject to changes even without prior written notice.The product has been designed for various applications its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOMs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its afliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PA-15 www.recom-power.com REV: 3/2020 Pin Connections Single Output +VDC out +12V +5V V V V VAC in (N) VAC in (N) VAC in (N) :.. 0 09 :.. 0 09